Summary

Microfluidic Flusso Camere con sangue ricostituito al modello Emostasi e piastrine Transfusion<em> In Vitro</em

Published: March 19, 2016
doi:

Summary

Platelet transfusion and hemostasis was modeled using blood reconstitution and microfluidic flow chambers to investigate the function of blood banking platelets. The data demonstrate the consequences of platelet storage lesion on hemostasis, in vitro.

Abstract

Blood platelets prepared for transfusion gradually lose hemostatic function during storage. Platelet function can be investigated using a variety of (indirect) in vitro experiments, but none of these is as comprehensive as microfluidic flow chambers. In this protocol, the reconstitution of thrombocytopenic fresh blood with stored blood bank platelets is used to simulate platelet transfusion. Next, the reconstituted sample is perfused in microfluidic flow chambers which mimic hemostasis on exposed subendothelial matrix proteins. Effects of blood donation, transport, component separation, storage and pathogen inactivation can be measured in paired experimental designs. This allows reliable comparison of the impact every manipulation in blood component preparation has on hemostasis. Our results demonstrate the impact of temperature cycling, shear rates, platelet concentration and storage duration on platelet function. In conclusion, this protocol analyzes the function of blood bank platelets and this ultimately aids in optimization of the processing chain including phlebotomy, transport, component preparation, storage and transfusion.

Introduction

Emostasi richiede l'attività combinata e regolata di cellule, proteine, ioni e tessuti in un contesto spazio-temporale limitato 1. Attività incontrollata può portare a emorragia o trombosi e morbilità o mortalità in uno spettro di disturbi legati alla coagulazione del sangue. Un esperimento camera di flusso microfluidica è una tecnica impegnativa che imita emostasi in vitro. Questo approccio permette di indagine della complessa interazione di processi che prendono parte a emostasi con un ruolo di primo piano per le piastrine del sangue.

A seguito di danno vascolare, le piastrine aderiscono alle proteine ​​della matrice sottoendoteliale esposto (glico) per prevenire la perdita di sangue. Dopo l'adesione, piastrine attivano e aggregate in risposta automatiche e segnalazione paracrina che alla fine porta alla formazione di una rete di piastrine, stabilizzata da fibrina e conseguente fermo, avvolti trombo 2 sigillatura. A differenza di molti altri test di funzionalità piastrinica, rienzementi con camere di flusso tengono conto del parametro fisico del flusso sanguigno e quindi l'influenza della reologia sulle cellule e biomolecole 3,4 partecipanti.

esperimenti camera di flusso hanno generato intuizioni punto di riferimento in emostasi e trombosi variando i parametri chiave che influenzano emostatico (sub) processi tra cui i profili matrice adesiva, reologia e di flusso, composizione cellulare, la presenza di tossine o farmaci, forza ionica e molti altri. Negli ultimi due decenni, bassa produttività esperimenti camera di flusso che richiedono grandi volumi di campione (10-100 ml) si sono evoluti per camere di microfluidica spesso costituite da piccole camere a piatti paralleli e tra le moderne tecnologie per la perfusione di sangue intero in condizioni di parete di taglio a controllo 5. Microscaling ha notevolmente aumentato il throughput test soprattutto perché la configurazione hardware è semplificato ed è richiesto meno (del sangue) del volume, rendendo l'esperimento più accessibile e versatiLe. Per esempio, il sangue da piccoli animali da laboratorio può ora essere utilizzato senza dover sacrificare animali. I campioni di sangue di topi geneticamente modificati hanno quindi aiutato l'identificazione di molecole chiave che promuovono o inibiscono emostasi e in nuove intuizioni fondamentali 6.

Laboratori di ricerca specializzati spesso usano ancora camere a flusso su misura, ad esempio, da polidimetilsilossano (PDMS) 7 che polimerizza su stampi litografate che può essere blueprinted da un software. La camera risultante è poco costoso, monouso e può essere facilmente smontato per l'analisi post hoc. Inoltre, in pratica qualsiasi progettazione di navi, comprese le biforcazioni o curve strette può essere costruito su comando. Questo vantaggio è anche il suo lato negativo in quanto la standardizzazione era già il problema principale con gli esperimenti camera di flusso, e PDMS su misura le camere non hanno aiutato questo. In cima a questa particolare questione, rivestimento (condizioni), sonde fluorescenti, anticoagulante, temperaturaeratura e ora tra il campionamento e l'analisi sono tutti poco standardizzati 8. La standardizzazione di queste variabili è impegnativo, ma comunque atti a consentire un confronto dei risultati tra laboratori. Questo argomento è il principale soggetto della Società Internazionale sulla Trombosi e Emostasi in sottocomitato scientifico e standardizzazione su Biorheology 9,10.

concentrati piastrinici (PC) sono trasfusi in pazienti affetti da varie malattie che causano trombocitopenia e / o sanguinamento. Ma piastrine in PC sono noti per desensibilizzare, soprattutto in funzione del tempo di memorizzazione 11, un processo di degrado legato all'invecchiamento e comunemente indicato come lesione stoccaggio delle piastrine. A volte si afferma che tali piastrine ripristinare in circolazione una volta trasfuse 12, ma la prova di questo è scarsa. Inoltre, la funzionalità delle piastrine che compongono un PC non è normalmente testato perché il rapporto tra tali analisi eefficacia terapeutica o profilattica non è chiaro 13. camere di flusso microfluidica offrono un mezzo per indagare la funzione piastrinica in PC per ottimizzare la catena di manipolazioni tra raccolta e rilascio. Si tratta di un potente strumento di ricerca per (appaiati) il confronto diretto dei PC, come abbiamo precedentemente pubblicati 14,15 ed è descritto qui.

Protocol

Questo protocollo segue le linee guida etiche istituzionali per la ricerca su campioni umani e il consenso informato è stato ottenuto da tutti i donatori coinvolti. L'approvazione per gli esperimenti descritti qui è stato ottenuto dal Comitato Etico dell'Ospedale di Anversa University. Nota: le indicazioni di temperatura sono sempre a temperatura ambiente, se non diversamente specificato. Installazione 1. Preparazione camera di flusso Lanes P…

Representative Results

Per dimostrare la variazione intra-saggio, tre identici campioni di sangue intero sono stati ricostituiti perfusi simultaneamente su superfici di collagene rivestito (Figura 1). Ciò ha determinato un coefficiente di variazione del 8,7%. Questa statistica suggerisce accettabile intra-saggio e la variazione intralaboratorio permettendo il confronto affidabile tra i campioni relativi. L'entrata della camera …

Discussion

Esperimenti camera di flusso microfluidici sono un ottimo strumento per studiare la funzione delle piastrine nel sangue che scorre e sono utilizzate per valutare l'emostasi in vitro in diversi contesti sperimentali. Nonostante scarsa standardizzazione interlaboratorio 9, dimostriamo che all'interno del nostro laboratorio la variazione sperimentale è accettabile. Questo permette di confrontare in modo affidabile campioni (appaiati) all'interno di un determinato studio. Questo è stato con…

Disclosures

The authors have nothing to disclose.

Acknowledgements

The authors have no acknowledgements.

Materials

BD vacutainer tube with EDTA  Becton, Dickinson and Company 368856
BD vacutainer tube with Heparin Becton, Dickinson and Company 368480
BD vacutainer tube with Sodium Citrate Becton, Dickinson and Company 366575
Hirudin Blood tube Roche 6675751 001
BD vacutainer Eclipse Becton, Dickinson and Company 368650 Blood collection needle with preattached holder
Pipette tips 100-1000 Greiner bio-one 740290
Pipette tips 2-200 Greiner bio-one 739280
Pipette tips 1-10 Eppendorf A08928
Tube 5mL Simport 11691380
Conical tube 15mL Greiner bio-one 1888271
Conical tube 50mL Greiner bio-one 227261
10 mL Syringe BD 309604
Precision wipes Kimtech 5511
Vena8 Fluoro+ Biochips Cellix 188V8CF-400-100-02P10 Named in figure S1 A as 'Biochip'
Vena8 Tubing Cellix TUBING-TYGON-B1IC-B1OC-ROLL 100F Named in figure S1 B as 'Disposable tubing'
Vena8 Needles Cellix SS-P-B1IC-B1OC-PACK200 Named in figure S1 B as 'Pin'
Connectors for single inlet cables of biochips Cellix CONNECTORS-B1IC-PACK100
Multiflow8 connect Cellix MF8-CONNECT-BIC3-N-THROMBOSIS Named in figure S1 B as 'Reusable tubing' and 'Splitter'
Humidified box Cellix HUMID-BOX
Software microfluidic pump Cellix N/A Venaflux Assay
Horm Collagen Takeda/Nycomed 1130630 Native equine tendon collagen (type I)
Isotonic glucose solution to dilute collagen is supplemented
HEPES buffered saline (HBS) in house preparation in house preparation 10mM 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) buffered saline (0.9% (w/v) NaCl, pH 7.4
Blocking buffer in house preparation in house preparation 1.0% (w/v) bovine serum albumin and 0.1% (w/v) glucose in HBS
Calcein AM Molecular probes C1430
Bleach 10% in house preparation in house preparation
0.1M NaOH in house preparation in house preparation
Denaturated alcohol Fiers T0011.5
Mirus Evo Nanopump Cellix 188-MIRUS-PUMP-EVO with Multiflow8. Named in figure S1 A as 'Pump' and 'Manifold'
Microscope Zeiss Axio Observer Z1 equipped with a colibri-LED and high resolution CCD camera
Software microscope  Zeiss N/A ZEN 2012
Hematology analyzer Sysmex N/A
Table Top Centrifuge Eppendorf 521-0095
Platelet incubater Helmer PF-48i
Incubation water bath GFL 1013
Pipette Brand A03429
Tube Roller Ratek BTR5-12V
Sterile docking device Terumo BCT TSCD
Tubing Sealer Terumo BCT AC-155
Vortex VWR 58816-121

References

  1. Broos, K., Feys, H. B., De Meyer, S. F., Vanhoorelbeke, K., Deckmyn, H. Platelets at work in primary hemostasis. Blood Rev. 25, 155-167 (2011).
  2. Stalker, T. J., et al. Hierarchical organization in the hemostatic response and its relationship to the platelet-signaling network. Blood. 121, 1875-1885 (2013).
  3. Sakariassen, K. S., Bolhuis, P. A., Sixma, J. J. Human blood platelet adhesion to artery subendothelium is mediated by factor VIII-Von Willebrand factor bound to the subendothelium. Nature. 279, 636-638 (1979).
  4. Savage, B., Saldivar, E., Ruggeri, Z. M. Initiation of platelet adhesion by arrest onto fibrinogen or translocation on von Willebrand factor. Cell. 84, 289-297 (1996).
  5. Westein, E., de Witt, S., Lamers, M., Cosemans, J. M., Heemskerk, J. W. Monitoring in vitro thrombus formation with novel microfluidic devices. Platelets. 23, 501-509 (2012).
  6. Varga-Szabo, D., et al. The calcium sensor STIM1 is an essential mediator of arterial thrombosis and ischemic brain infarction. J Exp Med. 205, 1583-1591 (2008).
  7. Westein, E., et al. Atherosclerotic geometries exacerbate pathological thrombus formation poststenosis in a von Willebrand factor-dependent manner. Proc Natl Acad Sci USA. , (2013).
  8. Grabowski, E. F., Yam, K., Gerace, M. Evaluation of hemostasis in flowing blood. Am J Hematol. 87 (Suppl 1), S51-S55 (2012).
  9. Roest, M., et al. Flow chamber-based assays to measure thrombus formation in vitro: requirements for standardization. J Thromb Haemost. 9, 2322-2324 (2011).
  10. Heemskerk, J. W. M., et al. Collagen surfaces to measure thrombus formation under flow: possibilities for standardization. J Thromb Haemost. 9, 856-858 (2011).
  11. Shrivastava, M. The platelet storage lesion. Transfus Apher Sci. 41, 105-113 (2009).
  12. Miyaji, R., et al. Decreased platelet aggregation of platelet concentrate during storage recovers in the body after transfusion. Transfusion. 44, 891-899 (2004).
  13. Goodrich, R. P., et al. Correlation of in vitro platelet quality measurements with in vivo platelet viability in human subjects. Vox Sang. 90, 279-285 (2006).
  14. Van Aelst, B., et al. Riboflavin and amotosalen photochemical treatments of platelet concentrates reduce thrombus formation kinetics in vitro. Vox Sang. 108, 328-339 (2015).
  15. Van Aelst, B., Devloo, R., Vandekerckhove, P., Compernolle, V., Feys, H. B. Ultraviolet c light pathogen inactivation treatment of platelet concentrates preserves integrin activation but affects thrombus formation kinetics on collagen in vitro. Transfusion. , (2015).
  16. de Witt, S. M., et al. Identification of platelet function defects by multi-parameter assessment of thrombus formation. Nat Commun. 5, 4257 (2014).
  17. Cazenave, J. P., et al. Preparation of washed platelet suspensions from human and rodent blood. Methods Mol Biol. 272, 13-28 (2004).
  18. Jackson, S. P., Nesbitt, W. S., Westein, E. Dynamics of platelet thrombus formation. J Thromb Haemost. 7 (Suppl 1), 17-20 (2009).
  19. Diedrich, B., Remberger, M., Shanwell, A., Svahn, B. M., Ringden, O. A prospective randomized trial of a prophylactic platelet transfusion trigger of 10 x 10(9) per L versus 30 x 10(9) per L in allogeneic hematopoietic progenitor cell transplant recipients. Transfusion. 45, 1064-1072 (2005).
  20. Neeves, K. B., et al. Sources of variability in platelet accumulation on type 1 fibrillar collagen in microfluidic flow assays. PloS one . 8, e54680 (2013).
  21. Born, G. V. Aggregation of blood platelets by adenosine diphosphate and its reversal. Nature. 194, 927-929 (1962).
  22. Cattaneo, M., et al. Recommendations for the Standardization of Light Transmission Aggregometry: A Consensus of the Working Party from the Platelet Physiology Subcommittee of SSC/ISTH. J Thromb Haemost. 11, 1183-1189 (2013).
  23. Deckmyn, H., Feys, H. B. Assays for quality control of platelets for transfusion. ISBT Sci Series. 8, 221-224 (2013).
  24. Andre, P., et al. Anticoagulants (thrombin inhibitors) and aspirin synergize with P2Y12 receptor antagonism in thrombosis. Circulation. 108, 2697-2703 (2003).
  25. Casari, C., et al. von Willebrand factor mutation promotes thrombocytopathy by inhibiting integrin alphaIIbbeta3. J Clin Invest. 123, 5071-5081 (2013).
  26. Gitz, E., et al. Improved platelet survival after cold storage by prevention of Glycoprotein Ibα clustering in lipid rafts. Haematologica. , (2012).
  27. Maurer-Spurej, E., Labrie, A., Brown, K. Routine Quality Testing of Blood Platelet Transfusions with Dynamic Light Scattering. Part Part Syst Char. 25, 99-104 (2008).
  28. Van Kruchten, R., Cosemans, J. M., Heemskerk, J. W. Measurement of whole blood thrombus formation using parallel-plate flow chambers – a practical guide. Platelets. 23, 229-242 (2012).
  29. Zwaginga, J. J., et al. Flow-based assays for global assessment of hemostasis. Part 2: current methods and considerations for the future. J Thromb Haemost. 4, 2716-2717 (2006).
  30. Zwaginga, J. J., et al. Flow-based assays for global assessment of hemostasis. Part 1: Biorheologic considerations. J Thromb Haemost. 4, 2486-2487 (2006).

Play Video

Cite This Article
Van Aelst, B., Feys, H. B., Devloo, R., Vandekerckhove, P., Compernolle, V. Microfluidic Flow Chambers Using Reconstituted Blood to Model Hemostasis and Platelet Transfusion In Vitro. J. Vis. Exp. (109), e53823, doi:10.3791/53823 (2016).

View Video