Summary

급성 심근 경색의 돼지 모델의 주요 결과 평가

Published: October 14, 2016
doi:

Summary

신뢰할 수 있고 정확한 결과 평가는 임상 적 치료에 대한 임상 치료의 번역을위한 열쇠입니다. 현재의 논문은 돼지 급성 심근 경색 모델에서 심장 성능과 손상의 세 가지 임상 적으로 일차 결과 변수를 평가하는 방법에 대해 설명합니다.

Abstract

Mortality after acute myocardial infarction remains substantial and is associated with significant morbidity, like heart failure. Novel therapeutics are therefore required to confine cardiac damage, promote survival and reduce the disease burden of heart failure. Large animal experiments are an essential part in the translational process from experimental to clinical therapies. To optimize clinical translation, robust and representative outcome measures are mandatory. The present manuscript aims to address this need by describing the assessment of three clinically relevant outcome modalities in a pig acute myocardial infarction (AMI) model: infarct size in relation to area at risk (IS/AAR) staining, 3-dimensional transesophageal echocardiography (TEE) and admittance-based pressure-volume (PV) loops. Infarct size is the main determinant driving the transition from AMI to heart failure and can be quantified by IS/AAR staining. Echocardiography is a reliable and robust tool in the assessment of global and regional cardiac function in clinical cardiology. Here, a method for three-dimensional transesophageal echocardiography (3D-TEE) in pigs is provided. Extensive insight into cardiac performance can be obtained by admittance-based pressure-volume (PV) loops, including intrinsic parameters of myocardial function that are pre- and afterload independent. Combined with a clinically feasible experimental study protocol, these outcome measures provide researchers with essential information to determine whether novel therapeutic strategies could yield promising targets for future testing in clinical studies.

Introduction

서방 세계 1 명 2 % – 감소 구혈률 (HFrEF) 심장 장애는 약 1에 영향을 미치는 모든 심부전의 경우 약 50 %를 차지한다. 그것의 가장 일반적인 원인은 급성 심근 경색 (AMI)입니다. AMI 후 급성 사망률이 증가 된 인식과 개선 된 치료 방법으로 크게 감소함에 따라, 강조는 만성 후유증으로 이동했다; 가장 눈에 띄는 존재 HFrEF 2,3. 함께 의료 비용 4가 증가함에 따라, 심부전 성장 전염병 이전 5 바와 같이 AMI 후 부작용 리모델링 높은 병진 돼지 모델에서 연구 될 수있는 신규의 진단 및 치료에 대한 필요성을 강조한다.

불리한 개조 모두, 결정 (예를 들면, 경색 크기) 및 관능 평가 (예를 들어, 심장 초음파) 종종 REL의 필요성을 나타내는 새로운 치료제의 효능을 시험에 사용iable과 상대적으로 저렴한 방법. 현재 연구의 목적은 급성 심근 경색의 돼지 모델에서 효능 시험에 중요한 안정적인 결과 측정을 도입함으로써 이러한 요구를 충족하는 것이다. 이러한 위험 (AAR), 3 차원 경식도 심 초음파 (3D-TEE) 상세한 입장 기반 압력 – 볼륨 (PV) 루프 획득에 지역 관련 경색 크기 (IS)를 포함한다.

경색 크기는 AMI 6 후 이상 반응 리모델링과 생존의 주요 결정 요인이다. 가역적으로 부상 심근을 회수 및 경색 크기를 제한 할 수 있습니다 허혈성 심근의 재관류가, 재관류 자체가 산화 스트레스의 발생과 과도한 염증 반응을 통해 추가 피해를하지만 (허혈 – 재관류 손상 (IRI)) 7. 따라서, IRI는 유망한 치료 대상으로 확인되었습니다. 경색 크기를 감소시키는 신규 한 치료제의 능력과 관련하여 평가 경색 크기에 의해 정량화위험 지역 (AAR)에. 큰 AAR 더 큰 절대 경색 크기 리드로 AAR 정량은 동물 모델의 관상 해부학 개체 간 변동을 보정하기 위해 필수적이다. 경색 크기를 직접 심장 성능 및 심근 수축력에 관련되기 때문에, AAR의 변화는 치료 방법 (8)에 관계없이 결과 측정 연구에 영향을 미칠 수있다.

세 가지 차원 경식도 심 초음파 (3D-TEE)는 심장 기능이 비 침습적으로 측정 할 수있는 임상 적 적용, 가장 중요한, 안전하고 신뢰할 수있는 저렴한 방법입니다. 흉부 심장 초음파 (TTE) 이미지 돼지 9 2D 흉골 장기 및 단기 축보기에 한정되는 반면, 3D-TEE는 좌심실의 완전한 3 차원 이미지를 얻기 위해 사용될 수있다. 따라서, 이러한 수정 된 심슨의 규칙 10 좌심실 (LV) 볼륨의 수학 근사값을 필요로하지 않습니다. 후자는 CORR 하회ectly 인해 원통 형상 (11)의 부족 LV 개장 후 LV 볼륨을 추정. 그것은 본 모델 (12) 심장 보호 효과를 발휘하는 것으로 관찰되었다 외과 적 개입을 필요로하지 않기 때문에 또한, 3 차원 초음파 검사 TEE은 심 외막 위에 바람직하다. 심근 기능의 평가 2D-TEE의 사용 13,14 전에 설명 하였지만, 심실 기하 구조에 대한 제한은 2D-TTE에서 관찰 된 것과 유사하며 LV 리모델링의 정도에 의존한다. 따라서, 큰 경색 (및 심부전의 확률이 높은) 일수록 차원 측정이 부정확 기하학적 가정하여 결함되고 3D 기법이 높을 필요가있다.

그럼에도 불구하고, 대부분의 이미징 양식은 심근의 고유의 기능적 특성을 평가하는 능력에 제한됩니다. PV는 관련 추가 정보를 제공 루프 및 인수 그러므로상세히 설명.

Protocol

모든 동물 실험은 대학 의료 센터 위트 레흐트의 동물 실험에 대한 윤리위원회 (위트레흐트, 네덜란드)의 승인을하고 '실험 동물의 관리 및 사용에 대한 가이드'에 부합했다. 주 :이 프로토콜은 폐쇄 상자 풍선 흡장 현재 원고의 일부가 아닌 다른 곳에서 5 상세히 설명 수행. 즉, 돼지 (60-70kg)는 좌전 하행 동맥 (LAD)의 중앙부의 75 분 인 transluminal 풍선 폐색을 실시?…

Representative Results

3D 경식도 심 초음파 경식도 심장 초음파 3 차원 (3D-TEE)는 글로벌 심장 기능 평가에 사용될 수있다. AMI 후, 글로벌 심장 기능 건강 기준 값과 다릅니다. 특히, 좌심실 구혈률 (LVEF)는 재관류 일주 (N = 10) (GPJ 반 후트 2015 년) 후 37 ± 6 %, 59 ± 4 %에서 감소한다. 최종 이완기 볼륨이 두 시점 사이에 차이가없는 반면 박…

Discussion

심장 재 형성은 주로 심근 경색 크기에 의존하고, 심근 경색의 품질 6,26 수리. 표준화 된 방식으로 전자를 평가하기 위해, 본 원고 검증 광범위 8,16,27,28 사용생체 TTC 염색법과 조합 에반스 블루의 생체 내 주입 우아한 방법을 제공한다. 이 방법은 16 AAR 관련된 위험 (AAR)의 영역의 정량 경색 크기 허용한다. 이 심근 구멍을 요구하지 않는 한 유두근 – malposition…

Disclosures

The authors have nothing to disclose.

Acknowledgements

The authors gratefully acknowledge Marlijn Jansen, Joyce Visser, Grace Croft, Martijn van Nieuwburg, Danny Elbersen and Evelyn Velema for their excellent technical support during the animal experiments.

Materials

3-dimensional transesophageal echocardiography
iE33 ultrasound device Philips
X7-2t transducer Philips
Aquasonic® 100 ultrasound transmission gel Parker Laboratories Inc. 01-34 Alternative product can be used
Battery handle type C (laryngoscope handle) Riester 12303
Ri-Standard Miller blade MIL 4 (laryngoscope blade) Riester 12225
Qlab 10.0 (3DQ Advanced) analysis software Philips
Name Company Catalog Number Comments
Pressure-volume loop acquisition
Cardiac defibrillator Philips
0.9% saline Braun
8F Percutaneous Sheath Introducer Set Arrow CP-08803 Alternative product can be used
9F Radifocus® Introducer II Standard Kit  Terumo RS*A90K10SQ Alternative product can be used
8F Fogarty catheter Edward Life Sciences 62080814F Alternative product can be used
7F Criticath™ SP5107H TD catheter (Swan-Ganz) Becton Dickinson (BD) 680078 Alternative product can be used
Ultraview SL Patient Monitor and Invasive Command Module (external cardiac output device) Spacelabs Healthcare 91387 Alternative product can be used
ADVantage system™ Transonic SciSense
7F tetra-polar admittance catheter (7.0 VSL Pigtail / no lumen) Transonic SciSense
Multi-channel acquisition system (Iworx 404) Iworx
Labscribe V2.0 analysis software Iworx Alternative product can be used
Name Company Catalog Number Comments
Infarct size / area-at-risk quantification
Diathermy Alternative product can be used
Lebsch knife Alternative product can be used
Hammer Alternative product can be used
Bone marrow wax Syneture Alternative product can be used
Klinkenberg scissors Alternative product can be used
Retractor Alternative product can be used
Surgical scissors
7F Percutaneous Sheath Introducer Set  Arrow CP-08703 Alternative product can be used
8F Percutaneous Sheath Introducer Set  Arrow CP-08803 Alternative product can be used
7F JL4 guiding catheter  Boston Scientific H749 34357-662 Alternative product can be used
8F JL4 guiding catheter  Boston Scientific H749 34358-662  Alternative product can be used
COPILOT Bleedback Control Valves  Abbott Vascular 1003331 Alternative product can be used
BD Connecta™  Franklin Lakes 394995 Alternative product can be used
Contrast agent Telebrix
Persuader 9 Steerable Guidewire 9 (0.014", 180 cm, straight tip), hydrophilic coating Medtronic Inc. 9PSDR180HS Alternative product can be used
SAPPHIRE™ Coronary Dilatation Catheter (PTCA balloon suitable for the size of the particular coronary artery (2.75 – 3.25 mm)) OrbusNeich 103-3015 Alternative product can be used
Evans Blue  Sigma-Aldrich E2129-100G Toxic. Alternative product can be used
2,3,5-triphenyl-tetrazolium chloride (TTC) Sigma-Aldrich T8877-100G Irritant. Alternative product can be used
9V battery
Ruler
Photocamera Sony
ImageJ National Institutes of Health Alternative product can be used

References

  1. Mosterd, A., Hoes, A. W. Clinical epidemiology of heart failure. Heart. 93 (9), 1137-1146 (2007).
  2. Nichols, M., et al. . European Cardiovascular Disease Statistics. , (2012).
  3. Krumholz, H. M., et al. Reduction in Acute Myocardial Infarction Mortality in the United States. JAMA. 302 (7), 767-773 (2010).
  4. Go, A. S., et al. Heart disease and stroke statistics – 2013 update: A Report from the American Heart Association. Circulation. 127 (1), (2013).
  5. Koudstaal, S., et al. Myocardial infarction and functional outcome assessment in pigs. J. Vis. Exp. (86), e51269 (2014).
  6. Chareonthaitawee, P., Christian, T. F., Hirose, K., Gibbons, R. J., Rumberger, J. A. Relation of initial infarct size to extent of left ventricular remodeling in the year after acute myocardial infarction. J. Am. Coll. Cardiol. 25 (3), 567-573 (1995).
  7. Yellon, D. M., Hausenloy, D. J. Myocardial reperfusion injury. N. Engl. J. Med. 357 (11), 1221-1235 (2007).
  8. Suzuki, Y., Lyons, J. K., Yeung, A. C., Ikeno, F. In vivo porcine model of reperfused myocardial infarction: In situ double staining to measure precise infarct area/area at risk. Catheter Cardiovasc. Interv. 71 (1), 100-107 (2008).
  9. Weidemann, F., et al. Myocardial function defined by strain rate and strain during alterations in inotropic states and heart rate. Am. J. Physiol. Heart Circ. Physiol. 283 (2), H792-H799 (2002).
  10. Mercier, J. C., et al. Two-dimensional echocardiographic assessment of left ventricular volumes and ejection fraction in children. Circulation. 65 (5), 962-969 (1982).
  11. De Jong, R., et al. Cardiac Function in a Long-Term Follow-Up Study of Moderate and Severe Porcine Model of Chronic Myocardial Infarction. Biomed. Res. Int. 2015, 1-11 (2015).
  12. Van Hout, G. P. J., et al. Invasive surgery reduces infarct size and preserves cardiac function in a porcine model of myocardial infarction. J. Cell. Mol. Med. , 2655-2663 (2015).
  13. Meybohm, P., et al. Assessment of left ventricular systolic function during acute myocardial ischemia: A comparison of transpulmonary thermodilution and transesophageal echocardiography. Minerva Anestesiol. 77 (2), 132-141 (2011).
  14. Gruenewald, M., et al. Visual evaluation of left ventricular performance predicts volume responsiveness early after resuscitation from cardiac arrest. Resuscitation. 82 (12), 1553-1557 (2011).
  15. Bolli, R., Becker, L., Gross, G., Mentzer, R., Balshaw, D., Lathrop, D. A. Myocardial protection at a crossroads: The need for translation into clinical therapy. Circ. Res. 95 (2), 125-134 (2004).
  16. Timmers, L., et al. Exenatide reduces infarct size and improves cardiac function in a porcine model of ischemia and reperfusion injury. J. Am. Coll. Cardiol. 53 (6), 501-510 (2009).
  17. Csonka, C., et al. Measurement of myocardial infarct size in preclinical studies. J. Pharmacol. Toxicol. Methods. 61 (2), 163-170 (2010).
  18. Law, R., Katzka, D. A., Baron, T. H. Zenker’s Diverticulum. Clin. Gastroenterol. Hepatol. 12 (11), 1773-1782 (2014).
  19. Philips Healthcare. . QLAB 10.0 Quick Card: 3DQ and 3DQ Adv measurements guide. , (2013).
  20. Transonic. . ADV500 Pressure-Volume Measurement System Use and Care Manual, version 5. , (2006).
  21. Schramm, W. Is the cardiac output obtained from a Swan-Ganz catheter always zero?. J. Clin. Monit. Comput. 22 (6), 431-433 (2008).
  22. iWorx. . LabScribe 3: Software Manual for Pressure-Volume Analyses. , (2014).
  23. Hueper, W. C., Ichniowski, C. T. Toxicopathologic studies on the dye T-1824. Arch. Surg. 48 (1), 17-26 (1944).
  24. Van Hout, G. P. J., et al. Admittance-based pressure-volume loops versus gold standard cardiac magnetic resonance imaging in a porcine model of myocardial infarction. Physiol. Rep. 2 (4), 1-9 (2014).
  25. Burkhoff, D., Mirsky, I., Suga, H. Assessment of systolic and diastolic ventricular properties via pressure-volume analysis: a guide for clinical, translational, and basic researchers. Am. J. Physiol. Heart Circ. Physiol. Heart Circ. Physiol. 289 (2), H501-H512 (2005).
  26. Frangogiannis, N. G. The inflammatory response in myocardial injury, repair, and remodelling. Nat. Rev. Cardiol. 11 (5), 255-265 (2014).
  27. Fishbein, M., et al. Early phase acute myocardial infarct size quantification: validation of the triphenyl tetrazolium chloride tissue enzyme staining technique. Am. Heart. J. 101 (5), 593-600 (1981).
  28. Arslan, F., et al. Treatment with OPN-305, a humanized anti-toll-like receptor-2 antibody, reduces myocardial ischemia/reperfusion injury in pigs. Circ. Cardiovasc. Interv. 5 (2), 279-287 (2012).
  29. Meyns, B., Stolinski, J., Leunens, V., Verbeken, E., Flameng, W. Left ventricular support by Catheter-Mountedaxial flow pump reduces infarct size. J. Am. Coll. Cardiol. 41 (7), 1087-1095 (2003).
  30. Khalil, P. N., et al. Histochemical assessment of early myocardial infarction using 2,3,5-triphenyltetrazolium chloride in blood-perfused porcine hearts. J. Pharmacol. Toxicol. Methods. 54 (3), 307-312 (2006).
  31. Gardner, B. I., Bingham, S. E., Allen, M. R., Blatter, D. D., Anderson, J. L. Cardiac magnetic resonance versus transthoracic echocardiography for the assessment of cardiac volumes and regional function after myocardial infarction: an intrasubject comparison using simultaneous intrasubject recordings. Cardiovasc. Ultrasound. 7, 38 (2009).
  32. Santos-Gallego, C., et al. 3D-Echocardiography Demonstrates Excellent Correlation With Cardiac Magnetic Resonance for Assessment of Left Ventricular Function and Volumes in a Model of Myocardial Infarction. J. Am. Coll. Cardiol. 59 (13), E1564 (2012).
  33. Keith Jones, ., W, , et al. Peripheral nociception associated with surgical incision elicits remote nonischemic cardioprotection via neurogenic activation of protein kinase C signaling. Circulation. 120, S1-S9 (2009).
  34. Gross, G. J., Baker, J. E., Moore, J., Falck, J. R., Nithipatikom, K. Abdominal Surgical Incision Induces Remote Preconditioning of Trauma (RPCT) via Activation of Bradykinin Receptors (BK2R) and the Cytochrome P450 Epoxygenase Pathway in Canine Hearts. Cardiovasc. Drugs Ther. 25 (6), 517-522 (2011).
  35. Van Hout, G. P. J., de Jong, R., Vrijenhoek, J. E. P., Timmers, L., Duckers, H. J., Hoefer, I. E. Admittance-based pressure-volume loop measurements in a porcine model of chronic myocardial infarction. Exp. Physiol. 98 (11), 1565-1575 (2013).
  36. Sunagawa, K., Maughan, W. L., Burkhoff, D., Sagawa, K. Left ventricular interaction with arterial load studied in isolated canine ventricle. Am. J. Physiol. 245 (5 Pt 1), H773-H780 (1983).
  37. Steendijk, P., Baan, J., Der Velde, E. T. V. a. n., Baan, J. Effects of critical coronary stenosis on global systolic left ventricular function quantified by pressure-volume relations during dobutamine stress in the canine heart. J. Am. Coll. Cardiol. 32 (3), 816-826 (1998).
check_url/54021?article_type=t

Play Video

Cite This Article
Ellenbroek, G. H., van Hout, G. P., Timmers, L., Doevendans, P. A., Pasterkamp, G., Hoefer, I. E. Primary Outcome Assessment in a Pig Model of Acute Myocardial Infarction. J. Vis. Exp. (116), e54021, doi:10.3791/54021 (2016).

View Video