Summary

Développement d'un<em> In vitro</em> Plateforme Ocular pour tester Lentilles de contact

Published: April 06, 2016
doi:

Summary

Les modèles actuels in vitro pour l' évaluation des lentilles de contact (Cls) et d' autres applications liés aux yeux sont très limitées. La plate-forme oculaire présenté simule l'écoulement physiologique de la déchirure, le volume larme, exposition à l'air et à l'usure mécanique. Ce système est très polyvalent et peut être appliquée à diverses analyses in vitro avec NFT.

Abstract

Currently, in vitro evaluations of contact lenses (CLs) for drug delivery are typically performed in large volume vials,1-6 which fail to mimic physiological tear volumes.7 The traditional model also lacks the natural tear flow component and the blinking reflex, both of which are defining factors of the ocular environment. The development of a novel model is described in this study, which consists of a unique 2-piece design, eyeball and eyelid piece, capable of mimicking physiological tear volume. The models are created from 3-D printed molds (Polytetrafluoroethylene or Teflon molds), which can be used to generate eye models from various polymers, such as polydimethylsiloxane (PDMS) and agar. Further modifications to the eye pieces, such as the integration of an explanted human or animal cornea or human corneal construct, will permit for more complex in vitro ocular studies. A commercial microfluidic syringe pump is integrated with the platform to emulate physiological tear secretion. Air exposure and mechanical wear are achieved using two mechanical actuators, of which one moves the eyelid piece laterally, and the other moves the eyeballeyepiece circularly. The model has been used to evaluate CLs for drug delivery and deposition of tear components on CLs.

Introduction

Deux domaines importants d'intérêt dans le domaine des lentilles de contact (CL) comprennent l'inconfort et le développement de nouvelles applications de CL. Élucider les mécanismes sous – jacents CL inconfort est une question qui a échappé le domaine depuis des décennies. 8 Le développement de nouveaux CLs fonctionnels, tels que les dispositifs d' administration de médicaments 1,3,9 et biocapteurs, 10-12 est un domaine d'intérêt croissant, avec des marchés potentiels importants. Dans les deux cas, un système sophistiqué dans le modèle in vitro pourrait fournir des informations pertinentes pour aider à la sélection appropriée des matériaux de lentilles ou des caractéristiques de conception lors de la phase de développement. Malheureusement, le courant des modèles in vitro pour évaluer CLs et d' autres applications oculaires liées sont relativement brut et sophistiqué. Traditionnellement, les études in vitro CL évaluant le dépôt du film lacrymal ou la délivrance de médicaments sont effectuées dans des flacons statiques, les grands volumes de fluide contenant un volume fixe, qui greadépasse tly quantités physiologiques. En outre, ce modèle simple n'a pas la composante de flux lacrymal naturel et le réflexe de clignement, qui sont tous deux des facteurs de l'environnement oculaire déterminant.

Le développement d'un «modèle» sophistiqué, physiologiquement pertinente de l' œil , il faudra une approche multidisciplinaire et exigent substantielle validation in vivo. Pour ces raisons, le cadre fondamental pour notre modèle in vitro de l' œil est très polyvalent, de sorte que le modèle peut être continuellement amélioré grâce à des améliorations et des modulations futures. À ce jour, le modèle est capable de simuler le volume larme, flux lacrymal, l'usure mécanique et exposition à l'air. L'objectif est de créer un modèle in vitro qui fournira des résultats significatifs, qui est prédictive et complémentaire à in vivo et ex vivo observations.

Protocol

Toutes les expériences ont été réalisées en conformité et le respect de toutes les directives pertinentes énoncées par l'Université de Waterloo le comité d'éthique de la recherche animale. Les yeux de l'espèce bovine sont généreusement offerts à partir d'un abattoir local. 1. Eye Model Conception et production de moules 13 Concevoir les modèles de l' oeil en fonction des dimensions physiologiques moyennes des yeux humains adultes. 13 <…

Representative Results

Les moules oculaires synthétisés obtenus à partir du magasin de machine et de l' impression 3D sont représentés sur la figure 1. Ces moules peuvent être utilisés avec une variété de polymères tels que le PDMS et d' agarose, pour produire des oculaires avec les propriétés souhaitées. L'assemblage fit signe de la plate – forme du modèle d'oeil avec une pompe à seringue microfluidique est représentée sur la figure 2. La plat…

Discussion

Il y a trois étapes critiques dans le protocole qui nécessitent une attention particulière: la conception et la production de moules (section 1.1), l'ensemble de la plate-forme (section 2.2.1-2.2.3), et le suivi de l'essai expérimental (section 2.2.4-2.2.7 ). En termes de conception et de production de moules (section 1.1), la pièce de globe oculaire doit être conçu selon les dimensions d'une cornée humaine. Cependant, il peut nécessiter plusieurs prototypes du moule avant une pièce de globe oculai…

Declarações

The authors have nothing to disclose.

Acknowledgements

Les auteurs tiennent à remercier notre source de financement du CRSNG 20/20 Réseau pour le développement d'Advanced Materials ophtalmiques.

Materials

Arduino Uno R3 (Atmega328 – assembled) Adafruit 50 Board
Stepper motor Adafruit 324 Motor and Motor shield
Equal Leg Coupler 1.6mm 1/16" VWR CA11009-280 50 pcs of tube connector
Tubing PT/SIL 1/16"x1/8" VWR 16211-316 Case of 50feet
PDMS Dow Corning Sylgard 184 Solar Cell Encapsulation
Agarose, Type 1-A, low EEO Sigma-Aldrich A0169-25G
PHD UltraTM Harvard Apparatus 703006 MicroFluidic Pump
Bovine cornea Cargill, Guelph/ON
Soldidworks Dassault Systemes Software
3-D printing University of Waterloo – 3D Print Centre
Dissection tools Fine Science Tools General dissection tools
Medium 199 Sigma-Aldrich Culture medium storage for cornea
Fetal bovine serum Thermo Fisher Add to culture medium, 3% total volume

Referências

  1. Phan, C. M., Subbaraman, L. N., Jones, L. In vitro drug release of natamycin from beta-cyclodextrin and 2-hydroxypropyl-beta-cyclodextrin-functionalized contact lens materials. J Biomater Sci Polym Ed. 25, 1907-1919 (2014).
  2. Peng, C. C., Kim, J., Chauhan, A. Extended delivery of hydrophilic drugs from silicone-hydrogel contact lenses containing vitamin E diffusion barriers. Biomaterials. 31, 4032-4047 (2010).
  3. Hui, A., Willcox, M., Jones, L. In vitro and in vivo evaluation of novel ciprofloxacin-releasing silicone hydrogel contact lenses. Invest Ophthalmol Vis Sci. 55, 4896-4904 (2014).
  4. Boone, A., Hui, A., Jones, L. Uptake and release of dexamethasone phosphate from silicone hydrogel and group I, II, and IV hydrogel contact lenses. Eye Contact Lens. 35, 260-267 (2009).
  5. Lorentz, H., Heynen, M., Trieu, D., Hagedorn, S. J., Jones, L. The impact of tear film components on in vitro lipid uptake. Optom Vis Sci. 89, 856-867 (2012).
  6. Hall, B., Phan, C. M., Subbaraman, L., Jones, L. W., Forrest, J. Extraction versus in situ techniques for measuring surface-adsorbed lysozyme. Optom Vis Sci. 91, 1062-1070 (2014).
  7. Mishima, S., Gasset, A., Klyce, S. D., Baum, J. L. Determination of tear volume and tear flow. Invest Ophthalmol Vis Sci. 5, 264-276 (1966).
  8. Nichols, J. J., et al. The TFOS international workshop on contact lens discomfort: executive summary. Invest Ophthalmol Vis Sci. 54, 7-13 (2013).
  9. Peng, C. C., Burke, M. T., Carbia, B. E., Plummer, C., Chauhan, A. Extended drug delivery by contact lenses for glaucoma therapy. J Control Release. 162, 152-158 (2012).
  10. Faschinger, C., Mossbock, G. Continuous 24 h monitoring of changes in intraocular pressure with the wireless contact lens sensor Triggerfish. First results in patients. Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft. 107, 918-922 (2010).
  11. Shaw, A. J., Davis, B. A., Collins, M. J., Carney, L. G. A technique to measure eyelid pressure using piezoresistive sensors. IEEE transactions on bio-medical engineering. 56, 2512-2517 (2009).
  12. Liao, Y. T., Yao, H. F., Lingley, A., Parviz, B., Otis, B. P. A 3-mu W CMOS glucose sensor for wireless contact-lens tear glucose monitoring. Ieee J Solid-St Circ. 47, 335-344 (2012).
  13. Coster, D. J. . Cornea. , (2002).
  14. Parekh, M., et al. A simplified technique for in situ excision of cornea and evisceration of retinal tissue from human ocular globe. Journal of visualized experiments : JoVE. , e3765 (2012).
  15. Way, S. Gear and pinion. US patent. , (1942).
  16. Lorentz, H., et al. Contact lens physical properties and lipid deposition in a novel characterized artificial tear solution. Molecular vision. 17, 3392-3405 (2011).
  17. Furukawa, R. E., Polse, K. A. Changes in tear flow accompanying aging. American journal of optometry and physiological optics. 55, 69-74 (1978).
  18. Bajgrowicz, M., Phan, C. M., Subbaraman, L., Jones, L. Release of ciprofloxacin and moxifloxacin from daily disposable contact lenses from an in vitro eye model. Invest Ophthalmol Vis Sci. , (2015).
  19. Luensmann, D., Zhang, F., Subbaraman, L., Sheardown, H., Jones, L. Localization of lysozyme sorption to conventional and silicone hydrogel contact lenses using confocal microscopy. Current eye research. 34, 683-697 (2009).
  20. Tieppo, A., Pate, K. M., Byrne, M. E. In vitro controlled release of an anti-inflammatory from daily disposable therapeutic contact lenses under physiological ocular tear flow. Eur J Pharm Biopharm. 81, 170-177 (2012).
  21. Ali, M., et al. Zero-order therapeutic release from imprinted hydrogel contact lenses within in vitro physiological ocular tear flow. J Control Release. 124, 154-162 (2007).
  22. White, C. J., McBride, M. K., Pate, K. M., Tieppo, A., Byrne, M. E. Extended release of high molecular weight hydroxypropyl methylcellulose from molecularly imprinted, extended wear silicone hydrogel contact lenses. Biomaterials. 32, 5698-5705 (2011).
  23. Kaczmarek, J. C., Tieppo, A., White, C. J., Byrne, M. E. Adjusting biomaterial composition to achieve controlled multiple-day release of dexamethasone from an extended-wear silicone hydrogel contact lens. J Biomater Sci Polym Ed. 25, 88-100 (2014).
  24. Mohammadi, S., Postnikoff, C., Wright, A. M., Gorbet, M. Design and development of an in vitro tear replenishment system. Ann Biomed Eng. 42, 1923-1931 (2014).
  25. Lorentz, H., Heynen, M., Khan, W., Trieu, D., Jones, L. The impact of intermittent air exposure on lipid deposition. Optom Vis Sci. 89, 1574-1581 (2012).
  26. Peng, C. C., Fajardo, N. P., Razunguzwa, T., Radke, C. J. In vitro spoilation of silicone-hydrogel soft contact lenses in a model-blink cell. Optom Vis Sci. 92, 768-780 (2015).
  27. Liu, P., et al. Dissolution studies of poorly soluble drug nanosuspensions in non-sink conditions. AAPS PharmSciTech. 14, 748-756 (2013).

Play Video

Citar este artigo
Phan, C., Walther, H., Gao, H., Rossy, J., Subbaraman, L. N., Jones, L. Development of an In Vitro Ocular Platform to Test Contact Lenses. J. Vis. Exp. (110), e53907, doi:10.3791/53907 (2016).

View Video