Summary

뚜껑 와이퍼 지역의 인상 세포학

Published: August 09, 2016
doi:

Summary

We collected, stained and imaged cells from the conjunctiva of the inner eyelid margin of human subjects. By characterizing cell morphology and metabolic activity, this method may further our understanding of dry eye and the role that friction between the ocular surfaces may play in perceiving ocular discomfort.

Abstract

Few reports on the cellular anatomy of the lid wiper (LW) area of the inner eyelid exist and only one report makes use of cytological methods. The optimization of a method of collecting, staining and imaging cells from the LW region using impression cytology (IC) is described in this study. Cells are collected from the inner surface of the upper eyelid of human subjects using hydrophilic polytetrafluoroethylene (PTFE) membranes, and stained with cytological dyes to reveal the presence of goblet cells, mucins, cell nuclei and various degrees of pre- and para-keratinization. Immunocytochemical dyes show cell esterase activity and compromised cell membranes by the use of a confocal scanning laser microscope. Up to 100 microscopic digital images are captured for each sample and stitched into a high-resolution, large scale image of the entire IC span. We demonstrate a higher sensitivity of IC than reported before, appropriate for identifying cellular morphologies and metabolic activity in the LW area. To our knowledge, this is the first time this selection of fluorescent dyes was used to image LW IC membranes. This protocol will be effective in future studies to reveal undocumented details of the LW area, such as assessing cellular particularities of contact lens wearers or patients with dry eye or lid wiper epitheliopathy.

Introduction

2mm 좁은 결막 지역 안구 세계를 반대 – 인간의 위 눈꺼풀 단지 1로, 1 만 깜박 매일 1 주위를 실행합니다. 깜짝 동안의 와이 핑 동작으로 인해, 뚜껑 마진이 부분은 ​​"뚜껑 와이퍼"영역 (2)로 명명되었다. 이는 마찰에 의한 지구 위로 닦아 뚜껑에 습관적 깜박임 동안이 영역에서 증가하는 것으로한다. 이는 안구 시설에 중요한 역할을 할 수있다. 콘택트 렌즈는 특별한 경험 안구 불편에 착용자이 렌즈는 3 착용 중단의 주요 원인 중 하나입니다. 콘택트 렌즈는 눈에 위치 될 때 렌즈 재료 및 안구 표면 사이의 마찰 계수 4를 변경하는 것으로 나타났다. 건조 현상이 변경된 마찰 2,5,6- 관련 될 수 있음을 시사하는 증거가있다.

이 협회는 또한 임상 적으로 관찰 가능한 현상에 반영 될 수 있으며, 특히 뚜껑 위스콘신epitheliopathy (LWE)라고도 상부 덮개 마진 염색 (ULMS) 6 당. LWE은 안구 자극의 초기 기호 및 안구 건조 질환을 유발할 수있는 위험이 예측이다. 이 관찰 상하 뚜껑 마진 영역 생체 염색에 의해 측정된다. 이 등급 시스템 (2) 및 임상 적 유효성 (즉, 자각 증상과 상관 관계가) 논쟁에서 여전히 있지만, 안구 불편 함이 모두 의사와 과학자에 대한 수수께끼를 유지하고, 가장 중요한, 환자의 불편.

– 날짜, 작은 뚜껑 와이퍼 영역 (7)의 (서브) 세포 해부학과 생리학에 임상 적으로 관련 변화에 대해 알려진 단 하나의 보고서는 세포 학적 방법 (8)을 사용한다. 노출 세포진 검사 (IC)는 막 9,10의 응용 프로그램에 의해 안구 또는 눈꺼풀 결막의 상피 표면에서 세포를 수집하기 위해 40 년 이상 사용되어왔다. 제거시, 부착 세포는 C를 거쳐ytological 염색 및 현미경 영상. 때문에 뚜껑 와이퍼 영역의 해부학 적 및 세포의 차이로,이 기술은 최적화를 필요로한다.

Protocol

윤리 문 : 이전 인체에서 세포를 수집에 대한 동의를 통보 윤리 승인을 취득해야합니다. 1. 얼룩 준비 주 : 실험의 날에 얼룩을 준비합니다. 15 ㎖의 원심 분리기 튜브에 2.5 ml의 인산염 완충 생리 식염수 (PBS) 5 ㎕를 에티 디움 (4 μM) 5 ㎕를 칼 세인 AM (4 μM)를 추가; 혼합. 사용할 때까지 RT에서 빛과 가게에서 보호하는 알루미늄 호일에 싸서. <…

Representative Results

플라스틱 홀더 위에 스팬 세포 배양 막은 덮개 와이퍼 결막 상피 세포에서의 핸드 헬드 컬렉션 편리한 도구이다. 이 방법은 일반적으로 제조 및 IC 막을 처리하는 데 추가적인 멸균 장비에 대한 필요성을 제거한다. (1) 세포 배양 삽입물을 이용하여 뚜껑 와이퍼 영역의 IC를 보여주고있다. 우리는 새로운 방식으로 뚜껑 와이퍼 영역에서 상피 세포의…

Discussion

노출은 통상적 세포학 혼합 셀룰로오스 에스테르 막을 사용하여, 구 결막에 대해 수행된다. 샘플, 대량 재료의 시트에서 크기로 잘라 멸균 집게를 사용하여 결막 표면에서 적용되고 제거됩니다. 동일한 막 재료를 사용하여 피스톤 제어 IC 디바이스의 최근 어플리케이션 (13) 사이 일관된 압력을 구 결막의 표면 형상과 일치하고, 유지하도록 설계되었다. 이러한 접근은 지역 와이퍼 좁은, 눈…

Offenlegungen

The authors have nothing to disclose.

Acknowledgements

We would like to acknowledge our colleague Dr. Jalaiah Varikooty who provided insight and expertise on the topic of the lid wiper, that greatly assisted this research.

Materials

Alcian Blue, 1% in 3% Acetic Acid Sigma B8438-250ML
Hematoxylin, Gill 1 Sigma GHS116-500ML
Papanicolaou stain, OG-6 Sigma HT40116-500 ml
Papanicolaou stain, Modified EA Sigma HT40232-1L
Live/Dead Viability/Cytotoxicity Kit Life Technologies L-3224 contains ethidium homodimer-1 and Calcein AM dyes
Alcaine (0.5% proparacaine hydrochloride) Alcon
Millicell Cell Culture Insert, 12 mm, hydrophilic PTFE, 0.4 µm EMD Millipore PICM01250 
35 mm Glass Bottom Dishes MatTek Corporation P35G-0-20-C

Referenzen

  1. Barbato, G., et al. Diurnal variation in spontaneous eye-blink rate. Psychiatry Res. 93, 145-151 (2000).
  2. Korb, D. R., et al. Lid-Wiper Epitheliopathy and Dry-Eye Symptoms in Contact Lens Wearers. Eye & Contact Lens. 28, 211-216 (2002).
  3. Dumbleton, K., Woods, C. A., Jones, L. W., Fonn, D. The impact of contemporary contact lenses on contact lens discontinuation. Eye & Contact Lens. 39, 93-99 (2013).
  4. Roba, M., Duncan, E., Hill, G., Spencer, N., Tosatti, S. Friction measurements on contact lenses in their operating environment. Tribol Lett. 44, 387-397 (2011).
  5. Sickenberger, W., Pult, H., Sickenberger, B. LIPCOF and contact lens wearers: a new tool to forecast subjective dryness and degree of comfort of contact lens wearers. Contactologia. 22, 74-79 (2000).
  6. Pult, H., Purslow, C., Berry, M., Murphy, P. J. Clinical tests for successful contact lens wear: relationship and predictive potential. Optom Vis Sci. 85, E924-E929 (2008).
  7. Doughty, M. J. Morphological features of cells along Marx’s line of the marginal conjunctiva of the human eyelid. Clin Exp Optom. 96, 76-84 (2013).
  8. Jalbert, I., et al. Assessing the human lid margin epithelium using impression cytology. Acta Ophthalm. 90, e547-e552 (2012).
  9. Nelson, J. D. Impression cytology. Cornea. 7, 71-81 (1988).
  10. Egbert, P. R., Lauber, S., Maurice, D. M. A simple conjunctival biopsy. Am J Ophthalmol. 84, 798-801 (1977).
  11. Wilson, T. . Confocal microscopy. , 1-64 (1990).
  12. Denk, W., Strickler, J. H., Webb, W. W. Two-photon laser scanning fluorescence microscopy. Science. 248, 73-76 (1990).
  13. Tomlins, P., Roy, P., Curnow, J., Rauz, S. Assessment of the EyePRIM Device for Conjunctival Impression for Flow Cytometry. Invest Ophthalm Vis Sci. 54, 5430-5430 (2013).
  14. Knop, E., Korb, D. R., Blackie, C. A., Knop, N. The lid margin is an underestimated structure for preservation of ocular surface health and development of dry eye disease. Res Proj Dry Eye Syn. 45, 108-122 (2010).
  15. Knop, E., et al. The lid wiper and muco-cutaneous junction anatomy of the human eyelid margins: an in vivo confocal and histological study. J Anat. 218, 449-461 (2011).
  16. Christensen, J. A., Skaarland, E. Nuclear and cell area measurements in the cytological evaluation of pleural effusions: a study of subjective assessments and morphometric measurements. Diag Cytopathol. 3, 50-54 (1987).
check_url/de/54261?article_type=t

Play Video

Diesen Artikel zitieren
Muntz, A., van Doorn, K., Subbaraman, L. N., Jones, L. W. Impression Cytology of the Lid Wiper Area. J. Vis. Exp. (114), e54261, doi:10.3791/54261 (2016).

View Video