Summary

Quantificazione assoluta di A?<sub> 1-42</sub> In CSF Utilizzando un riferimento alla procedura di misurazione di massa spettrometrica

Published: March 21, 2017
doi:

Summary

A reference measurement procedure for the absolute quantification of Aβ1-42 in human CSF based on solid-phase extraction and liquid chromatography tandem mass spectrometry is described.

Abstract

Alzheimer’s disease (AD) is the most common neurodegenerative disease among the elderly and accounts for 60-80% of all cases of dementia. Currently, the diagnosis of AD is based on cognitive tests and mental state exams, but the peptide amyloid-beta (Aβ) in cerebrospinal fluid (CSF) is increasingly used in clinical trials and settings. As for most protein and peptide biomarkers, quantification is performed using antibody-based techniques, such as enzyme-linked immunosorbent assay (ELISA). However, intra- and inter-laboratory variability in these assays hamper its use as a diagnostic marker in clinical routine.

An antibody-independent Reference Measurement Procedure (RMP) was developed based on solid-phase extraction (SPE) and liquid chromatography (LC)-tandem mass spectrometry (MS/MS), where stable, isotope-labeled Aβ peptides were used as internal standards, enabling absolute quantification. A high-resolution quadrupole-orbitrap hybrid instrument was used for the measurements. The method allows for the quantification of CSF Aβ1-42 between 150-4,000 pg/mL.

Introduction

La malattia di Alzheimer (AD) è la forma più comune di demenza e colpisce circa 35 milioni di persone in tutto il mondo 1. Le caratteristiche neuropatologici della malattia ampiamente creduto di essere al centro della patogenesi sono grovigli neurofibrillari intracellulari di hyperphosphorylated proteina tau 2 e placche extracellulari costituito da (Ap) peptidi 3 aggregati beta-amiloide. In linea con questo, la valutazione della patologia placca in vivo da biomarcatori è stato recentemente inserito nei criteri diagnostici di ricerca per AD 4. Per misurazioni CSF di Ap 1-42, vari test immunologici sono disponibili e sono utilizzati in molti laboratori clinici 5. La concentrazione di Ap 1-42 in CSF è inferiore di circa il 50% in pazienti con AD rispetto al cognitivo normale anziani, riflettendo la deposizione del peptide in placche nel brain 6, 7.

Questi biomarcatori sono principalmente analizzati utilizzando saggi immunologici (ad esempio, le tecniche a base di anticorpi), ma questi test possono essere influenzati da effetti di matrice 8. L'uso di saggi immunologici su piattaforme tecnologiche diverse e la mancanza di test di standardizzazione 9, 10 rende l'introduzione di concentrazioni di cut-off globali difficili 11, 12. Un RMP analiticamente convalidato avrebbe permesso la calibrazione uniforme delle piattaforme di analisi diverse, idealmente con conseguente migliore comparabilità tra le piattaforme di analisi e in un migliore controllo dei fattori che contribuiscono alla variabilità complessiva di misura.

La quantificazione assoluta di Ap 1-42 con il metodo LC-MS / MS sviluppata supera molti dei problemi connessi con tecn a base di anticorpiiques. Il metodo, indicato come un RMP dal comitato misto per la tracciabilità in Medicina di Laboratorio (JCTLM archivio di identificazione numero C11RMP9), sarà utilizzato per determinare la concentrazione assoluta di Ap 1-42 in un materiale di riferimento certificato (CRM) per armonizzare CSF Ap 1 misurazioni -42 attraverso tecniche e piattaforme analitiche. Il flusso di lavoro descritto deve essere rilevante per lo sviluppo di metodi di riferimento candidato per peptidi e proteine ​​all'interno di altre aree della medicina.

Protocol

NOTA: Questo protocollo richiede aliquote di almeno 50 ml, con una concentrazione di 50 mg / ml per ciascun peptide Ap, come materiale di partenza. I peptidi Ap vanno dissolte in 20% acetonitrile (ACN) e il 4% di soluzione di ammoniaca concentrata in acqua deionizzata (v / v) e conservati a 80 ° C. Attenzione: Vedi Tabella 1 per le informazioni di sicurezza. 1. preparazione delle soluzioni Preparare 100 ml di 20% ACN e 4% ammoniaca co…

Representative Results

Il setup piatto in Figura 1 è utilizzato per un piatto pieno di campioni. Se un minor numero di campioni sconosciuti sono da analizzare, il secondo calibratore, set RF, e QC deve essere posto dopo la prima metà dei campioni sconosciuti. Come si vede nella figura 2, i calibratori sono vicini alla linea di regressione, con basse deviazioni standard. Questo metodo ha un livello inferiore di qua…

Discussion

Per il metodo descritto, invece di utilizzare una matrice surrogata, abbiamo usato il metodo surrogata analita 13, 14, 15, 16, che consente la calibrazione in CSF umano. L'approccio analita surrogato coinvolge due diversi standard marcati con isotopi. Uno (15 NAβ 142) è utilizzato per generare la curva di calibrazione in CSF umano, mentre un altro (13 CA?…

Disclosures

The authors have nothing to disclose.

Acknowledgements

This work was performed on behalf of the International Federation of Clinical Chemistry Working Group on CSF Proteins, which has the following composition: Kaj Blennow (Chair) and Henrik Zetterberg, Gothenburg University, Sweden; Les Shaw and Magdalena Korecka, University of Philadelphia, PA, USA; Ingrid Zegers, Institute for Reference Materials and Measurements, Geel, Belgium; Piotr Lewczuk, Universitätsklinikum Erlangen, Germany; and Rand Jenkins, PPD Bioanalytical Laboratory, Richmond, VA, USA; Randall Bateman, Washington University, MO, USA; and H Vanderstichele, Innogenetics NV, Ghent, Belgium. This work was also part of the Global Consortium for Biomarker Standardization CSF Reference Methods Working Group, which is led by Maria C. Carrillo, Ph.D., Senior Director, Medical & Scientific Relations, Alzheimer’s Association. The study was supported by The Swedish Research Council (grants #14002, #521-2011-4709, and #2013-2546); the Knut and Alice Wallenberg Foundation; Demensförbundet; and Emil and Wera Cornell’s, Aina Wallström and Mary-Ann Sjöblom’s, Gun and Bertil Stohne’s, Magnus Bergvall’s, and Gamla Tjänarinnor’s Foundations.

Materials

Eppendorf Protein LoBind microcentrifuge tubes, 0.5 mL Eppendorf 022431081
Eppendorf Protein LoBind microcentrifuge tubes, 1.5 mL Eppendorf 022431081
Eppendorf Protein LoBind microcentrifuge tubes, 2 mL Eppendorf 022431102
Eppendorf Protein LoBind microcentrifuge tubes, 5 mL Eppendorf 0030 108.310
Eppendorf Protein LoBind Deepwell Plates 96 Eppendorf 951032905
Micronic 0.75 mL polypropylene tubes, V-bottom Micronic MPW32071BC3 Tubes used for collecting SPE eluate, but other collection devices can be used such as 96-well plates.
Micronic Split TPE Capcluster for 96 ind. tubes Micronic MP53026 Caps for Micronic tubes.
Micronic Loborack-96 white w high cover bar coded Micronic MPW51015BC3 Holder for Micronic tubes.
Biohit Optifit tips 1.2 mL Sartorius 791210 Used to reach all the way to the bottom of the LoBind deepwell plates (96-well). Other narrow tips might work as well.
Waters Oasis MCX 96-well µElution Plate Waters 186001830BA 
Waters Plate manifold reservoir tray Waters WAT058942
Waters Extraction Plate Manifold for Oasis 96-Well Plates Waters 186001831
Ammonium hydroxide solution, puriss. p.a., reag. ISO, reag. Ph. Eur., ~25% NH3 basis Sigma-Aldrich 30501-1L-D
Acetonitrile, Far UV HPLC Gradient grade, 2.5 L Fisher Scientific A/0627/17X
ortho-Phosphoric acid 85%, ACS,ISO,Reag. Ph Eur Merck Millipore 1005731000
Guanidine Hydrochloride, 500 g Thermo Scientific 24110
Thermo Scientific Q-exactive Hybrid Quadrupole Orbitrap Mass Spectrometer Thermo Scientific IQLAAEGAAPFALGMAZR With bundled Dionex Ultimate 3000 LC & autosampler.
Dionex ProSwift RP-4H Monolith Column (1.0 x 250mm) Dionex 066640
Bovine Serum Albumin, lyophilized powder, suitable for (for molecular biology), Non-acetylated Sigma-Aldrich B6917
Beta-Amyloid (1-42), Ultra Pure, TFA rPeptide A-1002-2
15N Beta-Amyloid (1-42), Uniformly labeled rPeptide A-1102-2
13C Beta-Amyloid (1-42), Uniformly labeled rPeptide A-1106-2
Microplate shakers, TiMix 2 Edmund Bühler 6110 000

References

  1. Querfurth, H. W., LaFerla, F. M. Alzheimer’s disease. N Engl J Med. 362 (4), 329-344 (2010).
  2. Braak, H., Braak, E. Evolution of the neuropathology of Alzheimer’s disease. Acta Neurol Scand Suppl. 165, 3-12 (1996).
  3. Blennow, K., de Leon, M. J., Zetterberg, H. Alzheimer’s disease. Lancet. 368 (9533), 387-403 (2006).
  4. Dubois, B., et al. Advancing research diagnostic criteria for Alzheimer’s disease: the IWG-2 criteria. Lancet Neurol. 13 (6), 614-629 (2014).
  5. Blennow, K., Hampel, H., Weiner, M., Zetterberg, H. Cerebrospinal fluid and plasma biomarkers in Alzheimer disease. Nat Rev Neurol. 6 (3), 131-144 (2010).
  6. Buchhave, P., et al. Cerebrospinal fluid levels of beta-amyloid 1-42, but not of tau, are fully changed already 5 to 10 years before the onset of Alzheimer dementia. Arch Gen Psychiatry. 69 (1), 98-106 (2012).
  7. Olsson, B., et al. CSF and blood biomarkers for the diagnosis of Alzheimer’s disease: a systematic review and meta-analysis. The Lancet Neurology. 15 (7), 673-684 (2016).
  8. Bjerke, M., et al. Confounding factors influencing amyloid Beta concentration in cerebrospinal fluid. Int J Alzheimers Dis. , (2010).
  9. Dumurgier, J., et al. Intersite variability of CSF Alzheimer’s disease biomarkers in clinical setting. Alzheimers Dement. 9 (4), 406-413 (2013).
  10. Mattsson, N., et al. CSF biomarker variability in the Alzheimer’s Association quality control program. Alzheimers Dement. 9 (3), 251-261 (2013).
  11. Kang, J. H., Korecka, M., Toledo, J. B., Trojanowski, J. Q., Shaw, L. M. Clinical Utility and Analytical Challenges in Measurement of Cerebrospinal Fluid Amyloid-beta1-42 and tau Proteins as Alzheimer Disease Biomarkers. Clin Chem. 59 (6), 903-916 (2013).
  12. Mattsson, N., et al. Reference measurement procedures for Alzheimer’s disease cerebrospinal fluid biomarkers: definitions and approaches with focus on amyloid beta42. Biomark Med. 6 (4), 409-417 (2012).
  13. Ahmadkhaniha, R., Shafiee, A., Rastkari, N., Kobarfard, F. Accurate quantification of endogenous androgenic steroids in cattle’s meat by gas chromatography mass spectrometry using a surrogate analyte approach. Anal Chim Acta. 631 (1), 80-86 (2009).
  14. Jemal, M., Schuster, A., Whigan, D. B. Liquid chromatography/tandem mass spectrometry methods for quantitation of mevalonic acid in human plasma and urine: method validation, demonstration of using a surrogate analyte, and demonstration of unacceptable matrix effect in spite of use of a stable isotope analog internal standard. Rapid Commun Mass Spectrom. 17 (15), 1723-1734 (2003).
  15. Leinenbach, A., et al. Mass spectrometry-based candidate reference measurement procedure for quantification of amyloid-beta in cerebrospinal fluid. Clin Chem. 60 (7), 987-994 (2014).
  16. Li, W., Cohen, L. H. Quantitation of endogenous analytes in biofluid without a true blank matrix. Anal Chem. 75 (21), 5854-5859 (2003).
  17. Perret-Liaudet, A., et al. Cerebrospinal fluid collection tubes: a critical issue for Alzheimer disease diagnosis. Clin Chem. 58 (4), 787-789 (2012).
  18. Lewczuk, P., et al. Effect of sample collection tubes on cerebrospinal fluid concentrations of tau proteins and amyloid beta peptides. Clin Chem. 52 (2), 332-334 (2006).
  19. Pannee, J., et al. Reference measurement procedure for CSF amyloid beta (Aβ)1-42 and the CSF Aβ1-42 /Aβ1-40 ratio – a cross-validation study against amyloid PET. J Neurochem. 139 (4), 651-658 (2016).
  20. Thienpont, L. M., Van Houcke, S. K. Traceability to a common standard for protein measurements by immunoassay for in-vitro diagnostic purposes. Clin Chim Acta. 411 (23-24), 2058-2061 (2010).
  21. Vesper, H. W., Thienpont, L. M. Traceability in laboratory medicine. Clin Chem. 55 (6), 1067-1075 (2009).

Play Video

Cite This Article
Pannee, J., Blennow, K., Zetterberg, H., Portelius, E. Absolute Quantification of Aβ1-42 in CSF Using a Mass Spectrometric Reference Measurement Procedure. J. Vis. Exp. (121), e55386, doi:10.3791/55386 (2017).

View Video