Journal
/
/
In vitro Multiparametrische Zellanalyse durch mikroorganisch ladungsmodulierte Feldeffekt-Transistorarrays
JoVE Journal
Bioengineering
This content is Free Access.
JoVE Journal Bioengineering
In Vitro Multiparametric Cellular Analysis by Micro Organic Charge-modulated Field-effect Transistor Arrays
DOI:

10:05 min

September 20, 2021

,

Chapters

  • 00:04Introduction
  • 01:12Substrate Selection, Preparation, and Floating Gates (FG): Titanium Deposition
  • 02:11FG Patterning and Gate Dielectric Deposition
  • 03:55Opening of the Sensing Areas of the OCMFET for Electrical Activity Recording and Formation of the Vias to Access the Back of the FGs
  • 04:46Self-Alignment of Source and Drain with the FG
  • 05:15Gold Deposition, Channel Formation, and Patterning of the Sources, Drains, and Control Gates
  • 06:50Deposition and Activation of the Parylene C for pH Sensing
  • 07:57Semiconductor Deposition, Culturing Chamber Placing, and Final Cut-Out of the Device from the PET
  • 08:22Results: Cellular Electrical and Metabolic Activity Recordings with Micro OCMFET Arrays (MOA)
  • 09:27Conclusion

Summary

Automatic Translation

Hier stellen wir das Herstellungsprotokoll eines OCMFET-basierten (Organic Charge-Modulated Field-Effect Transistor) Geräts für die in vitro zelluläre Schnittstelle vor. Das Gerät, das als Mikro-OCMFET-Array bezeichnet wird, ist ein flexibles, kostengünstiges und referenzloses Gerät, das die Überwachung der elektrischen und metabolischen Aktivitäten elektroaktiver Zellkulturen ermöglicht.

Related Videos

Read Article