Bioactive and mechanically reliable metal scaffolds have been fabricated through a method which consists of two processes, dynamic freeze casting for the fabrication of porous Ti, and coating and densification of the Ti scaffolds. The densification process is simple, effective and applicable to the fabrication of functionally graded scaffolds.

Abstract

Biometal systems have been widely used for biomedical applications, in particular, as load-bearing materials. However, major challenges are high stiffness and low bioactivity of metals. In this study, we have developed a new method towards fabricating a new type of bioactive and mechanically reliable porous metal scaffolds-densified porous Ti scaffolds. The method consists of two fabrication processes, 1) the fabrication of porous Ti scaffolds by dynamic freeze casting, and 2) coating and densification of the porous scaffolds. The dynamic freeze casting method to fabricate porous Ti scaffolds allowed the densification of porous scaffolds by minimizing the chemical contamination and structural defects. The densification process is distinctive for three reasons. First, the densification process is simple, because it requires a control of only one parameter (degree of densification). Second, it is effective, as it achieves mechanical enhancement and sustainable release of biomolecules from porous scaffolds. Third, it has broad applications, as it is also applicable to the fabrication of functionally graded porous scaffolds by spatially varied strain during densification.

Introduction

金属の生体材料が広く、それらの優れた機械的強度や弾力性、1-3の耐荷重インプラント、内部固定デバイスとして使用されてきたが、それらは2つの重要な課題が伴う:1)機械的な不一致を金属は生体組織よりもはるかに硬いので、望ましくない損害を引き起こします周囲組織としばしばしばしば異物反応例えば炎症または血栓症)を引き起こす、生物学的組織と悪い界面をもたらす。4-6多孔性金属足場は改善、構造において骨成長を促進するために提案されている2)低い生物活性に骨-インプラント接触応力遮蔽効果は、それらの低減剛性を抑制しつつ7-9また、種々の表面改質は、金属インプラントの生物学的活性を増強するために適用されています。このような改変は、生物活性分子( 例えば、成長 FACで金属表面を被覆含まター)または薬物 (例えば、バンコマイシン、テトラサイクリン)。10-12しかし、このような多孔性金属足場の減少、機械的特性等の問題が、剛性が低下し、生物活性コーティング層の迅速な放出は未解決のまま。13-16

具体的には、チタン(Ti)およびTi合金は、その優れた機械的特性、化学的安定性、および良好な生体適合性の中で最も人気のあるバイオメタルシステムの一つです。13,17-19彼らの泡状のアプリケーションが3Dので、関心の高まりをもを集めています多孔質のネットワークは、骨様の機械的特性に加えて、骨の内部成長を促進する。20-22努力は、ポリマースポンジの複製、金属粒子の焼結、ラピッドプロトタイピング(RP)方式を含む新しい製造技術を開発することにより、機械的特性を改善するためになされている、および毛穴の様々な機能を制御するために、スペースホルダー法例えば、細孔画分、形状、大きさ、分布、および接続)と材料特性( 例えば 、金属相と不純物)。23-25 ​​近年、水ベースの金属スラリーの凍結鋳造は、よく整列細孔と機械的に強化されたTi形態を製造するために、かなりの注目を集めています凝固時に一方向の氷のデンドライト成長を利用した構造。しかし、水と金属粉末の接触による酸素汚染は、Ti足場の脆化を最小限にするために、特別な注意が必要です。14,15

したがって、我々は、生物活性と機械的に同調可能な多孔性のTi足場を製造に向けた新たなアプローチを開発しました。25足場は最初に50%以上の気孔率を有する多孔質構造を有しています。製造された多孔質足場は、生物活性分子でコーティングされ、その後、最終的な多孔性、機械的特性および薬物放出挙動は、アプリによって制御された時に機械的なプレスを用いて圧縮しました。ED株。緻密化した多孔質チタンインプラントは、骨(3-20万気圧)。2ので、コーティング層のと同等の剛性が低いのにもかかわらず、良好な強度と低い多孔性を示してきた、緻密化多孔質チタンの生物活性が大幅に改善されました。また、ために高密度化プロセスにより誘導されたユニークなフラットな細孔構造の、コーティングされた生物活性分子は徐々に長期間その有効性を維持し、足場から放出されることが見られました。

本研究では、生物医学的用途における潜在的な使用のために緻密化した多孔質チタンの足場を製造するために、当社の確立された方法を紹介しました。プロトコルは、金属スラリーと多孔質足場の緻密化とダイナミック凍結鋳造が含まれています。まず、 図1(a)に示すように 、動的凍結鋳造法が導入された良好な延性を有する多孔質チタン足場を作製しました。 Ti粉末を液体カンフェン中に分散させました。次に、温度を下げることにより、液相は、Ti粉末ネ​​ットワークと固体カンフェン結晶間の相分離をもたらす、固化させました。その後、凝固したTi-カンフェングリーン体は、Ti粉末を連続チタン支柱と縮合され、カンフェン相が完全に多孔質構造を得るために除去された焼結しました。得られた多孔質足場を有するコーティング及び緻密化プロセスが緻密化し、初期空隙率の度合いを変化させること、を使用しました。コー​​ティング層およびその放出挙動は、GFPでコーティングされた高密度のチタンと比較して緻密化して多孔質とすることなく、チタンコーティングを採用して可視化し、緑色蛍光タンパク質(GFP)を用いて定量しました。最後に、二つの異なる多孔質構造を有する傾斜機能チタン足場が提案され、多孔質足場の内側及び外側部分の緻密化の度合いを変えることによって実証されました。

Protocol

多孔性金属足場の作製1。 4初期多孔度(40、50、60、及び70)を有する多孔質チタン足場のために、表1に記載したように材料の適切な量を秤量した後、市販のTi粉末、カンフェン、及びKD-4を混合したTi-カンフェンスラリーを準備します。 500 mlのポリエチレン(PE)ボトルにスラリーを注ぎ、30 rpmでボールミルオーブン中で30分間55℃でボトルを回転させます。 60ミリ?…

Representative Results

多孔質チタン足場を製造するために使用される製造プロセスは、 図1Aに示されています。 Ti粉末を12時間44℃で容器の連続的な回転によってカンフェン中に均一に分散保持され、液体カンフェンが完全に固化している間、比較的重いTi粉末のいずれかの堆積物を最小限にすることができます。その結果、均質のTi-カンフェングリーン体は、図1(b)に示すように 、動的…

Discussion

バイオメタルシステムは、広く、生物医学的用途に使用されているが、特に、荷重支持材料として、高い剛性と低い金属の生物活性は、主要な課題とみなされてきました。本研究では、新しい金属系、生体模倣機械的特性ならびに持続的な放出挙動を持つ生理活性表面を有する緻密化多孔性金属足場の製造方法を確立しました。当社の製造方法の主要な利点は、1を含む)に、我々はすでに開…

Divulgazioni

The authors have nothing to disclose.

Acknowledgements

This research was supported by the Technology Innovation Program (Contract grant No. 0037915, WPM Biomedical Materials-Implant Materials) and Industrial Strategic Technology Development Program (Contract grant No. 10045329, Development of customized implant with porous structure for bone replacement), funded by the Ministry of Trade, industry & Energy (MI, Korea), and BK21 PLUS SNU Materials Division for Educating Creative Global Leaders (Contract grant No. 21A20131912052).

Materials

Titanium powder Alfa Aesar #42624 -325 mesh, 99.5% (metals basis)
Camphene SigmaAldrich #456055 95%, C10H16
KD-4 Croda ­ Hypermer, polymeric dispersant
Phosphate Buffer Solution (PBS) Welgene ML 008-01 ­
Green Fluorescent Protein (GFP) Genoss Co. >98% purity, 1mg/ml
Ball mill oven SAMHENUG ENERGY SH-BDO150 ­
Freeze dryer Ilshin Lab. PVTFD50A ­
Cold isostatic pressing (CIP) machine SONGWON SYSTEMS CIP 42260 ­
Vaccum furnace JEONG MIN INDUSTRIAL JM-HP20 ­
electical chaege machine FANUC robocut 0iB External use
Press machine CG&S AJP-200 ­
Confocal laser scanning spectroscopy (CLSM) Olympus FluoView FV1000 External use

Riferimenti

  1. Long, M., Rack, H. Titanium alloys in total joint replacement-a materials science perspective. Biomaterials. 19 (18), 1621-1639 (1998).
  2. Niinomi, M. Recent metallic materials for biomedical applications. Metall. Mater. Trans. A. 33 (3), 477-486 (2002).
  3. Frosch, K. H., Stürmer, K. M. Metallic biomaterials in skeletal repair. Eur. J. Trauma. 32 (2), 149-159 (2006).
  4. Huiskes, R., Weinans, H., Van Rietbergen, B. The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials. Clin. Orthop. Relat. Res. 274, 124-134 (1992).
  5. Kanayama, M., et al. In vitro biomechanical investigation of the stability and stress-shielding effect of lumbar interbody fusion devices. J. Neurosurg. Spine. 93 (2), 259-265 (2000).
  6. Jung, H. -. D., Kim, H. -. E., Koh, Y. -. H. Production and evaluation of porous titanium scaffolds with 3-dimensional periodic macrochannels coated with microporous TiO2. 135, 897-902 (2012).
  7. Jones, A. C., et al. Assessment of bone ingrowth into porous biomaterials using MICRO-CT. Biomaterials. 28 (15), 2491-2504 (2007).
  8. Li, J. P., et al. Bone ingrowth in porous titanium implants produced by 3D fiber deposition. Biomaterials. 28 (18), 2810-2820 (2007).
  9. Ahn, M. -. K., Jo, I. -. H., Koh, Y. -. H., Kim, H. -. E. Production of highly porous titanium (Ti) scaffolds by vacuum-assisted foaming of titanium hydride (TiH2) suspension. Mater. Lett. 120 (1), 228-231 (2014).
  10. Baas, J., et al. The effect of pretreating morselized allograft bone with rhBMP-2 and/or pamidronate on the fixation of porous Ti and HA-coated implants. Biomaterials. 29 (19), 2915-2922 (2008).
  11. Peng, L., Bian, W. -. G., Liang, F. -. H., Xu, H. -. Z. Implanting hydroxyapatite-coated porous titanium with bone morphogenetic protein-2 and hyaluronic acid into distal femoral metaphysis of rabbits. Chin. J. Traumatol. (English Edition). 11 (3), 179-185 (2008).
  12. Reiner, T., Kababya, S., Gotman, I. Protein incorporation within Ti scaffold for bone ingrowth using Sol-gel SiO2 as a slow release carrier. J. Mater. Sci. – Mater. Med. 19, 583-589 (2008).
  13. Lee, J. H., Kim, H. E., Shin, K. H., Koh, Y. H. Improving the strength and biocompatibility of porous titanium scaffolds by creating elongated pores coated with a bioactive, nanoporous TiO2 layer. Mater. Lett. 64, 2526-2529 (2010).
  14. Li, J. C., Dunand, D. C. Mechanical properties of directionally freeze-cast titanium foams. Acta Mater. 59 (1), 146-158 (2011).
  15. Chino, Y., Dunand, D. C. Directionally freeze-cast titanium foam with aligned, elongated pores. Acta Mater. 56 (1), 105-113 (2008).
  16. Kim, S. W., et al. Fabrication of porous titanium scaffold with controlled porous structure and net-shape using magnesium as spacer. Mater. Sci. Eng. C. 33 (5), 2808-2815 (2013).
  17. Brentel, A. S., et al. Histomorphometric analysis of pure titanium implants with porous surface versus rough surface. J. Appl. Oral Sci. 14 (3), 213-218 (2006).
  18. Buser, D., et al. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J. Biomed. Mater. Res. 25 (7), 889-902 (1991).
  19. Cochran, D., Schenk, R., Lussi, A., Higginbottom, F., Buser, D. Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: a histometric study in the canine mandible. J. Biomed. Mater. Res. 40 (1), 1-11 (1998).
  20. Young, D. R., Robb, R. A., Rock, M. G., Chao, E. Y. Analysis of periprosthetic tissue formation around a porous titanium endoprosthesis using CT-based spatial reconstruction. J. Comput. Assist. Tomo. 18 (3), 461-468 (1994).
  21. Spoerke, E. D., et al. A bioactive titanium foam scaffold for bone repair. Acta Biomater. 1 (5), 523-533 (2005).
  22. Jung, H. D., et al. Highly aligned porous Ti scaffold coated with bone morphogenetic protein-loaded silica/chitosan hybrid for enhanced bone regeneration. J. Biomed. Mater. Res. Part B Appl. Biomater. 102 (5), 913-921 (2013).
  23. Ryan, G. E., Pandit, A. S., Apatsidis, D. P. Porous titanium scaffolds fabricated using a rapid prototyping and powder metallurgy technique. Biomaterials. 29 (27), 3625-3635 (2008).
  24. Vasconcellos, L. M. R., et al. Porous titanium scaffolds produced by powder metallurgy for biomedical applications. Mater. Res. 11 (3), 275-280 (2008).
  25. Jung, H. D., Yook, S. W., Kim, H. E., Koh, Y. H. Fabrication of titanium scaffolds with porosity and pore size gradients by sequential freeze casting. Mater. Lett. 63 (17), 1545-1547 (2009).
  26. Jung, H. -. D., Jang, T. -. S., Wang, L., Kim, H. -. E., Koh, Y. -. H., Song, J. Novel strategy for mechanically tunable and bioactive metal implants. Biomaterials. 37, 49-61 (2015).
  27. Tarng, Y. S., Ma, S. C., Chung, L. K. Determination of optimal cutting parameters in wire electrical discharge machining. Int. J. Mach. Tools Manufact. 35 (12), 1693-1701 (1995).
  28. Jung, H. -. D., et al. Dynamic Freeze Casting for the Production of Porous Titanium (Ti) Scaffolds. Mater. Sci. Eng. C. 33 (1), 59-63 (2013).
  29. Lee, J. -. H., Kim, H. -. E., Shin, K. -. H., Koh, Y. -. H. Improving the strength and biocompatibility of porous titanium scaffolds by creating elongated pores coated with a bioactive, nanoporous TiO2. Mater. Lett. 64 (22), 2526-2529 (2010).
  30. Jung, H. -. D., Yook, S. -. W., Kim, H. -. E., Koh, Y. -. H. Fabrication of titanium scaffolds with porosity and pore size gradients by sequential freeze casting. Mater. Lett. 63 (17), 1545-1547 (2009).
  31. Yook, S. -. W., et al. Reverse freeze casting: A new method for fabricating highly porous titanium scaffolds with aligned large pores. Acta Biomater. 8 (6), 2401-2410 (2012).
  32. Yook, S. W., Yoon, B. H., Kim, H. E., Koh, Y. H., Kim, Y. S. Porous titanium (Ti) scaffolds by freezing TiH2/camphene slurries. Mater. Lett. 62 (30), 4506-4508 (2008).
  33. Yook, S. W., Kim, H. E., Koh, Y. H. Fabrication of porous titanium scaffolds with high compressive strength using camphene-based freeze casting. Mater. Lett. 63 (17), 1502-1504 (2009).
check_url/it/53279?article_type=t

Play Video

Citazione di questo articolo
Jung, H., Lee, H., Kim, H., Koh, Y., Song, J. Fabrication of Mechanically Tunable and Bioactive Metal Scaffolds for Biomedical Applications. J. Vis. Exp. (106), e53279, doi:10.3791/53279 (2015).

View Video