Summary

الكميات التعبير البروتين والتعاون التعريب عن طريق تعدد المناعية النسيجية تلطيخ والمتعددة الأطياف التصوير

Published: April 08, 2016
doi:

Summary

Immunohistochemistry is a powerful lab technique for evaluating protein localization and expression within tissues. Current semi-automated methods for quantitation introduce subjectivity and often create irreproducible results. Herein, we describe methods for multiplexed immunohistochemistry and objective quantitation of protein expression and co-localization using multispectral imaging.

Abstract

Immunohistochemistry is a commonly used clinical and research lab detection technique for investigating protein expression and localization within tissues. Many semi-quantitative systems have been developed for scoring expression using immunohistochemistry, but inherent subjectivity limits reproducibility and accuracy of results. Furthermore, the investigation of spatially overlapping biomarkers such as nuclear transcription factors is difficult with current immunohistochemistry techniques. We have developed and optimized a system for simultaneous investigation of multiple proteins using high throughput methods of multiplexed immunohistochemistry and multispectral imaging. Multiplexed immunohistochemistry is performed by sequential application of primary antibodies with secondary antibodies conjugated to horseradish peroxidase or alkaline phosphatase. Different chromogens are used to detect each protein of interest. Stained slides are loaded into an automated slide scanner and a protocol is created for automated image acquisition. A spectral library is created by staining a set of slides with a single chromogen on each. A subset of representative stained images are imported into multispectral imaging software and an algorithm for distinguishing tissue type is created by defining tissue compartments on images. Subcellular compartments are segmented by using hematoxylin counterstain and adjusting the intrinsic algorithm. Thresholding is applied to determine positivity and protein co-localization. The final algorithm is then applied to the entire set of tissues. Resulting data allows the user to evaluate protein expression based on tissue type (ex. epithelia vs. stroma) and subcellular compartment (nucleus vs. cytoplasm vs. plasma membrane). Co-localization analysis allows for investigation of double-positive, double-negative, and single-positive cell types. Combining multispectral imaging with multiplexed immunohistochemistry and automated image acquisition is an objective, high-throughput method for investigation of biomarkers within tissues.

Introduction

المناعية (IHC) هي تقنية المختبرات القياسية للكشف عن البروتين داخل الأنسجة، وانها لا تزال تستخدم على نطاق واسع IHC في كل من البحث والتشخيص المرضي. تقييم IHC تلطيخ غالبا ما يكون نصف الكمية، وإدخال التحيز المحتمل في تفسير النتائج. وقد وضعت العديد من المناهج شبه الكمية التي تتضمن كلا من شدة تلطيخ ومدى تلطيخ إلى التشخيص النهائي 1-4. وتشمل الأنظمة الأخرى كثافة يحرز والمكان التحت خلوية من أجل توطين التعبير 5 أفضل. وغالبا ما تستخدم إدماج متوسط ​​درجات من المشاهدين متعددة من أجل تقليل آثار المشاهد واحد التحيز 6. وعلى الرغم من هذه الجهود، الذاتية في التحليل لا يزال، وخاصة عند تقييم مدى تلطيخ 7. توحيد البروتوكول والتقليل الذاتية من مدخلات الإنسان هو الهدف الأسمى لخلق دقيقة، النتائج IHC استنساخه.

محتوى "> وهناك خيارات أخرى إلى جانب IHC لتحديد تعبير البروتين داخل الأنسجة. وفي إعداد البحوث، وقد جرت العادة على النظر المناعية كوسيلة لفحص البروتين توطين في حين ينظر إلى تقنيات أخرى مثل immunoblotting كما معيار الذهب للتحقيق في التعبير البروتين . تحديد الأنسجة أو الخلايا التعبير عن مقصورة محددة صعبة دون دمج تقنيات متقدمة مثل تجزئة الخلية أو القبض على الليزر تسليخ مجهري 9،10. استخدام الأجسام المضادة الفلورسنت على شرائح الأنسجة يقدم حلا وسطا معقولا، ولكن خلفية تألق ذاتي بسبب NADPH، lipofuscins، شبكي ألياف الكولاجين، والإيلاستين يمكن أن تجعل الكميات الدقيقة من الصعب 11.

الآلية منصات علم الأمراض الحسابية هي اتجاها واعدا لمزيد من الكميات الموضوعية للأمراض تلطيخ 12-15. الجمع بين التصوير متعدد الأطياف مع ميكروأرس الأنسجةيسهل تحليل الإنتاجية العالية من البروتين التعبير في أحجام عينة كبيرة. مع هذه التقنيات، وتحليل البروتين شارك في الترجمة، وعدم التجانس تلطيخ، والأنسجة وتوطين التحت خلوية ممكن مع تخفيض جوهري في كل من التحيزات الكامنة والوقت اللازم للتحليل، بينما كان عائدا البيانات في مستمرة بدلا من الشكل القاطع 16. ولذلك، كان الغرض من هذه الدراسة هو إثبات فائدة من ومنهجية لأداء المناعية المضاعفة مع التحليل، وذلك باستخدام برامج التصوير متعدد الأطياف.

كتب هذا البروتوكول اليدوي، وتلطيخ المناعى تعدد الإرسال من قسم الأنسجة شريحة واحدة مع أربعة أجسام مضادة وحيدة النسيلة الأمثل. كتجربة نموذجية، والمضاعفة النووي المضادة للأرنب ألفا مستقبلات هرمون الاستروجين (ERα) ومستقبلات الاندروجين (AR) مع anti-الماوس CD147 بغشاء وبغشاء لمكافحة فأر E-كادهيرين. يمكن substitut أي الأجسام المضادة في الاختيارإد عن الأجسام المضادة المدرجة هنا، ولكن كل مجموعة من الأجسام المضادة يتطلب تحسين منفصل. يجب أن تكون المعالجة المسبقة لجميع الأجسام المضادة متطابقة. يجب أن يكون الأمثل الأجسام المضادة AR وCD147 على حدة وبعد ذلك حفل كوكتيل. تم الكشف عن كل الأجسام المضادة باستخدام نظام البوليمر خالية من البيوتين واحدة من 4 المكوره فريدة من نوعها.

Protocol

ملاحظة: بروتوكول يصف هنا تلطيخ وتحليل ميكروأري الأنسجة (TMA)، التي سبق وصفها 12،17،18. تم الحصول على قسم TMA سميكة 4 ميكرون من كتلة البارافين باستخدام مشراح القياسية. ملاحظة: مكتبة الطيفية لل4 المكوره ومباين ينبغي إنشاء لالكميات الصورة. من أجل القيام بذل…

Representative Results

في الشكل 1، يتم تنفيذ التدريب على أنسجة البروستاتا إلى صور شريحة في الظهارية وانسجة أجزاء، جنبا إلى جنب مع مقصورة غير الأنسجة. باستخدام الظهارية غشاء علامة E-كادهيرين، تم إجراء تقسيم الخلية إلى فصل النواة، السيتوبلازم، وأجزاء الغشاء، كما ه…

Discussion

استخدام المناعية التقليدية لتقييم التعبير البروتين محدودة، وأساليب ذاتية شبه الكمية للتحليل 22،23. وقد تم إنشاء منصات مسبقا لتحليل الإنتاجية العالية التعبير العلامات البيولوجية والتعريب. تجزئة مفصلة لكل من الأنسجة ومقصورات التحت خلوية يسمح للمستخدمين لدراسة …

Disclosures

The authors have nothing to disclose.

Acknowledgements

الكتاب أشكر جامعة مبادرات البحوث بالحركة ولاية ويسكونسن في مختبر علم الأمراض، في جزء بدعم من وزارة UW علم الأمراض والطب المخبري ومنحة UWCCC P30 CA014520، لاستخدام التسهيلات والخدمات التي تقدمها.

Materials

Xylene Fisher Chemical X3F1GAL NFPA rating:Health – 2, Fire – 3 , Reactivity-0
Ethyl Alcohol-200 proof Fisher Scientific 4355223 NFPA rating:Health – 0, Fire – 3 , Reactivity-0
Tris Base Fisher Scientific BP152-500 NFPA rating:Health – 2, Fire – 0 , Reactivity-0
Tris Hydroxymethyl aminomethane HCl Fisher Scientific BP153-1 NFPA rating:Health – 2, Fire – 0 , Reactivity-0
Tween 20 Chem-Impex 1512 NFPA rating:Health – 0, Fire –1 , Reactivity-0
Phosphate-buffered saline Fisher Scientific BP2944-100 NFPA rating:Health – 1, Fire –0 , Reactivity-0
Peroxidazed Biocare Medical PX968 Avoid contact with skin and eyes. May cause skin irritation and eye damage.
Diva Decloaker  Biocare Medical DV2004 This product has been classified as non‐hazardous based on the physical  and/or  chemical nature and/or concentration of ingredients. 
Estrogen Receptor alpha Thermo Fisher Scientific-Labvision RM9101 Not classified as hazardous
Androgen Receptor SCBT sc-816 Not classified as hazardous
CD147 Biodesign P87535M Not classified as hazardous
E-cadherin Dako M3612 Not classified as hazardous
Renoir Red Andibody Diluent Biocare Medical PD904 It is specially designed to work with Tris-based antibodies
DeCloaking Chamber  Biocare Medical Model DC2002 Take normal precautions for using a pressure cooker
Barrier pen-Immuno Edge  Vector Labs H-4000
Denaturing Kit-Elution step Biocare Medical DNS001H Not classified as hazardous
Mach 2 Goat anti-Rabbit HRP Polymer Biocare Medical RHRP520 Not classified as hazardous
Mach 2 Goat anti-Rabbit AP Polymer Biocare Medical RALP525 Not classified as hazardous
Mach 2 Goat anti-Mouse HRP Polymer Biocare Medical M3M530 Not classified as hazardous
Betazoid DAB Chromogen Kit Biocare Medical BDB2004 1. DAB is known to be a suspected carcinogen.
2. Do not expose DAB components to strong light or direct sunlight.
3. Wear appropriate personal protective equipment and clothing.
4. DAB may cause sensitization of skin. Avoid contact with skin and eyes.
5. Observe all federal, state and local environmental regarding disposal
Warp Red Chromogen Kit Biocare Medical WR806 Corrosive. Acid that may cause skin irritation or eye damage. 
Vina Green Chromogen Kit Biocare Medical BRR807 Harmful if swallowed
Bajoran Purple Chromogen Kit Biocare Medical BJP807 Flammable liquid. Keep away from heat, flames and sparks. Harmful by ingestion or absorption. Avoid contact with skin or eyes, and avoid inhalation.
Cat Hematoxylin Biocare Medical CATHE Purple  solution  with  a  mild  acetic  acid  (vinegar)  scent.  May  be
 irritating  to  skin  or  eyes.  Avoid  contact  with  skin  and  eyes.  Avoid  ingestion.
XYL Mounting Media Richard Allen 8312-4 NFPA rating:Health – 2, Fire – 3 , Reactivity-0
1.5 Coverslips Fisher Brand 22266858 Sharp edges
Incubation (Humidity)Chamber obsolete obsolete Multiple vendors available
Convection Oven Stabil- Therm C-4008-Q
Background Punisher Blocking Reagent Biocare Medical BP974 This product is not classified as hazardous. 
inForm software PerkinElmer CLS135781 Primary multispectral imaging software used in manuscript
Nuance software PerkinElmer NUANCEEX Software used for making spectral libraries within manuscript
Vectra microscope and slide scanner PerkinElmer VECTRA Automated slide scanner and microscope for obtaining IM3 image cubes

References

  1. Valdman, A., et al. Expression of redox pathway enzymes in human prostatic tissue. Anal Quant Cytol Histol. 31 (6), 367-374 (2009).
  2. Rimm, D. L., Camp, R. L., Charette, L. A., Olsen, D. A., Provost, E. Amplification of tissue by construction of tissue microarrays. Exp Mol Pathol. 70 (3), 255-264 (2001).
  3. Jonmarker, S., et al. Expression of PDX-1 in prostate cancer, prostatic intraepithelial neoplasia and benign prostatic tissue. APMIS. 116 (6), 491-498 (2008).
  4. McCarty, K. S., Miller, L. S., Cox, E. B., Konrath, J., McCarty, K. S. Estrogen receptor analyses. Correlation of biochemical and immunohistochemical methods using monoclonal antireceptor antibodies. Arch Pathol Lab Med. 109 (8), 716-721 (1985).
  5. Volante, M., et al. Somatostatin receptor type 2A immunohistochemistry in neuroendocrine tumors: a proposal of scoring system correlated with somatostatin receptor scintigraphy. Mod Pathol. 20 (11), 1172-1182 (2007).
  6. Muris, J. J., et al. Immunohistochemical profiling of caspase signaling pathways predicts clinical response to chemotherapy in primary nodal diffuse large B-cell lymphomas. Blood. 105 (7), 2916-2923 (2005).
  7. Jaraj, S. J., et al. Intra- and interobserver reproducibility of interpretation of immunohistochemical stains of prostate cancer. Virchows Arch. 455 (4), 375-381 (2009).
  8. Nakane, P. K., Pierce, G. B. Enzyme-labeled antibodies: preparation and application for the localization of antigens. J Histochem Cytochem. 14 (12), 929-931 (1966).
  9. Peters, T. J. Investigation of tissue organelles by a combination of analytical subcellular fractionation and enzymic microanalysis: a new approach to pathology. J Clin Pathol. 34 (1), 1-12 (1981).
  10. Emmert-Buck, M. R., et al. Laser Capture Microdissection. Science. 274 (5289), 998-1001 (1996).
  11. Waters, J. C. Accuracy and precision in quantitative fluorescence microscopy. J Cell Biol. 185 (7), 1135-1148 (2009).
  12. Huang, W., Hennrick, K., Drew, S. A colorful future of quantitative pathology: validation of Vectra technology using chromogenic multiplexed immunohistochemistry and prostate tissue microarrays. Hum Pathol. 44 (1), 29-38 (2013).
  13. Rimm, D. L. C-Path: A Watson-Like Visit to the Pathology Lab. Science Translational Medicine. 3 (108), (2011).
  14. Fiore, C., et al. Utility of multispectral imaging in automated quantitative scoring of immunohistochemistry. J Clin Pathol. 65 (6), 496-502 (2012).
  15. Stack, E. C., Wang, C., Roman, K. A., Hoyt, C. C. Multiplexed immunohistochemistry, imaging, and quantitation: A review, with an assessment of Tyramide signal amplification, multispectral imaging and multiplex analysis. Methods. 70 (1), 46-58 (2014).
  16. Rizzardi, A. E., et al. Quantitative comparison of immunohistochemical staining measured by digital image analysis versus pathologist visual scoring. Diagn Pathol. 7, 42 (2012).
  17. Bauman, T. M., et al. Characterization of fibrillar collagens and extracellular matrix of glandular benign prostatic hyperplasia nodules. PLoS One. 9 (10), e109102 (2014).
  18. Bauman, T. M., et al. Beta-catenin is elevated in human benign prostatic hyperplasia specimens compared to histologically normal prostate tissue. Am J Clin Exp Urol. 2 (4), 313-322 (2014).
  19. Bauman, T. M., Ewald, J. A., Huang, W., Ricke, W. A. CD147 expression predicts biochemical recurrence after prostatectomy independent of histologic and pathologic features. BMC Cancer. 15 (1), 549 (2015).
  20. Bauman, T. M., et al. Finasteride treatment alters tissue specific androgen receptor expression in prostate tissues. Prostate. 74 (9), 923-932 (2014).
  21. Nicholson, T. M., Sehgal, P. D., Drew, S. A., Huang, W., Ricke, W. A. Sex steroid receptor expression and localization in benign prostatic hyperplasia varies with tissue compartment. Differentiation. 85 (4-5), 140-149 (2013).
  22. Taylor, C. R., Levenson, R. M. Quantification of immunohistochemistry–issues concerning methods, utility and semiquantitative assessment II. Histopathology. 49 (4), 411-424 (2006).
  23. Matos, L. L., Trufelli, D. C., de Matos, M. G., da Silva Pinhal, M. A. Immunohistochemistry as an important tool in biomarkers detection and clinical practice. Biomark Insights. 5, 9-20 (2010).
  24. Kononen, J., et al. Tissue microarrays for high-throughput molecular profiling of tumor specimens. Nat Med. 4 (7), 844-847 (1998).
  25. Ong, C. W., et al. Computer-assisted pathological immunohistochemistry scoring is more time-effective than conventional scoring, but provides no analytical advantage. Histopathology. 56 (4), 523-529 (2010).
check_url/53837?article_type=t

Play Video

Cite This Article
Bauman, T. M., Ricke, E. A., Drew, S. A., Huang, W., Ricke, W. A. Quantitation of Protein Expression and Co-localization Using Multiplexed Immuno-histochemical Staining and Multispectral Imaging. J. Vis. Exp. (110), e53837, doi:10.3791/53837 (2016).

View Video