Summary

Transporters in cell membranes allow differential segregation of ions across cell membranes or cell layers and play crucial roles during tissue physiology, repair and pathology. We describe the ion-selective self-referencing microelectrode that allows the measurement of specific ion fluxes at single cells and tissues in vivo.

Abstract

Le cellule ottenute da animali, piante e cellule singole sono racchiusi da una barriera chiamato la membrana cellulare che separa il citoplasma dall'esterno. Strati cellulari come epiteli formano anche una barriera che separa l'interno dall'esterno o diversi compartimenti di organismi multicellulari. Una caratteristica fondamentale di queste barriere è la distribuzione differenziale di ioni attraverso le membrane cellulari o strati di cellule. Due proprietà consentono questa distribuzione: 1) membrane e epiteli mostrano permeabilità selettiva di ioni specifici; 2) gli ioni sono trasportati attraverso le pompe attraverso le membrane cellulari e strati di cellule. Queste proprietà giocano un ruolo cruciale nel mantenimento della fisiologia dei tessuti e fungono da segnalazione spunti dopo i danni, durante la riparazione, o in condizioni patologiche. L'auto-riferimento microelettrodo ionoselettivo consente misurazioni di flussi specifici di ioni come calcio, potassio o sodio a livelli cellulari e tissutali singoli. Il microelettrodo contiene un cocktail ionoforo che èselettivamente permeabile ad uno ione specifico. La soluzione di riempimento interna contiene una concentrazione insieme di ione di interesse. Il potenziale elettrico del microelettrodo è determinata dalla concentrazione fuori dello ione. Poiché la concentrazione di ioni varia, il potenziale del microelettrodo cambia in funzione del log della attività ionica. Quando spostato avanti e indietro vicino a una fonte o affondare dello ione (cioè in un gradiente di concentrazione dovuto al flusso di ioni) il potenziale microelettrodo oscilla ad una ampiezza proporzionale al flusso di ioni / gradiente. L'amplificatore amplifica il segnale microelettrodo e la produzione è registrata sul computer. Il flusso di ioni può essere calcolata dalla legge di Fick della diffusione usando le fluttuazioni potenziale dell'elettrodo, l'escursione di microelettrodo, e altri parametri quali la mobilità ionica specifico. In questo articolo, si descrive nel dettaglio la metodologia per misurare flussi ionici extracellulari con il autoreferenziale microelettrodi uno ione-selettivod presentare alcuni risultati rappresentativi.

Introduction

Tutte le cellule animali sono circondate da una membrana a doppio strato lipidico che separa il citoplasma dall'ambiente esterno. La cella mantiene un potenziale di membrana elettrico, negativa all'interno, dal trasporto attivo di ioni 1. Il potenziale di membrana è una fonte di energia accumulata che la cellula può utilizzare per operare vari dispositivi molecolari nella membrana 2. I neuroni e le altre cellule eccitabili hanno grandi potenziali di membrana. Rapid apertura dei canali del sodio crolla il potenziale di membrana (depolarizzazione) e produce il potenziale di azione che viene trasportato lungo la lunghezza del neurone 2. Oltre a questi cambiamenti rapidi elettrici, molti tessuti e organi generare e mantenere significativi potenziali elettrici a lungo termine. Ad esempio, la pelle e dell'epitelio corneale generare e mantenere potenziali trans-epiteliali e correnti elettriche extracellulari pompando direzionale di ioni (soprattutto sodio e cloruro) 3.

tenda "> Mentre misure di corrente elettrica endogena extracellulare utilizzando la sonda vibrante 4-6 e le misurazioni dei potenziali di membrana o trans-epiteliali utilizzando il sistema microelettrodo 7-10 consentire la misurazione dei parametri elettrici di membrane cellulari e strati di cellule epiteliali, non danno indicazione della specie ionici coinvolti.

Microelettrodi con ionophore selettivo in grado di misurare la concentrazione di ioni in soluzione specifica. Gradienti ionici o flusso possono essere misurati con due o più elettrodi in posizioni diverse. Tuttavia, la deriva della tensione intrinseca di ciascuna sonda sarebbe diversa, causando misurazioni imprecise o anche il rilevamento di un gradiente che non era presente. Un singolo elettrodo utilizzato in modalità "auto-riferimento" in cui si muove a bassa frequenza tra due punti risolve questo problema. Ora il flusso di ioni può essere visto sullo sfondo di una deriva del segnale relativamente lento e stabile (vedere Figura 3B). </p>

Il sistema di misurazione sensibile agli ioni utilizza microelettrodi autoreferenziali ionoselettivi di rilevare piccoli flussi extracellulari di ioni nei pressi di tessuti o cellule singole. Il sistema è costituito da un amplificatore che elabora il segnale dal microelettrodo e un motore passo-passo micro e guidatore a controllare il movimento del microelettrodo. Il microelettrodo ione-selettivo e l'elettrodo di riferimento che chiude il circuito sono collegati all'amplificatore tramite un headstage preamplificatore (Figura 1A). Software determina i parametri del movimento microelettrodo (frequenza, distanza) e registra anche l'uscita dell'amplificatore. Il motore passo-passo controlla il movimento tramite un microelettrodo micropositioner tridimensionale. Una bassa frequenza di oscillazione microelettrodi ione-selettivo è stato sviluppato nel 1990 per misurare il flusso di calcio specifica 11. Così come il calcio, cocktail ionofori accessibili in commercio sono ora disponibili a fare microelectrodes sensibile al sodio, cloruro, potassio, idrogeno, magnesio, nitrato, ammonio, fluoruro, litio o mercurio.

Fondamentalmente, la tecnica microelettrodo ionoselettivo autoreferenziale converte l'attività di uno ione specifico disciolto in una soluzione in un potenziale elettrico, che può essere misurata con un voltmetro. Il cocktail ionoforo è un liquido immiscibile fase (organica, lipofila) con proprietà a scambio ionico. L'ionoforo complessi selettivamente (binding) ioni specifici reversibilmente e li trasferisce tra la soluzione acquosa contenuta nel microelettrodo (elettrolita) e la soluzione acquosa in cui è immerso il microelettrodo (Figura 1D). Questo trasferimento di ioni porta un equilibrio elettrochimico e una variazione di potenziale elettrico tra il microelettrodo e l'elettrodo di riferimento è misurata dal voltmetro. La tensione è proporzionale al logaritmo dell'attività ione specifico secondo l'Nernst equation consentendo il calcolo della concentrazione di ioni (Figura 2A e B).

Attualmente, alcuni sistemi permettono la misurazione del flusso ionico usando un concetto o principio simile. Ad esempio, l'elettrodo tecnica di scansione ionoselettivo (SIET) 12,13 o il (MIFE) tecnica microelettrodo Ion Flux Stima sviluppata da Newman e Shabala 14-16 sono disponibili in commercio e ampiamente utilizzati dalla comunità di ricerca al fine di determinare ione specifico fondenti si verificano a membrana e tessuti cellulari attraverso una varietà di animali, piante e modelli a cella singola vita. Microelettrodi ionoselettivi sono stati utilizzati per misurare l'idrogeno, il potassio e il flusso di calcio attraverso le radici delle piante 17, flux cloruro nel ratto arterie cerebrali 18 e in tubetti pollinici 19, flusso di idrogeno in cellule retiniche pattino 20, flusso di calcio nelle ossa del mouse 21, ione vari flussi di ife fungine e 22 in ra 23 della cornea, e, infine, il flusso di calcio durante ferita singola cellula di guarigione 12,24. Si veda anche la seguente recensione per informazioni dettagliate sul ionoselettive autoreferenziali microelettrodi 25.

Il seguente articolo descrive in dettaglio come preparare ed eseguire la misurazione di flussi ionici endogeni extracellulari utilizzando l'autoreferenziale tecnica microelettrodi ionico selettivo a livello di singola cellula.

Protocol

1. Ion-selettivi autoreferenziale microelettrodo Preparazione Preparazione di microelettrodo ione-selettivi Tirare calore sottili capillari borosilicato a parete senza filamento (diametro esterno 1,5 mm 1,12 millimetri di diametro interno) con un estrattore microelettrodo. Nota: questo dà consigli 3-4 micron di diametro. Punte piccole hanno resistenza superiore che rende microelettrodi più sensibili al rumore elettronico ed è anche associato ad una risposta più lenta ad una variazione dell…

Representative Results

Abbiamo precedentemente dimostrato che l'influsso di calcio compare dopo singola cellula ferendone 24. Abbiamo quindi chiesto se gli altri flussi ionici si verificano su di ferimento singola cellula. Abbiamo usato la X. laevis ovocita, un modello consolidato per singola cella la guarigione delle ferite 30-34 e registrazione elettrofisiologica 24,35-39. È interessante notare, gli ioni potassio sono più concentrati all'interno X. laevis ovociti (circa 110 mm) <s…

Discussion

Le fasi più critiche per la misurazione successo flussi ionici extracellulari in vivo sono: la riduzione del rumore, la corretta realizzazione dell'elettrodo microelettrodi ionoselettivi e riferimento, e il posizionamento del campione e due elettrodi.

Per minimizzare il rumore, il sistema di registrazione dovrebbe essere collegato a terra (massa) gabbia di Faraday preferibilmente con un (isolamento dalle vibrazioni) Tavolo metallo con ripiano che è anche collegata a terra. Ino…

Disclosures

The authors have nothing to disclose.

Acknowledgements

This work was supported by National Science Foundation grant MCB-0951199, and in part by the NIH grant EY01910, California Institute of Regenerative Medicine grants RB1-01417 and by the Fundação para a Ciência e Tecnologia (FCT) grant SFRH/BD/87256/2012.

Materials

IonAmp   BioCurrents Research Center, Woods Hole, MA, USA none amplifier created by the BioCurrents Research Center, Woods Hole, MA, USA; Similar system can be purchased from “XBL function matters” (http://www.xuyue.org/) or from “YoungerUSA” (http://www.youngerusa.com/) or from Applicable Electronics(http://www.applicableelectronics.com/)
IonAmp32   BioCurrents Research Center, Woods Hole, MA, USA none software created by the BioCurrents Research Center, Woods Hole, MA, USA; Similar system can be purchased from “XBL function matters” (http://www.xuyue.org/) or from “YoungerUSA” (http://www.youngerusa.com/) or from Applicable Electronics(http://www.applicableelectronics.com/)
Headstage pre-amplifier  BioCurrents Research Center, Woods Hole, MA, USA INA116 BSR Voltage Follower INA116, designed by the BioCurrents Research Center, Woods Hole, MA, USA; Similar system can be purchased from “XBL function matters” (http://www.xuyue.org/) or from “YoungerUSA” (http://www.youngerusa.com/) or from Applicable Electronics(http://www.applicableelectronics.com/)
MicroStep Driver  BioCurrents Research Center, Woods Hole, MA, USA none three MicroStep drivers are required for X, Y and Z-positioning; created by the BioCurrents Research Center, Woods Hole, MA, USA; Similar system can be purchased from “XBL function matters” (http://www.xuyue.org/) or from “YoungerUSA” (http://www.youngerusa.com/) or from Applicable Electronics(http://www.applicableelectronics.com/)
Manual micropositioner   World Precision Instruments  Model KITE-R Similar system can be purchased from Applicable Electronics(http://www.applicableelectronics.com/)
Magnetic stand    World Precision Instruments Model M10 Similar system can be purchased from Applicable Electronics(http://www.applicableelectronics.com/)
Vibration isolation table   Newport Inc.      Model VW-3036-OPT-023040 Similar system can be purchased from Applicable Electronics(http://www.applicableelectronics.com/)
Part of three dimentional micropositioner: angle bracket, 90°, slotted faces Newport Inc.      Model 360-90 Assemblage of the three dimantionnal micropositionner requires also Three electric rotary motors for X, Y, Z control, MPH-1 mounting arm with MCA-2 adjustable-angle post and Various Newport connectors and screws to bolt onto vibration table
Part of three dimentional micropositioner: Peg-Joining Dovetail Stage 0.5 inch X Travel Newport Inc.      460PD-X none
Part of three dimentional micropositioner: Quick-Mount Linear Stage, 0.5 inch XY Travel Newport Inc. 460A-XY none
Kwik-Fil thin walled borosilicate glass capillaries without filament  World Precision Instruments  TW150-4 none
Electrode puller  Narishige  PC-10 none
Metal rack Made in-house none Metal electrode holder made in-house by drilling 2 mm wide holes half centimeter spaced in a 10cm by 15cm rectangular base of steel
Oven QL Model 10 Lab Oven none
Silanization solution I  Sigma-Aldrich 85126 Hazardous, handle as recommended by provider 
Glass Petri dish; Pyrex Fisher Scientific 316060 none
Electrode/micropipette storage jar World Precision Instruments  E215 none
Glass dessicator Fisher Scientific 08-595E Contains Drierite dessicant (W.A. Hammond Drierite Co. Ltd, Xenia, OH, USA). Place petroleum jelly on the seal to make it airtight.
Plastic Pasteur pipette  Fisher Scientific 11597722 none
Bunsen burner Fisher Scientific S97329 none
Microscope slide Sigma-Aldrich S8902 none
Straight microelectrode holder Warner Instruments QSW-A15P with a gold 1 mm male connector and Ag/AgCl wire
Straight microelectrode holder  World Precision Instruments MEH3S with a AgCl(Ag+)pellet inside and a gold 2 mm male connector 
6 cm Petri dish VWR 60872-306 none
Nitex mesh Dynamic Aqua-Supply Ltd. NTX750 none
Glue; Loctite epoxy VWR 500043-451 Mix glue and hardener in equal parts in a plastic weighing boat and mix thoroughly. Sets quickly but leave at RT for 24 h for full curing
Deionized water  Sigma-Aldrich 99053 none
Sodium Chloride Sigma-Aldrich S7653 none
Potassium Chloride Sigma-Aldrich P9333 none
Calcium Chloride Sigma-Aldrich C1016 none
Magnesium Chloride Sigma-Aldrich M8266 none
Hepes Sigma-Aldrich H3375 none
Sodium Hydroxyde Sigma-Aldrich S8045 none
Potassium Acetate Sigma-Aldrich P1190 none
Agarose Sigma-Aldrich A9539 none

References

  1. Weber, W. M., Liebold, K. M., Clauss, W. Amiloride-sensitive Na+ conductance in native Xenopus oocytes. Biochimica et biophysica acta. 1239, 201-206 (1995).
  2. McCaig, C. D., Song, B., Rajnicek, A. M. Electrical dimensions in cell science. Journal of cell science. 122, 4267-4276 (2009).
  3. Zhao, M. Electrical fields in wound healing-An overriding signal that directs cell migration. Seminars in cell & developmental biology. 20, 674-682 (2009).
  4. Jaffe, L. F., Nuccitelli, R. An ultrasensitive vibrating probe for measuring steady extracellular currents. The Journal of cell biology. 63, 614-628 (1974).
  5. Reid, B., Nuccitelli, R., Zhao, M. Non-invasive measurement of bioelectric currents with a vibrating probe. Nature protocols. 2, 661-669 (2007).
  6. Reid, B., Zhao, M. Measurement of bioelectric current with a vibrating probe. Journal of visualized experiments : JoVE. , (2011).
  7. Neher, E., Sakmann, B. Single-channel currents recorded from membrane of denervated frog muscle fibres. Nature. 260, 799-802 (1976).
  8. Moore, J. W. The patch clamp: single-channel recording. Science. 224, 50-51 (1984).
  9. Brown, A. L., Johnson, B. E., Goodman, M. B. Patch clamp recording of ion channels expressed in Xenopus oocytes. Journal of visualized experiments. , (2008).
  10. McCaig, C. D., Robinson, K. R. The ontogeny of the transepidermal potential difference in frog embryos. Developmental biology. 90, 335-339 (1982).
  11. Kuhtreiber, W. M., Jaffe, L. F. Detection of extracellular calcium gradients with a calcium-specific vibrating electrode. The Journal of cell biology. 110, 1565-1573 (1990).
  12. Cai, G., Cresti, M., Moscatelli, A. The use of the vibrating probe technique to study steady extracellular currents during pollen germination and tube growth. Fertilisation in Higher Plants: molecular and cytological aspects. , 235-252 (1999).
  13. Kunkel, J. G., Xu, Y., Shipley, A. M., Feijó, J. A. The use of non-invasive ion-selective microelectrode techniques for the study of plant development. Plant Electrophysiology – Theory and Methods. (ed Volkov AG. , 109-137 (2006).
  14. Ordonez, N. M., Shabala, L., Gehring, C., Shabala, S. Noninvasive microelectrode ion flux estimation technique (MIFE) for the study of the regulation of root membrane transport by cyclic nucleotides. Methods in molecular biology. 1016, 95-106 (2013).
  15. Tegg, R. S., Melian, L., Wilson, C. R., Shabala, S. Plant cell growth and ion flux responses to the streptomycete phytotoxin thaxtomin A: calcium and hydrogen flux patterns revealed by the non-invasive MIFE technique. Plant & cell physiology. 46, 638-648 (2005).
  16. Newman, I. A. Ion transport in roots: measurement of fluxes using ion-selective microelectrodes to characterize transporter function. Plant, cell & environment. 24, 1-14 (2001).
  17. Kochian, L. V., Shaff, J. E., Kuhtreiber, W. M., Jaffe, L. F., Lucas, W. J. Use of an extracellular, ion-selective, vibrating microelectrode system for the quantification of K(+), H (+), and Ca (2+) fluxes in maize roots and maize suspension cells. Planta. 188, 601-610 (1992).
  18. Doughty, J. M., Langton, P. D. Measurement of chloride flux associated with the myogenic response in rat cerebral arteries. The Journal of physiology. 534, 753-761 (2001).
  19. Messerli, M. A., Smith, P. J., Lewis, R. C., Robinson, K. R. Chloride fluxes in lily pollen tubes: a critical reevaluation. The Plant journal : for cell and molecular biology. 40, 799-812 (2004).
  20. Molina, A. J., et al. Neurotransmitter modulation of extracellular H+ fluxes from isolated retinal horizontal cells of the skate. The Journal of physiology. 560, 639-657 (2004).
  21. Marenzana, M., Shipley, A. M., Squitiero, P., Kunkel, J. G., Rubinacci, A. Bone as an ion exchange organ: evidence for instantaneous cell-dependent calcium efflux from bone not due to resorption. Bone. 37, 545-554 (2005).
  22. Lew, R. R. Ionic currents and ion fluxes in Neurospora crassa hyphae. Journal of experimental botany. 58, 3475-3481 (2007).
  23. Vieira, A. C., et al. Ionic components of electric current at rat corneal wounds. PloS one. 6, e17411 (2011).
  24. Luxardi, G., Reid, B., Maillard, P., Zhao, M. Single cell wound generates electric current circuit and cell membrane potential variations that requires calcium influx. Integrative biology : quantitative biosciences from nano to macro. 6, 662-672 (2014).
  25. Smith, P. J. S., Sanger, R. H., Messerli, M. A., Michael, A. C., Borland, L. H. . Electrochemical Methods for Neuroscience. , (2007).
  26. Smith, P. J., Hammar, K., Porterfield, D. M., Sanger, R. H., Trimarchi, J. R. Self-referencing, non-invasive, ion selective electrode for single cell detection of trans-plasma membrane calcium flux. Microscopy research and technique. 46, 398-417 (1999).
  27. Messerli, M. A., Smith, P. J. Construction theory, and practical considerations for using self-referencing of Ca(2+)-selective microelectrodes for monitoring extracellular Ca(2+) gradients. Methods in cell biology. 99, 91-111 (2010).
  28. Chambers, J., Hastie, T., Pregibon, D., Momirović, K., Mildner, V. Ch. 48. Compstat. , 317-321 (1990).
  29. Chambers, J. M., Cleveland, W. S., Kleiner, B., Tukey, P. A. . Graphical methods for data analysis. , (1983).
  30. Burkel, B. M., Benink, H. A., Vaughan, E. M., von Dassow, G., Bement, W. M. A Rho GTPase signal treadmill backs a contractile array. Developmental cell. 23, 384-396 (2012).
  31. Bement, W. M., Mandato, C. A., Kirsch, M. N. Wound-induced assembly and closure of an actomyosin purse string in Xenopus oocytes. Current biology : CB. 9, 579-587 (1999).
  32. Mandato, C. A., Bement, W. M. Contraction and polymerization cooperate to assemble and close actomyosin rings around Xenopus oocyte wounds. The Journal of cell biology. 154, 785-797 (2001).
  33. Benink, H. A., Bement, W. M. Concentric zones of active RhoA and Cdc42 around single cell wounds. The Journal of cell biology. 168, 429-439 (2005).
  34. Simon, C. M., Vaughan, E. M., Bement, W. M., Edelstein-Keshet, L. Pattern formation of Rho GTPases in single cell wound healing. Molecular biology of the cell. 24, 421-432 (2013).
  35. Petersen, C. C., Dupont, G. The initiation of a calcium signal in Xenopus oocytes. Cell calcium. 16, 391-403 (1994).
  36. Horisberger, J. D., Lemas, V., Kraehenbuhl, J. P., Rossier, B. C. Structure-function relationship of Na,K-ATPase. Annual review of physiology. 53, 565-584 (1991).
  37. Miledi, R. A calcium-dependent transient outward current in Xenopus laevis oocytes. Proceedings of the Royal Society of London. Series B, Containing papers of a Biological character. Royal Society. , 491-497 (1982).
  38. Miledi, R., Parker, I. Chloride current induced by injection of calcium into Xenopus oocytes. The Journal of physiology. 357, 173-183 (1984).
  39. Parker, I., Miledi, R. A calcium-independent chloride current activated by hyperpolarization in Xenopus oocytes. Proceedings of the Royal Society of London. Series B, Containing papers of a Biological character. Royal Society. 233, 191-199 (1988).
  40. Costa, P. F., Emilio, M. G., Fernandes, P. L., Ferreira, H. G., Ferreira, K. G. Determination of ionic permeability coefficients of the plasma membrane of Xenopus laevis oocytes under voltage clamp. The Journal of physiology. 413, 199-211 (1989).
  41. Adams, D. S., Levin, M. General principles for measuring resting membrane potential and ion concentration using fluorescent bioelectricity reporters. Cold Spring Harbor protocols. 2012, 385-397 (2012).
  42. Porterfield, D. M. Measuring metabolism and biophysical flux in the tissue, cellular and sub-cellular domains: recent developments in self-referencing amperometry for physiological sensing. Biosensors. 22, 1186-1196 (2007).
  43. McLamore, E. S., et al. A self-referencing glutamate biosensor for measuring real time neuronal glutamate flux. Journal of neuroscience methods. 189, 14-22 (2010).
  44. Yin, M., et al. Highly sensitive and fast responsive fiber-optic modal interferometric pH sensor based on polyelectrolyte complex and polyelectrolyte self-assembled nanocoating. Analytical and bioanalytical chemistry. 399, 3623-3631 (2011).
  45. Chatni, M. R., Porterfield, D. M. Self-referencing optrode technology for non-invasive real-time measurement of biophysical flux and physiological sensing. The Analyst. 134, 2224-2232 (2009).
  46. McLamore, E. S., Jaroch, D., Chatni, M. R., Porterfield, D. M. Self-referencing optrodes for measuring spatially resolved, real-time metabolic oxygen flux in plant systems. Planta. 232, 1087-1099 (2010).
  47. McLamore, E. S., et al. A self referencing platinum nanoparticle decorated enzyme-based microbiosensor for real time measurement of physiological glucose transport. Biosensors & bioelectronics. 26, 2237-2245 (2011).
check_url/52782?article_type=t

Play Video

Cite This Article
Luxardi, G., Reid, B., Ferreira, F., Maillard, P., Zhao, M. Measurement of Extracellular Ion Fluxes Using the Ion-selective Self-referencing Microelectrode Technique. J. Vis. Exp. (99), e52782, doi:10.3791/52782 (2015).

View Video