Summary

Here, a method that enables quick, efficient, and inexpensive preparation of polyacrylamide gels in a multiwell plate format is described. The method does not require any specialized equipment and could be easily adopted by any research laboratory. It would be particularly useful in research focused on understanding stiffness-dependent cell responses.

Abstract

Currently, most of the in vitro cell research is performed on rigid tissue culture polystyrene (~1 GPa), while most cells in the body are attached to a matrix that is elastic and much softer (0.1 – 100 kPa). Since such stiffness mismatch greatly affects cell responses, there is a strong interest in developing hydrogel materials that span a wide range of stiffness to serve as cell substrates. Polyacrylamide gels, which are inexpensive and cover the stiffness range of all soft tissues in the body, are the hydrogel of choice for many research groups. However, polyacrylamide gel preparation is lengthy, tedious, and only suitable for small batches. Here, we describe an assay which by utilizing a permanent flexible plastic film as a structural support for the gels, enables the preparation of polyacrylamide gels in a multiwell plate format. The technique is faster, more efficient, and less costly than current methods and permits the preparation of gels of custom sizes not otherwise available. As it doesn’t require any specialized equipment, the method could be easily adopted by any research laboratory and would be particularly useful in research focused on understanding stiffness-dependent cell responses.

Introduction

Die meisten Gewebe im Körper weich sind viskoelastische Materialien mit einem Young-Modul im Bereich von 0,1 kPa für Gehirn bis 100 kPa für weiche Knorpel, doch sind die meisten in vitro Zellforschung auf Gewebekulturpolystyrol (TCP) durchgeführt, die einen Modul von ~ 1 GPa hat . 1 Diese Steifigkeit Mismatch großen Einfluss auf die Art und Weise Zellen reagieren auf ihre Umwelt. Eine wachsende Zahl von Untersuchungen ist somit gewidmet Erläuterung der Wirkung des Substrats Steifigkeit auf das Schicksal verschiedener Zelltypen, 2,3 einschließlich Stammzellen. 4 Als Ergebnis wurden mehrere Hydrogele entwickelt worden, um das Verständnis der steifigkeitsabhängigen Zell helfen Biologie einschließlich Polyacrylamid (PA), 5-7 Polyethylenglykol (PEG) 8,9 Polydimethylsiloxan (PDMS), 10 und Alginat. 11 Während der Beweis, dass das Substrat Steifigkeit hat einen wesentlichen Einfluss auf das Schicksal der Zelle wächst, die meisten Untersuchungen auf geführt in kleinem Maßstab mit einer kleinen Anzahl von sBeispiele. Systematische, mehrdimensionalen Studien über die Wirkung der Substrat Steifigkeit für eine Reihe von Zelltypen oder Umweltbedingungen selten. 12

Einige vielversprechende Hochdurch Hydrogel Technologien wurden entwickelt, einschließlich PEG-Microarrays, 13 mikrofluidischen Vorrichtungen zur Herstellung von Agarose Hydrogelmikroperlen, 14 oder Mikro- und Nanostäbe denen Steifigkeit wird durch den Durchmesser und die Höhe der Mikrostäbchen moduliert. 15. Jedoch , die Technologien zur Herstellung solcher Substrate sind anspruchsvoll und für eine begrenzte Anzahl von Laboratorien. Viel Forschung an Steifigkeit moduliert Zell-Reaktionen nutzt Polyacrylamid (PA) Gele, die nicht nur preiswert und einfach zu implementieren, aber auch zeigen einen physiologisch relevanten Bereich des E-Moduls, nämlich 0,3 liegen. – 300 kPa 16 bis 22 jedoch bestehende Methoden zu PA herzustellen Gele für die Zellkultur sind arbeitsintensiv und damit prepin kleinen Chargen ared. Einige der Schwierigkeiten, die mit der Herstellung von PA-Gelen als Zellsubstrate zugeordnet ergeben sich aus der Forderung, daß die Gele hergestellt werden müssen: 1) in Abwesenheit von Sauerstoff, um eine vollständige Polymerisation zu ermöglichen, 2) mit einer flachen und glatten Oberfläche, um eine einheitliche Zell ermöglichen Befestigung und Ausbreitung, und 3) fest auf dem Boden der Zellkulturschale Aufschwimmen verhindern befestigt.

Mehrere Gruppen haben versucht, PA-Gele für die Zellkultur in großen Stückzahlen zu produzieren. Semler et al. Vorbereiteten dicken Folien aus PA-Gelen, die dann einen "Schnitt" waren mit einem Locher und in 96-Well-Platten gegeben. 23. Dieses Verfahren ist jedoch begrenzt auf steifer Gele, dh> 1 kPa im Elastizitätsmodul, da weichere Gele sind "sticky", schwierig zu schneiden und leicht beschädigt. Mih et al. Entwickelten eine ausgefeiltere Technik, die Gele direkt in einem Glasbodenmultiwellplatte polymerisiert werden können. <sbis> 6 Dies erfolgte, indem die Gel-Lösungen in funktionalisierte Glasbodenplatten und Bildung von Gelen von "sandwichartig" sie mit einem benutzerdefinierten Deckglas Array erreicht. 6 Obwohl vielversprechend, leichte Randeffekte waren noch mit dieser Technik beobachtet. Zusätzlich wird die Technik erfordert eine maßgeschneiderte Array nicht unmittelbar zugänglich vielen Labors als auch kostspielige Glasbodenmultiwellplatten.

Dieser Aufsatz beschreibt eine einfache und kostengünstige Möglichkeit, PA-Gelen in einer Multiwellplatte, die leicht von jedem Labor angenommen werden könnte zubauen. Hierbei wird eine flexible Kunststoffunterlage verwendet wird, welches zwei Seiten hat – ein hydrophobes, die abweisend zu PA-Gelen, und einem hydrophilen eine, an das kovalent das PA-Gel bei der Abscheidung. Sobald PA Gelfolien abgeschieden und dauerhaft mit dem flexiblen Kunststoffträger befestigt sind, ermöglicht es der Handhabung Gele beliebiger Dicke oder Steifigkeit und schneidet sie in jede gewünschte Form. Diese ca.oach erzeugt nicht nur individuelle Kunststoff 'Deck' in Größen im Handel nicht erhältlich, sondern auch beseitigt die Notwendigkeit, Glasoberflächen-treat vorab entweder Glasplättchen oder die Vertiefungen der teuren Glasboden-Mikrotiterplatten mit einer PA-Bindungslösung, welche ist eine mühsame und zeitraubenden Schritt. Schließlich kann eine gleichmäßige PA Gele Blätter in großen Stückzahlen hergestellt und gelagert de-hydrierten mehrere Monate werden.

Zusammenfassend ist der Assay hier vorgestellt ist eine Verbesserung gegenüber bestehenden Verfahren in mehrfacher Hinsicht. Erstens ist der Prozeß der Vielmuldenplatten-Anordnung effizient, und die Gesamtkosten der benötigten Materialien ist gering. Zweitens werden die Hydrogele in großen Chargen in einem einzigen homogenen Gelfilm hergestellt. Schließlich werden nur Materialien, die im Handel erhältlich sind erforderlich. Die Nützlichkeit des Assays wird durch die Erforschung der Wirkung des Substrats Steifigkeit auf die Zellmorphologie und die Ausbreitungsfläche dargestellt.

Protocol

1. Herstellung der Hydrogel-assoziierten Solutions und Aliquots Herstellung Polyacrylamidgel Precursorlösung. Bereiten Polyacrylamidgel Vorläuferlösung durch Mischen Acrylamid (A) (40% w / v, M r 71.08 g / mol), das Vernetzungs Bisacrylamid (B) (2% w / v, M r 154.17 g / mol), und Ent- entionisiertes Wasser in den in Tabelle 1 angegebenen Volumenanteile. ANMERKUNG: Diese Lösungen können in großen Serien hergestellt und bei 4 ° C für bis zu mehreren…

Representative Results

Polyacrylamid (PA) Hydrogele werden allgemein verwendet, um die Steifigkeit abhängige Zell-Reaktionen zu testen. 17,24 durch Mischen verschiedener Konzentrationen von Acrylamid (A) und bis-acrylamid (B) kann man PA-Gelen, welche die Steifigkeit Bereich der meisten Weichgewebe in umspannen machen der Körper – 0,3 -. 300 1 ist jedoch Herstellung Polyacrylamidgelen mühsam und zeitaufwendig, häufig ihre Nützlichkeit in "Hochdurchsatz" Anwendungen, wie zum Beispiel Arzneimittel-Screening …

Discussion

Polyacrylamid-Gele, die ursprünglich für die Elektrophorese entwickelten, 28 werden nun routinemßig als Zellkultursubstrate verwendet werden, um die Auswirkungen von Substrat Steifigkeit auf die Zellmorphologie, Motilität und Kommunikations 3,24,29 unter anderem Zelleigenschaften zu untersuchen. Polyacrylamid ermöglicht die Bearbeitung der Substratsteifigkeit um die Steifigkeit aller Weichteile im Körper umfassen (0,3 bis 300 kPa) 1 mit einer einfachen Änderung der Polymervorstufe…

Divulgaciones

The authors have nothing to disclose.

Acknowledgements

This work was funded by start-up funds provided to Dr. Silviya Zustiak by Saint Louis University as well as by a President’s Research Fund (PRF) grant awarded to Dr. Silviya Zustiak by Saint Louis University. We thank Naveed Ahmed and Keval Shah for technical assistance.

Materials

Reagents
40% Acrylamide Bio-Rad 161-0140
2% Bis-acrylamide Bio-Rad 161-0142
Ammonium Persulfate Bio-Rad 161-07000
TEMED Sigma Aldrich T9281
Sulfo-SANPAH Thermo Scientific 22589
Collagen Type 1, from Rat tail, 3.68 mg/mL BD Biosciences 354236
Dimethyl sulfoxide (DMSO) Fisher Scientific  BP231-100
Hydrophobic solution – Repel Silane  GE Healthcare Bio-Sciences 17-1332-01
PBS (1x), pH 7.4 HyClone SH30256.01
Polydimehylsiloxane (PDMS) [Slygard 182 Elastomer Kit] Elsworth Adhesives 3097358-1004
Tyrpsin/EDTA (10x) Sigma Aldrich 44174
RPMI-1640 Medium (1x) HyClone SH30027-02
Fetal Bovine Serum HyClone SH30073-03
Penicillin Streptomycin MP Biomedicals 1670046
Detergent – Triton-X Sigma Aldrich T8787
Formaldehyde 37% Solution Sigma Aldrich F1635
Bovine Serum Albumin (BSA) Sigma Aldrich A2153
BSA-based cell adhesion blocking kit – ECM Cell Adhesion Array Kit Chemicon International ECM540
Disposable lab equipment
flexible plastic support – GelBond PAG Film for Polyacrylamide Gels GE Healthcare Bio-Sciences 309819
Glass Plates Slumpys GBS4100SFSL
50 mL Conicals Fisher Scinetific 3181345107
15 mL Conicals FALCON 352097
Micro centrifuge tubes Fisher Scinetific 2 mL: 02681258
96-well plate (flat bottom) Fisher Scinetific 12565501
Disposable Pipettes (1 mL, 2mL, 5mL, 10mL, 25 mL, 50mL) Fisher Scinetific 1 mL: 13-678-11B, 2mL: 05214038, 5mL(FALCON): 357529, 10mL: 13-678-11E, 25mL: 13-678-11, 50mL: 13-678-11F
Glass Transfer Pipettes Fisher Scinetific 5 3/4": 1367820A, 9":136786B
Pipette Tips (1-200uL, 101-1000uL) Fisher Scinetific 2707509
Plastic Standard Disposable Transfer Pipettes Fisher Scientific 13-711-9D
Parafilm PARAFILM  PM992
Powder Free Examination Gloves Quest 92897
Silicone spacers – Silicone sheet, 0.5 mm thick/13 cm x 18 cm Grace Bio-Labs JTR-S-0.5
Large/non-disposable lab equipment
Light and Flourescent Microscope (Axiovert 200M) Zeiss 3820005619
Microscope Software Zeiss AxioVision Rel. 4.8.2
UV oven UVITRON UV1080
Vacuum chamber/degasser BelArt 999320237
Vacuum pump for degasser KNF Lab 5097482
Tissue Culture Hood NUAIRE NU-425-600
Chemical Fume Hood KEWAUNEE 99151
Inverted Microscope (Axiovert 25) Zeiss 663526
Incubator NUAIRE NU-8500
Pipette Aid Drummond Scientific Co. P-76864
Hemacytometer Bright-Line 383684

Referencias

  1. Levental, I., Georges, P. C., Janmey, P. A. Soft biological materials and their impact on cell function. Soft Matter. 3, 299-306 (2007).
  2. Minton, K. Mechanotransduction: A stiff response. Nature Reviews Molecular Cell Biology. 15 (8), 500-500 (2014).
  3. Yeung, T., et al. Effects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion. Cell motility and the cytoskeleton. 60 (1), 24-34 (2005).
  4. Watt, F. M., Huck, W. T. Role of the extracellular matrix in regulating stem cell fate. Nature Reviews Molecular Cell Biology. 14 (8), 467-473 (2013).
  5. Zustiak, S., Nossal, R., Sackett, D. L. Multiwell stiffness assay for the study of cell responsiveness to cytotoxic drugs. Biotechnology and bioengineering. 111 (2), (2014).
  6. Mih, J. D., et al. A multiwell platform for studying stiffness-dependent cell biology. PLoS One. 6 (5), e19929 (2011).
  7. Sunyer, R., Jin, A. J., Nossal, R., Sackett, D. L. Fabrication of hydrogels with steep stiffness gradients for studying cell mechanical response. PloS one. 7 (10), e46107 (2012).
  8. Herrick, W. G., et al. PEG-phosphorylcholine hydrogels as tunable and versatile platforms for mechanobiology. Biomacromolecules. 14 (7), 2294-2304 (2013).
  9. Tokuda, E. Y., Leight, J. L., Anseth, K. S. Modulation of matrix elasticity with PEG hydrogels to study melanoma drug responsiveness. Biomaterials. 35 (14), 4310-4318 (2014).
  10. Feng, J., et al. Substrate stiffness influences the outcome of antitumor drug screening in vitro. Clinical hemorheology and microcirculation. 55 (1), 121-131 (2013).
  11. Ramamoorthi, K., Hara, J., Ito, C., Asuri, P. Role of Three-Dimensional Matrix Stiffness in Regulating the Response of Human Neural Cells to Toxins. Cellular and Molecular Bioengineering. 7 (2), 1-7 (2014).
  12. Tilghman, R. W., et al. Matrix rigidity regulates cancer cell growth and cellular phenotype. PloS one. 5 (9), e12905 (2010).
  13. Gobaa, S., et al. Artificial niche microarrays for probing single stem cell fate in high throughput. Nature methods. 8 (11), 949-955 (2011).
  14. Kumachev, A., et al. High-throughput generation of hydrogel microbeads with varying elasticity for cell encapsulation. Biomaterials. 32 (6), 1477-1483 (2011).
  15. Fu, J., et al. Mechanical regulation of cell function with geometrically modulated elastomeric substrates. Nature Methods. 7 (9), 733-736 (2010).
  16. Pelham, R. J., Wang, Y. Cell locomotion and focal adhesions are regulated by substrate flexibility. Proc Natl Acad Sci U S A. 94 (25), 13661-13665 (1997).
  17. Tse, J. R., Engler, A. J., et al. Preparation of hydrogel substrates with tunable mechanical properties. Current protocols in cell biology / editorial board, Juan S. Bonifacino … [et al.]. 10 (Unit 10 16), (2010).
  18. Yeung, T., et al. Effects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion. Cell motility and the cytoskeleton. 60 (1), 24-34 (2005).
  19. Lo, C. -. M., Wang, H. -. B., Dembo, M., Wang, Y. -. l. Cell movement is guided by the rigidity of the substrate. Biophysical journal. 79 (1), 144-152 (2000).
  20. Engler, A. J., Sen, S., Sweeney, H. L., Discher, D. E. Matrix elasticity directs stem cell lineage specification. Cell. 126 (4), 677-689 (2006).
  21. Discher, D. E., Janmey, P., Wang, Y. -. l. Tissue cells feel and respond to the stiffness of their substrate. Science. 310 (5751), 1139-1143 (2005).
  22. Young, D. A., Choi, Y. S., Engler, A. J., Christman, K. L. Stimulation of adipogenesis of adult adipose-derived stem cells using substrates that mimic the stiffness of adipose tissue. Biomaterials. 34 (34), 8581-8588 (2013).
  23. Semler, E. J., Lancin, P. A., Dasgupta, A., Moghe, P. V. Engineering hepatocellular morphogenesis and function via ligand-presenting hydrogels with graded mechanical compliance. Biotechnology Bioengineering. 89 (3), 296-307 (2005).
  24. Reinhart-King, C. A., Dembo, M., Hammer, D. A. Cell-cell mechanical communication through compliant substrates. Biophysical journal. 95 (12), 6044-6051 (2008).
  25. Fischer, R. S., Myers, K. A., Gardel, M. L., Waterman, C. M. Stiffness-controlled three-dimensional extracellular matrices for high-resolution imaging of cell behavior. Nature protocols. 7 (11), 2056-2066 (2012).
  26. Quinlan, A. M., Billiar, K. L. Investigating the role of substrate stiffness in the persistence of valvular interstitial cell activation. Journal of Biomedical Materials Research Part A. 100 (9), 2474-2482 (2012).
  27. Zustiak, S. P., Leach, J. B. Hydrolytically degradable poly(ethylene glycol) hydrogel scaffolds with tunable degradation and mechanical properties. Biomacromolecules. 11 (5), 1348-1357 (2010).
  28. Chrambach, A., Rodbard, D. Polyacrylamide gel electrophoresis. Science. 172 (3982), 440-451 (1971).
  29. Lin, Y. C., et al. Mechanosensing of substrate thickness. Physical review. E, Statistical, nonlinear, and soft matter physics. 82 (4), 041918 (2010).
  30. Chrambach, A. . The Practice of Quantitative Gel Electrophoresis. , (1985).
  31. Sagvolden, G., Giaever, I., Pettersen, E. O., Feder, J. Cell adhesion force microscopy. Proceedings of the National Academy of Sciences of the United States of America. 96 (2), 471-476 (1999).
  32. Javaherian, S., Li, K. J., McGuigan, A. P. A simple and rapid method for generating patterned co-cultures with stable interfaces. BioTechniques. 55 (1), 21-26 (2013).
  33. Tarone, G., Galetto, G., Prat, M., Comoglio, P. M. Cell surface molecules and fibronectin-mediated cell adhesion: effect of proteolytic digestion of membrane proteins. The Journal of cell biology. 94 (1), 179-186 (1982).
  34. Trujillo, V., Kim, J., Hayward, R. C. Creasing instability of surface-attached hydrogels. Soft Matter. 4 (3), 564-569 (2008).
  35. Saha, K., et al. Surface creasing instability of soft polyacrylamide cell culture substrates. Biophysical journal. 99 (12), L94-L96 (2010).
  36. Buxboim, A., Rajagopal, K., Andre’EX, B., Discher, D. E. How deeply cells feel: methods for thin gels. Journal of Physics: Condensed Matter. 22 (19), 194116 (2010).
  37. Merkel, R., Kirchgessner, N., Cesa, C. M., Hoffmann, B. Cell force microscopy on elastic layers of finite thickness. Biophysical journal. 93 (9), 3314-3323 (2007).
check_url/es/52643?article_type=t

Play Video

Citar este artículo
Syed, S., Karadaghy, A., Zustiak, S. Simple Polyacrylamide-based Multiwell Stiffness Assay for the Study of Stiffness-dependent Cell Responses. J. Vis. Exp. (97), e52643, doi:10.3791/52643 (2015).

View Video