Summary

양적, 피부가 상처 관리를위한 등각 피부와 같은 전자 시스템의 제조 및 특성

Published: September 02, 2015
doi:

Summary

This article presents methods to fabricate and characterize a conformal, skin-like electronic system and protocols for the use in clinical applications, particularly on cutaneous wound management.

Abstract

Recent advances in the development of electronic technologies and biomedical devices offer opportunities for non-invasive, quantitative assessment of cutaneous wound healing on the skin. Existing methods, however, still rely on visual inspections through various microscopic tools and devices that normally include high-cost, sophisticated systems and require well trained personnel for operation and data analysis. Here, we describe methods and protocols to fabricate a conformal, skin-like electronics system that enables conformal lamination to the skin surface near the wound tissues, which provides recording of high fidelity electrical signals such as skin temperature and thermal conductivity. The methods of device fabrication provide details of step-by-step preparation of the microelectronic system that is completely enclosed with elastomeric silicone materials to offer electrical isolation. The experimental study presents multifunctional, biocompatible, waterproof, reusable, and flexible/stretchable characteristics of the device for clinical applications. Protocols of clinical testing provide an overview and sequential process of cleaning, testing setup, system operation, and data acquisition with the skin-like electronics, gently mounted on hypersensitive, cutaneous wound and contralateral tissues on patients.

Introduction

임상 연구 및 생물 의학 연구에서, 상처 치유의 모니터링은 상처 1,2의 조직 형태 학적 변화의 조직 학적 평가를 기반으로하는 침습적 방법에 초점을 맞추고있다. 최근, 전자 기술의 급속한 발전을 육안 또는 디지털 촬상 3,4- 공 초점 주사 현미경 및 분광기를 통해 프로세스 4,5- 상처 치유를 검사 할 수 고정밀 영상 및 분석 도구의 개발을 가능하게한다. 그러나, 이러한 접근법은 촬상 높은 비용, 복잡한 광학 도구 및 조작이 필요하며, 더욱 중요하게는, 환자는 시험 중에 고정화 할 필요가있다. 따라서,보다 정확한 상처 관리를 제공하기 쉬운, 비 침습성 정량 저렴하고있는 새로운 다기능 장치 및 시스템에 대한 요구가 존재한다.

여기서는 온도 및 열 condu 정확한 실시간 매핑을 제공 피부 같은 전자 시스템을 소개ctivity과 비 침습적 장치의 등각 적층 통하여 상처 부위에서 가열의 정확한 수준을 제공한다. 이 장치는 표피 6-9의 기술, 기계 및 재료 특성에 맞도록 설계되어 피부 표피 장착형 전자 시스템 (굽힘 강성, 총 두께, 유효 계수, 질량 밀도)의 클래스를 나타낸다.

이 장치는 생체 적합성, 피부 친화적 인, 방수 설계, 세척 환자 (10)에 임상 응용 프로그램에 대한 소독 할 수있는 재사용 가능한 형태이다. 상처 조직 근처에 장착 등각 전자 장치는 수분에 상관 온도 (8)와 열 전도율 (13)의 양적 기록을 통해, 상처 11,12 증가 혈류량과 효소 반응에 의한 염증 단계 (상처 치유 과정의 하나), 캡처 . 실험 및 계산 연구 accommod하는 역학 최적 설계를 결정자연의 움직임을 먹고 기계 파괴하지 않고 균주를 적용하고 고 충실도 신호의 획득을 제공하는 피부 표면에 등각 라미네이트 피부와 같은 전자 기계 스트레칭의 기본 물리학을 캡처합니다.

이 문서에서 설명하는 프로토콜은 장치 청소, 임상 설정에서 장비 설정 및 피부 상처에 온도와 열전도도의 정량적 모니터링을위한 임상 응용 프로그램을 포함하여 준비 테스트, 피부와 같은 전자 시스템에 대한 마이크로의 방법을 제시한다.

Protocol

장치 제조, 피부 적층, 및 특성에 대한 실험은 그림 1, 2에 나타낸, 4 버지니아 커먼 웰스 대학 (VCU), 리치몬드, 버지니아, 미국에서 바이오 인터페이스 나노 공학 연구실에서 수행이 자원 봉사자 모두를 포함했다. 이 연구는 VCU 임상 시험 심사위원회의 승인 (프로토콜 번호 : HM20001454)와 VCU 인간 연구에서 연구 지침을 따랐다. 임상 시험 심사위원회, 노스 웨스턴 대학, 시카고…

Representative Results

도 1은 환자에 양적, 피부 상처 관리 용으로 설계된 공형, 피부와 같은 전자 시스템의 특성의 개요를 나타낸다. 다기능 전자 장치는 마이크로 프랙탈 구조 3,14 구성 및 필라멘트 뱀 뛰어난 기계적인 신축성과 굽힘 성을 제공하는 얇은 탄성 중합체 막에 9,17 추적합니다. 완전히 실리콘 층에 의해 둘러싸인 호환 장치 혼자 반 데르 발스 상호 작용을 통해 피부에 부드러운,…

Discussion

This article highlights the methods and protocols to fabricate a conformal, skin-like electronics system that enables conformal lamination near the wound tissues, which offers quantitative measurement of skin temperature and thermal conductivity mapping on the skin.

The key features include the utilization of novel techniques of materials transfer printing and hard-soft materials integration to design and develop the flexible/stretchable, soft electronic device. The use of biocompatible, elec…

Disclosures

The authors have nothing to disclose.

Acknowledgements

이 작품은 공학부, 버지니아 커먼 웰스 대학과 전자 장치의 일부 라이트 버지니아 마이크로 일렉트로닉스 센터의 미세 시설에서 제조되었다에서 시작 기금에 의해 지원되었다. 우리는 게시 된 기사 (10)로부터 획득 장치 및 임상 데이터 (이 논문의 그림 3 및 5)에 대한 공헌을 한 연구자를 인정합니다. 주문 제작, 데이터 기록 소프트웨어 W.-HY 덕분 요시아키 핫토리.

Materials

3" Silicon wafer University Wafer, USA N/A Use as carrier to fabricate the device
Acetone Fisher Scientific, USA A18-1 Use to clean a wafer and to remove photoresist
Isopropanol (IPA) Fisher Scientific, USA A459-1 Use to clean a wafer
AZ4620 photoresist AZ Electrionic Materials, USA N/A Use to make patterns on metals and polymers
AZ400K developer AZ Electrionic Materials, USA N/A Use to develop AZ4620 photoresist
Chromium etchant Transene, USA 1020AC Use to etch Cr layer of device
Copper etchant Transene, USA ASP-100 Use to etch Cu layer of device
Sylgard 184 Silicone Elastomer Kit (PDMS) Dow Corning, USA 39100000 Use as a substrate for 'dry' retrieval
PI2545 polyimide HD MicroSystem, USA N/A Use to encapsulate metal layer
Solaris Smooth-On, USA N/A Use as substrate and to encapsulate device
Petridish Carolina, USA 741255 Use as mold to make substrate
Water-Soluble Wave Solder Tape 5414 3M, USA AM000000217 Use to retrive device from PDMS layer
High Activity Liquid Stainless Steel Flux Worthington, USA 331929 Use to remove oxidation layer on Cu
Flexible, micro-film cable Elform, USA N/A (customized) Use to make the electrical connection between the electronic device and the data acquisition system
pH Neutral Cleaner Australian Gold, USA N/A Use as disinfectant solution to clean device in clinical testing
Solder Kester, USA 24-6337-9703 Use as material to solder hard wires
Ultraviolet lamp Cole-Parmer, USA 97600-00 Use to activate PDMS layer as hydrophilic surface
Multiplexer FixYourBoard, USA U802 Use to acquire measurements from six sensing components 
DC/AC current source Keithley, USA 6221 Use to supply current
SMD Digital Hot Air Rework Station Aoyue, China 968A+ Use to solder hard wires, to electrically connect between the device and external instruments
Infrared camera FLIR, USA 435-0001-01-00 Use to take infrared images in experiment
Digital multimeter Fluke, USA 117 Use to check electrical connection
Lock-in amplifier Stanford Research System, USA SR830 Use to perform four-point-probe-measurement
Electron beam evaporator 9 scale Vacuum Products, USA N/A (customized) Use to deposit thin films (Cu and SiO2)

References

  1. Dargaville, T. R., et al. Sensors and imaging for wound healing: A review. Biosens Bioelectron. 41, 30-42 (2013).
  2. Panuncialman, J., Hammerman, S., Carson, P., Falanga, V. Wound edge biopsy sites in chronic wounds heal rapidly and do not result in delayed wound healing. J Invest Dermatol. 129, S47-S47 (2009).
  3. Hess, C. T., Kirsner, R. S. . Orchestrating Wound Healing: Assessing and Preparing the Wound Bed. Adv Skin Wound Care. 16 (5), 246-257 (2003).
  4. Lange-Asschenfeldt, S., et al. Applicability of confocal laser scanning microscopy for evaluation and monitoring of cutaneous wound healing. J Biomed Opt. 17 (7), (2012).
  5. Crane, N. J., Elster, E. A. Vibrational spectroscopy: a tool being developed for the noninvasive monitoring of wound healing. J Biomed Opt. 17 (7), (2012).
  6. Jeong, J. W., et al. Materials and Optimized Designs for Human-Machine Interfaces Via Epidermal Electronics. Adv Mater. 25 (47), 6839-6846 (2013).
  7. Kim, D. H., et al. Epidermal Electronics. Science. 333 (6044), 838-843 (2011).
  8. Webb, R. C., et al. Ultrathin conformal devices for precise and continuous thermal characterization of human skin (vol 12, pg 938). Nat Mater. 12, 1078-1078 (2013).
  9. Yeo, W. H., et al. Multifunctional Epidermal Electronics Printed Directly Onto the Skin. Adv Mater. 25 (20), 2773-2778 (2013).
  10. Hattori, Y., et al. Multifunctional skin-like electronics for quantitative, clinical monitoring of cutaneous wound healing. Adv Healthc Mater. 3 (10), 1597-1607 (2014).
  11. Guo, S., DiPietro, L. A. Factors Affecting Wound Healing. J Dent Res. 89 (3), 219-229 (2010).
  12. Matzeu, G., et al. Skin temperature monitoring by a wireless sensor. Ieee Ind Elec. , 3533-3535 (2011).
  13. Cahill, D. G. Thermal-Conductivity Measurement from 30-K to 750-K – the 3-Omega Method. Rev Sci Instrum. 61 (2), 802-808 (1990).
  14. Fan, J. A., et al. Fractal Design Concepts for Stretchable Electronics. Nature Commun. 5 (3266), (2013).
  15. Song, Y. M., et al. Digital cameras with designs inspired by the arthropod eye. Nature. 497 (7447), 95-99 (2013).
  16. Jeong, J. W., et al. Capacitive Epidermal Electronics for Electrically Safe, Long-Term Electrophysiological Measurements. Adv Healthc Mater. 3 (5), 642-648 (2013).
  17. Zhang, Y. H., et al. Experimental and Theoretical Studies of Serpentine Microstructures Bonded To Prestrained Elastomers for Stretchable Electronics. Adv Funct Mater. 24 (14), 2028-2037 (2014).
  18. Carlson, A., Bowen, A. M., Huang, Y. G., Nuzzo, R. G., Rogers, J. A. Transfer Printing Techniques for Materials Assembly and Micro/Nanodevice Fabrication. Adv Mater. 24 (39), 5284-5318 (2012).
  19. Yeo, W. H., Webb, R. C., Lee, W., Jung, S., Rogers, J. A. Bio-integrated electronics and sensor systems. Proc Spie. 8725, (2013).
  20. Chung, H. J., et al. Fabrication of Releasable Single-Crystal Silicon–Metal Oxide Field-Effect Devices and Their Deterministic Assembly on Foreign Substrates. Adv Funct Mater. 21 (16), 3029-3036 (2011).
  21. Kim, H. S., et al. Unusual strategies for using indium gallium nitride grown on silicon (111) for solid-state lighting. Proc Natl Acad Sci U.S.A. 108 (25), 10072-10077 (2011).
  22. Padilla-Medina, J. A., et al. Assessment technique for acne treatments based on statistical parameters of skin thermal images. J Biomed Opt. 19 (4), 046019-046019 (2014).
check_url/53037?article_type=t&slug=fabrication-characterization-conformal-skin-like-electronic-system

Play Video

Cite This Article
Lee, W., Kwon, O., Lee, D. S., Yeo, W. Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management. J. Vis. Exp. (103), e53037, doi:10.3791/53037 (2015).

View Video