Waiting
Traitement de la connexion…

Trial ends in Request Full Access Tell Your Colleague About Jove
Experiment
JoVE Encyclopedia of Experiments
Encyclopedia of Experiments: Immunology

Un abonnement à JoVE est nécessaire pour afficher ce contenu. Connectez-vous ou commencez votre essai gratuit.

An In Vivo PET Imaging Technique to Detect Tumors in a Murine Model Using Radiolabeled Antibodies

 

An In Vivo PET Imaging Technique to Detect Tumors in a Murine Model Using Radiolabeled Antibodies

Article

Transcript

In male athymic nude mice, subcutaneously implant 5 x 106 LNCaP prostate cancer cells, allowing these to grow to a 100 to 150 millimeter-cubed xenograft. Three to four weeks after inoculation, the tumors should be ready.

For imaging, dilute the 89Zr-DFO-J591 radio immunoconjugate to a concentration of 1 millicuries per milliliter in 0.9% sterile saline. Next, inject 200 microliters of the 89Zr-DFO-J591 solution into the lateral tail vein of the xenograft-bearing mice.

At the desired imaging time point, anesthetize the mouse with a 2% isoflurane:oxygen gas mixture. Place the mouse on a small animal PET scanner bed. Verify anesthesia using the toe-pinch method, and apply veterinary ointment to the eyes of the mouse to prevent drying during anesthesia.

Maintain anesthesia during the scan using a 1% isoflurane:oxygen gas mixture. Following this, acquire the PET data for the mouse via static scan with a minimum of 40 million coincident events using an energy window of 350 to 700 kiloelectron volts and a coincidence timing window of six nanoseconds.

Read Article

Get cutting-edge science videos from JoVE sent straight to your inbox every month.

Waiting X
Simple Hit Counter