A subscription to JoVE is required to view this content. Sign in or start your free trial.

Method Article

Technical Detail for Robot Assisted Pancreaticoduodenectomy

14.2K views

⸱

DOI:

10.3791/60261

⸱

September 28th, 2019

 ,  , 

In This Article

Summary

The following manuscript details a stepwise approach to the robot-assisted pancreaticoduodenectomy performed at the University of Pittsburgh Medical Center.

Abstract

Since its first report in 2003, robotic pancreaticoduodenectomy (RPD) has gained popularity among pancreatic surgeons. Inherent advantages of the robotic platform, including three-dimensional vision, wristed instruments, and improved ergonomics, allow the surgeon to recapitulate the principles of open pancreatoduodenectomy allowing safe oncologic dissection, hemostasis, and meticulous reconstruction. Over the course of the past decade, significant strides have been achieved in outlining the safety, feasibility, and learning curve of the robotic Whipple. When performed by high volume pancreatic surgeons experienced in RPD, recent comparative effectiveness studies show potential advantages compared to the open technique, including reductions in hospital stay and morbidity. National data also show reductions in conversion rates compared to its laparoscopic counterpart. Although long-term oncologic data are still needed, short-term oncologic surrogates of margin resection and lymph node harvest suggest no compromise in oncologic outcomes. As pancreatic surgeons increasingly integrate robotics into their practice, proficiency-based training and credentialing will be necessary for the safe application and dissemination of RPD. Here, we provide the detailed steps of a robotic pancreaticoduodenectomy performed at the University of Pittsburgh Medical Center. 

Introduction

Pancreaticoduodenectomy (PD) is a complex operation that combines a challenging resection and a meticolous reconstruction. During its early inception, the traditional open approach was frought with high complication rates and a mortality rate approaching 25%. In the last three decades, improvements in the surgical technique and perioperative care led to corresponding improvements in outcomes, with a reduction in mortality to less than 5%, especially at high volume centers1,2,3. Despite this, morbidity remains substantial. With advancements in surgical technology, minimally in....

Access restricted. Please log in or start a trial to view this content.

Protocol

This protocol follows the guidelines of the University of Pittsburg Medical Center human research ethics comittee (Institutional Review Board: PRO15040497)

1. Preoperative workup and selection

  1. Check the triphasic CT scan (i.e., chest, abdomen, and pelvis with the primary imaging modality) to evaluate the extent of disease, rule out metastasis, and delineate aberrant or anomalous arterial vasculature. 
  2. Perform EUS and endoscopic retrograde cholangiopancreatography (ERCP) for the tissue diagnosis and biliary decompression, especially in the setting of the planned neoadjuvant chemotherapy for pancreatic cancer.
  3. ....

Access restricted. Please log in or start a trial to view this content.

Results

In the representative case, the total operative time was 225 min with an estimated blood loss (EBL) of 50 mL (Table 1). The patient was admitted to the surgical ward. Her postoperative course followed the UPMC institutional ERAS pathway. We routinely assess JP amylase at POD#1 and #3 to assess for pancreatic fistula and practice early drain removal on POD 3-5 when possible. The patient’s JP amylase levels were 403 U/L and 68 U/L, respectively. Therefore, the drain was removed on POD#3. The patient was di.......

Access restricted. Please log in or start a trial to view this content.

Discussion

With advances in the surgical technology, laparoscopic and robot-assisted surgeries are being increasingly used in gastrointestinal and hepatobiliary procedures. Conventional laparoscopy is associated with benefits over open surgery for many procedures. However, inherent limitations such as decreased surgical dexterity, suboptimal ergonomics, lack of wristed instruments, and 2-D visualization, have limited its dissemination to complex gastrointestinal operations such as PD. 

Contrary to l.......

Access restricted. Please log in or start a trial to view this content.

Disclosures

Nothing to disclose.

Acknowledgements

Nothing to acknowledge.

....

Access restricted. Please log in or start a trial to view this content.

Materials

List of materials used in this article
NameCompanyCatalog NumberComments
3-0 V-Loc suturesMedtronic (Minneapolis, MN)VLOCMo614Barbed Absorable Suture
4-5 Fr Freeman Pancreatic Flexi-StentHobbs Medical (Stafford Springs, CT)6542, 6552Pancreatic Duct Stent
5-0 PDS (polydiosxanone)Ethicon (Somerville, NJ)D10063Synthetic Absorbable Suture
Cadíere forcepsIntuitive (Sunnyvale, CA)470049Surgical Robot Instrument
Da Vinci SiIntuitive (Sunnyvale, CA)Surgical Robot
Da Vinci XiIntuitive (Sunnyvale, CA)Surgical Robot
Endo Clip 10 mm ApplierCovidien (Dublin, Ireland)176619Laparoscopic Titanium Clip Applier
Endo GIA 45 mm Curved Tip Articulating Vascular Stapler with Tri-Stapler TechnologyCovidien (Dublin, Ireland)EGIA45CTAVMLaparoscopic Surgical Stapler
Endo GIA 60 mm Articulating Stapler with Tri-Stapler TechnologyCovidien (Dublin, Ireland)EGIA60AMTLaparoscopic Surgical Stapler
Endo GIA 60 mm Curved Tip Articulating Vascular Stapler with Tri-Stapler TechnologyCovidien (Dublin, Ireland)EGIA60CTAVMLaparoscopic Surgical Stapler
EndoCatch Gold 10 mm Specimen PouchMedtronic (Minneapolis, MN)173050GSpecimen Extraction Bag
EndoCatch II 15 mm Specimen PouchMedtronic (Minneapolis, MN)173049Specimen Extraction Bag
Fenestrated bipolar forcepsIntuitive (Sunnyvale, CA)470205Surgical Robot Instrument
GelPOINT Mini Advanced Access PlatformApplied Medical (Rancho Santa Margarita, CA)CNGL3Laparoscopic Abdominal Access Platform
Large needle driverIntuitive (Sunnyvale, CA)470006Surgical Robot Instrument
Large SutureCut needle driverIntuitive (Sunnyvale, CA)470296Surgical Robot Instrument
LigaSure Blunt Tip Laparoscopic Sealer/DividerMedtronic (Minneapolis, MN)LF1844Laparoscopic Bioplar Device
Mediflex liver retractorMediflex (Islandia NY)Laparoscopic Liver Retractor
Monopolar curved scissorsIntuitive (Sunnyvale, CA)470179Surgical Robot Instrument
Permanent cautery hookIntuitive (Sunnyvale, CA)470183Surgical Robot Instrument
ProGrasp forcepsIntuitive (Sunnyvale, CA)470093Surgical Robot Instrument

References

  1. Tseng, J. F., et al. The learning curve in pancreatic surgery. Surgery. 141, 456-463 (2007).
  2. Cameron, J. L., He, J. Two Thousand Consecutive Pancreaticoduodenectomies. Journal of the American College of Surgeons. 220, 530-536 (2015).
  3. Birkmeyer, J., ....

Access restricted. Please log in or start a trial to view this content.

Reprints and Permissions

Explore More Articles

Robotic PancreaticoduodenectomyPancreatic ResectionVascular StaplerKocherizationPortal Vein DissectionPancreaticojejunostomyHepaticojejunostomyGastrojejunostomyLigament of TreitzUncinate Process