Name |
Company |
Catalog Number |
Comments |
Heated Recirculator |
VWR Scientific |
13271-063 VWR |
For use with a heating jacket reactor system |
Variable Speed Electric Lab Stirrer |
Cleveland Mixer Co. |
(Model 5VB) |
This mixer model facilitates mounting with a ring stand |
Wet-Type Precision Gas Meter |
Ritter Gasmeters |
(Model TG-01) |
This model needs a minimum flow of (0.1 L/h) and can handle a maximum flow of 30 L/h |
Gas Bubbler |
Chemglass |
(Model AF-0513-20) |
|
Gas Sampling Tube |
Chemglass |
(Model CG-1808) |
|
Axial Impeller |
Lightnin’ |
R04560-25 Cole-Parmer |
Impeller blades with 7.9375 mm bore diameter |
Impeller Shaft |
Grainger |
2EXC9 Grainger |
1.83 m stainless steel rod with 7.9375 mm O.D. (needs to be cut to appropriate size) |
Cast Iron Support Stands |
American Educational Products |
(Model 7-G16) |
For mixer mounting |
Three-Prong Extension Clamp |
Talon |
21572-803 VWR |
For mixer mounting |
Regular Clamp Holder |
Talon |
21572-501 VWR |
For mixer mounting |
Peristaltic Pump |
Masterflex |
WU-07523-80 Cole-Parmer |
For effluent decanting |
L/S Standard Pump Head |
Masterflex |
EW-07018-21 Cole-Parmer |
For effluent decanting -accessory to peristaltic pump |
L/S Precision Pump Tubing |
Masterflex |
EW-06508-18 Cole-Parmer |
For effluent decanting - accessory to peristaltic pump |
pH Analysis |
pH Meter |
Thermo Fisher Scientific - Orion |
1212000 |
|
Total and Volatile Solids Analysis (Standard Methods: 2540-B,E) |
Glass Vacuum Dessicator |
Kimax |
WU-06536-30 Cole-Parmer |
|
Porcelain Evaporating Dishes |
VWR |
89038-082 VWR |
|
Lab Oven |
Thermo Fisher Scientific |
(Model 13-246-516GAQ) |
|
Medium Chamber Muffle Furnace |
Barnstead/ Thermolyne |
F6010 Thermo Scientific |
|
Total Volatile Fatty Acid Analysis (Standard Methods: 5560-C) |
Large Capacity Variable Speed Centrifuge |
Sigma |
WU-17451-00 Cole-Parmer |
|
Laboratory Hot Plate |
Thermo Scientific |
(Model HP53013A) |
|
Large Condenser |
Kemtech America |
(Model C150190) |
|
Acetic Acid Reagent [CAS: 64-19-7] |
Alfa Aesar |
AA33252-AK |
|
Chemical Oxygen Demand (Standard Methods: 5520-C) |
COD Block Heater |
HACH |
(Model DRB-200) |
|
Borosilicate Culture Tubes |
Pyrex |
(Model 9825-13) |
|
Potassium Dichromate Reagent [CAS: 7778-50-9] |
Avantor Performance Materials |
3090-01 |
|
Mercury II Sulfate Reagent [CAS: 7783-35-9] |
Avantor Performance Materials |
2640-04 |
|
Ferroin Indicator Solution [CAS: 14634-91-4] |
Ricca Chemical |
R3140000-120C |
|
Ammonium iron(II) sulfate hexahydrate [CAS: 7783-85-9] |
Alfa Aesar |
13448-36 |
|
Gas Composition by Gas Chromatography Analysis |
Gas Chromatograph |
SRI Instruments |
Model 8610C |
Must be equipped with a thermal conductibility detector (TCD), using below mentioned column and carrier gas operated at an isothermal temperature of 105 °C |
Helium Gas |
Airgas |
He HP300 |
To be used as the carrier gas |
Packed-Column |
Restek |
80484-800 |
To be used for N2, CH4, and CO2 separation |