Summary

Semplice Poliacrilammide-based a più pozzetti Rigidità Assay per lo Studio della rigidezza-dipendenti le risposte delle cellule

Published: March 25, 2015
doi:

Summary

Here, a method that enables quick, efficient, and inexpensive preparation of polyacrylamide gels in a multiwell plate format is described. The method does not require any specialized equipment and could be easily adopted by any research laboratory. It would be particularly useful in research focused on understanding stiffness-dependent cell responses.

Abstract

Currently, most of the in vitro cell research is performed on rigid tissue culture polystyrene (~1 GPa), while most cells in the body are attached to a matrix that is elastic and much softer (0.1 – 100 kPa). Since such stiffness mismatch greatly affects cell responses, there is a strong interest in developing hydrogel materials that span a wide range of stiffness to serve as cell substrates. Polyacrylamide gels, which are inexpensive and cover the stiffness range of all soft tissues in the body, are the hydrogel of choice for many research groups. However, polyacrylamide gel preparation is lengthy, tedious, and only suitable for small batches. Here, we describe an assay which by utilizing a permanent flexible plastic film as a structural support for the gels, enables the preparation of polyacrylamide gels in a multiwell plate format. The technique is faster, more efficient, and less costly than current methods and permits the preparation of gels of custom sizes not otherwise available. As it doesn’t require any specialized equipment, the method could be easily adopted by any research laboratory and would be particularly useful in research focused on understanding stiffness-dependent cell responses.

Introduction

La maggior parte dei tessuti del corpo sono materiali viscoelastici morbidi con un modulo di Young che vanno da 0,1 kPa per cervello a 100 kPa per cartilagine morbida, ma, più de ricerca sulle cellule vitro è condotta su coltura tissutale polistirene (TCP), che ha un modulo di ~ 1 GPa . 1 Questa mancata corrispondenza rigidità influenza notevolmente il modo in cui le cellule rispondono al loro ambiente. Un crescente corpo di ricerca è quindi dedicata alla chiarire l'effetto del substrato rigidità sul destino di vari tipi cellulari, comprese le cellule staminali 2,3. 4 Come risultato, più idrogel sono stati sviluppati per aiutare nella comprensione della cella rigidità-dipendente biologia compresi poliacrilammide (PA), 5-7 polietilene glicole (PEG), 8,9 polidimetilsilossano (PDMS), 10 e alginato. 11 Mentre la prova che substrato rigidità ha un impatto sostanziale sul destino delle cellule è in crescita, la maggior parte degli studi sono condotti su scala ridotta con un piccolo numero di samples. Sistematiche, studi multidimensionali sull'effetto di substrato rigidità per una serie di tipi cellulari o condizioni ambientali sono rare. 12

Sono state sviluppate diverse tecnologie idrogel high-throughput promettenti, tra cui microarrays basati PEG, 13 dispositivi microfluidici per la produzione di microsfere di agarosio idrogel, 14 o micro e nano-aste in cui la rigidità è modulata dal diametro e altezza delle microrods. 15 Tuttavia , le tecnologie per preparare questi substrati sono sofisticati e disponibili per il numero limitato di laboratori. Gran parte della ricerca che coinvolge rigidità modulato le risposte delle cellule utilizza poliacrilammide (PA) gel che non sono solo poco costoso e semplice da implementare, ma mostrano anche una gamma fisiologicamente rilevanti di modulo di Young, vale a dire 0,3 -. 300 kPa 16-22 Tuttavia, i metodi esistenti per fabbricare PA gel per colture cellulari molto lavoro e, conseguentemente, di preparazioneared in piccoli lotti. Alcune delle difficoltà associate alla preparazione di gel PA come substrati cellulari derivano dal requisito che i gel devono essere preparati: 1) in assenza di ossigeno per permettere la completa polimerizzazione, 2) con una superficie piana e liscia per consentire cellulare uniforme attaccamento e diffusione, e 3) fissata in modo al fondo del piatto di coltura cellulare per prevenire galleggiante.

Diversi gruppi hanno tentato di produrre gel PA per colture cellulari in grandi lotti. Semler et al. Fogli spessi preparati dei gel PA che erano poi "tagliata" con un perforatore e posizionati in piastre da 96 pozzetti. 23 Tuttavia, questo metodo è limitato a gel rigide, cioè,> 1 kPa nel modulo di Young, perchè più morbido gel sono "sticky", difficile da tagliare, e facilmente danneggiati. Mih et al. Sviluppato una tecnica più sofisticata che permette i gel da polimerizzare direttamente in una piastra multipozzetto fondo di vetro. <sup> 6 Questo è stato ottenuto versando le soluzioni di gel in lastre di vetro-bottom funzionalizzate e formando gel da "sandwich" di loro con un allineamento coprioggetti personalizzato. 6 Anche se, lievi effetti di bordo molto promettenti sono stati ancora osservati con questa tecnica. Inoltre, la tecnica richiede una matrice custom-designed non immediatamente accessibili a molti laboratori e costose piastre a pozzetti multipli con fondo di vetro.

Questo documento descrive un modo semplice e poco costoso da montare gel PA in una piastra multipozzetto che potrebbe facilmente essere adottata da qualsiasi laboratorio. Qui, un supporto plastico flessibile è utilizzato, che ha due lati – uno idrofoba, che è repellente per gel PA, e uno idrofila, che si lega covalentemente il gel PA sulla deposizione. Una volta fogli di gel PA vengono depositati e permanentemente affissa al supporto plastico flessibile, consente la movimentazione gel di qualsiasi spessore o rigidità e taglio in qualsiasi forma desiderata. Questo approach non solo produce custom 'vetrini' di plastica in formati non altrimenti disponibili in commercio, ma evita anche la necessità di pre-trattare le superfici di vetro, sia vetrini o pozzetti di costose lastre di pozzetti con fondo di vetro, con una soluzione PA vincolante, che è un noioso e un passo che richiede tempo. Infine, uniformi fogli gel PA possono essere preparati in grandi lotti e de-idratato conservati per alcuni mesi.

In sintesi, il saggio qui presentato è un miglioramento rispetto ai metodi esistenti in diversi aspetti. In primo luogo, il processo di assemblaggio piastra multipozzetto è efficiente, e il costo complessivo dei materiali necessari è basso. In secondo luogo, gli idrogel sono prodotte in grandi lotti in un unico film gel omogeneo. Infine, solo materiali che sono commercialmente disponibili sono richiesti. L'utilità del saggio è illustrato esplorare l'effetto di substrato rigidità sulla morfologia cellulare e zona diffusione.

Protocol

1. Preparazione di soluzioni e Aliquote Hydrogel associati Preparazione della soluzione poliacrilammide gel precursore. Preparare soluzione di gel di poliacrilammide precursore miscelando acrilammide (A) (40% w / v, M r 71.08 g / mol), la bisacrylamide reticolante (B) (2% w / v, M r 154.17 g / mol), e de- acqua ionizzata nelle percentuali di volume specificati nella tabella 1. NOTA: Queste soluzioni possono essere preparati in grandi lotti e conservati a …

Representative Results

Poliacrilammide (PA) idrogel sono ampiamente usati per testare le risposte delle cellule rigidità-dipendente. 17,24 Miscelando varie concentrazioni di acrilammide (A) e bis-acrilamide (B) si possono fare gel PA che abbracciano la gamma di maggior rigidità tessuti molli in il corpo – 0,3 -.. 300 modulo di kPa giovane 1 Tuttavia, la preparazione di gel di poliacrilammide è noioso e che richiede tempo, spesso limitando la loro utilità in applicazioni "high throughput" come per lo screeni…

Discussion

Gel di poliacrilammide, originariamente sviluppati per elettroforesi, 28 sono oggi utilizzati di routine come substrati di coltura cellulare per studiare gli effetti di substrato rigidità sulla morfologia delle cellule, la motilità e la comunicazione 3,24,29 tra le altre caratteristiche cellulari. Poliacrilammide consente la manipolazione del substrato rigidità che comprende la rigidità di tutti i tessuti molli del corpo (0,3 – 300 kPa) 1 con una semplice variazione della concentrazi…

Divulgaciones

The authors have nothing to disclose.

Acknowledgements

This work was funded by start-up funds provided to Dr. Silviya Zustiak by Saint Louis University as well as by a President’s Research Fund (PRF) grant awarded to Dr. Silviya Zustiak by Saint Louis University. We thank Naveed Ahmed and Keval Shah for technical assistance.

Materials

Reagents
40% Acrylamide Bio-Rad 161-0140
2% Bis-acrylamide Bio-Rad 161-0142
Ammonium Persulfate Bio-Rad 161-07000
TEMED Sigma Aldrich T9281
Sulfo-SANPAH Thermo Scientific 22589
Collagen Type 1, from Rat tail, 3.68 mg/mL BD Biosciences 354236
Dimethyl sulfoxide (DMSO) Fisher Scientific  BP231-100
Hydrophobic solution – Repel Silane  GE Healthcare Bio-Sciences 17-1332-01
PBS (1x), pH 7.4 HyClone SH30256.01
Polydimehylsiloxane (PDMS) [Slygard 182 Elastomer Kit] Elsworth Adhesives 3097358-1004
Tyrpsin/EDTA (10x) Sigma Aldrich 44174
RPMI-1640 Medium (1x) HyClone SH30027-02
Fetal Bovine Serum HyClone SH30073-03
Penicillin Streptomycin MP Biomedicals 1670046
Detergent – Triton-X Sigma Aldrich T8787
Formaldehyde 37% Solution Sigma Aldrich F1635
Bovine Serum Albumin (BSA) Sigma Aldrich A2153
BSA-based cell adhesion blocking kit – ECM Cell Adhesion Array Kit Chemicon International ECM540
Disposable lab equipment
flexible plastic support – GelBond PAG Film for Polyacrylamide Gels GE Healthcare Bio-Sciences 309819
Glass Plates Slumpys GBS4100SFSL
50 mL Conicals Fisher Scinetific 3181345107
15 mL Conicals FALCON 352097
Micro centrifuge tubes Fisher Scinetific 2 mL: 02681258
96-well plate (flat bottom) Fisher Scinetific 12565501
Disposable Pipettes (1 mL, 2mL, 5mL, 10mL, 25 mL, 50mL) Fisher Scinetific 1 mL: 13-678-11B, 2mL: 05214038, 5mL(FALCON): 357529, 10mL: 13-678-11E, 25mL: 13-678-11, 50mL: 13-678-11F
Glass Transfer Pipettes Fisher Scinetific 5 3/4": 1367820A, 9":136786B
Pipette Tips (1-200uL, 101-1000uL) Fisher Scinetific 2707509
Plastic Standard Disposable Transfer Pipettes Fisher Scientific 13-711-9D
Parafilm PARAFILM  PM992
Powder Free Examination Gloves Quest 92897
Silicone spacers – Silicone sheet, 0.5 mm thick/13 cm x 18 cm Grace Bio-Labs JTR-S-0.5
Large/non-disposable lab equipment
Light and Flourescent Microscope (Axiovert 200M) Zeiss 3820005619
Microscope Software Zeiss AxioVision Rel. 4.8.2
UV oven UVITRON UV1080
Vacuum chamber/degasser BelArt 999320237
Vacuum pump for degasser KNF Lab 5097482
Tissue Culture Hood NUAIRE NU-425-600
Chemical Fume Hood KEWAUNEE 99151
Inverted Microscope (Axiovert 25) Zeiss 663526
Incubator NUAIRE NU-8500
Pipette Aid Drummond Scientific Co. P-76864
Hemacytometer Bright-Line 383684

Referencias

  1. Levental, I., Georges, P. C., Janmey, P. A. Soft biological materials and their impact on cell function. Soft Matter. 3, 299-306 (2007).
  2. Minton, K. Mechanotransduction: A stiff response. Nature Reviews Molecular Cell Biology. 15 (8), 500-500 (2014).
  3. Yeung, T., et al. Effects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion. Cell motility and the cytoskeleton. 60 (1), 24-34 (2005).
  4. Watt, F. M., Huck, W. T. Role of the extracellular matrix in regulating stem cell fate. Nature Reviews Molecular Cell Biology. 14 (8), 467-473 (2013).
  5. Zustiak, S., Nossal, R., Sackett, D. L. Multiwell stiffness assay for the study of cell responsiveness to cytotoxic drugs. Biotechnology and bioengineering. 111 (2), (2014).
  6. Mih, J. D., et al. A multiwell platform for studying stiffness-dependent cell biology. PLoS One. 6 (5), e19929 (2011).
  7. Sunyer, R., Jin, A. J., Nossal, R., Sackett, D. L. Fabrication of hydrogels with steep stiffness gradients for studying cell mechanical response. PloS one. 7 (10), e46107 (2012).
  8. Herrick, W. G., et al. PEG-phosphorylcholine hydrogels as tunable and versatile platforms for mechanobiology. Biomacromolecules. 14 (7), 2294-2304 (2013).
  9. Tokuda, E. Y., Leight, J. L., Anseth, K. S. Modulation of matrix elasticity with PEG hydrogels to study melanoma drug responsiveness. Biomaterials. 35 (14), 4310-4318 (2014).
  10. Feng, J., et al. Substrate stiffness influences the outcome of antitumor drug screening in vitro. Clinical hemorheology and microcirculation. 55 (1), 121-131 (2013).
  11. Ramamoorthi, K., Hara, J., Ito, C., Asuri, P. Role of Three-Dimensional Matrix Stiffness in Regulating the Response of Human Neural Cells to Toxins. Cellular and Molecular Bioengineering. 7 (2), 1-7 (2014).
  12. Tilghman, R. W., et al. Matrix rigidity regulates cancer cell growth and cellular phenotype. PloS one. 5 (9), e12905 (2010).
  13. Gobaa, S., et al. Artificial niche microarrays for probing single stem cell fate in high throughput. Nature methods. 8 (11), 949-955 (2011).
  14. Kumachev, A., et al. High-throughput generation of hydrogel microbeads with varying elasticity for cell encapsulation. Biomaterials. 32 (6), 1477-1483 (2011).
  15. Fu, J., et al. Mechanical regulation of cell function with geometrically modulated elastomeric substrates. Nature Methods. 7 (9), 733-736 (2010).
  16. Pelham, R. J., Wang, Y. Cell locomotion and focal adhesions are regulated by substrate flexibility. Proc Natl Acad Sci U S A. 94 (25), 13661-13665 (1997).
  17. Tse, J. R., Engler, A. J., et al. Preparation of hydrogel substrates with tunable mechanical properties. Current protocols in cell biology / editorial board, Juan S. Bonifacino … [et al.]. 10 (Unit 10 16), (2010).
  18. Yeung, T., et al. Effects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion. Cell motility and the cytoskeleton. 60 (1), 24-34 (2005).
  19. Lo, C. -. M., Wang, H. -. B., Dembo, M., Wang, Y. -. l. Cell movement is guided by the rigidity of the substrate. Biophysical journal. 79 (1), 144-152 (2000).
  20. Engler, A. J., Sen, S., Sweeney, H. L., Discher, D. E. Matrix elasticity directs stem cell lineage specification. Cell. 126 (4), 677-689 (2006).
  21. Discher, D. E., Janmey, P., Wang, Y. -. l. Tissue cells feel and respond to the stiffness of their substrate. Science. 310 (5751), 1139-1143 (2005).
  22. Young, D. A., Choi, Y. S., Engler, A. J., Christman, K. L. Stimulation of adipogenesis of adult adipose-derived stem cells using substrates that mimic the stiffness of adipose tissue. Biomaterials. 34 (34), 8581-8588 (2013).
  23. Semler, E. J., Lancin, P. A., Dasgupta, A., Moghe, P. V. Engineering hepatocellular morphogenesis and function via ligand-presenting hydrogels with graded mechanical compliance. Biotechnology Bioengineering. 89 (3), 296-307 (2005).
  24. Reinhart-King, C. A., Dembo, M., Hammer, D. A. Cell-cell mechanical communication through compliant substrates. Biophysical journal. 95 (12), 6044-6051 (2008).
  25. Fischer, R. S., Myers, K. A., Gardel, M. L., Waterman, C. M. Stiffness-controlled three-dimensional extracellular matrices for high-resolution imaging of cell behavior. Nature protocols. 7 (11), 2056-2066 (2012).
  26. Quinlan, A. M., Billiar, K. L. Investigating the role of substrate stiffness in the persistence of valvular interstitial cell activation. Journal of Biomedical Materials Research Part A. 100 (9), 2474-2482 (2012).
  27. Zustiak, S. P., Leach, J. B. Hydrolytically degradable poly(ethylene glycol) hydrogel scaffolds with tunable degradation and mechanical properties. Biomacromolecules. 11 (5), 1348-1357 (2010).
  28. Chrambach, A., Rodbard, D. Polyacrylamide gel electrophoresis. Science. 172 (3982), 440-451 (1971).
  29. Lin, Y. C., et al. Mechanosensing of substrate thickness. Physical review. E, Statistical, nonlinear, and soft matter physics. 82 (4), 041918 (2010).
  30. Chrambach, A. . The Practice of Quantitative Gel Electrophoresis. , (1985).
  31. Sagvolden, G., Giaever, I., Pettersen, E. O., Feder, J. Cell adhesion force microscopy. Proceedings of the National Academy of Sciences of the United States of America. 96 (2), 471-476 (1999).
  32. Javaherian, S., Li, K. J., McGuigan, A. P. A simple and rapid method for generating patterned co-cultures with stable interfaces. BioTechniques. 55 (1), 21-26 (2013).
  33. Tarone, G., Galetto, G., Prat, M., Comoglio, P. M. Cell surface molecules and fibronectin-mediated cell adhesion: effect of proteolytic digestion of membrane proteins. The Journal of cell biology. 94 (1), 179-186 (1982).
  34. Trujillo, V., Kim, J., Hayward, R. C. Creasing instability of surface-attached hydrogels. Soft Matter. 4 (3), 564-569 (2008).
  35. Saha, K., et al. Surface creasing instability of soft polyacrylamide cell culture substrates. Biophysical journal. 99 (12), L94-L96 (2010).
  36. Buxboim, A., Rajagopal, K., Andre’EX, B., Discher, D. E. How deeply cells feel: methods for thin gels. Journal of Physics: Condensed Matter. 22 (19), 194116 (2010).
  37. Merkel, R., Kirchgessner, N., Cesa, C. M., Hoffmann, B. Cell force microscopy on elastic layers of finite thickness. Biophysical journal. 93 (9), 3314-3323 (2007).
check_url/es/52643?article_type=t

Play Video

Citar este artículo
Syed, S., Karadaghy, A., Zustiak, S. Simple Polyacrylamide-based Multiwell Stiffness Assay for the Study of Stiffness-dependent Cell Responses. J. Vis. Exp. (97), e52643, doi:10.3791/52643 (2015).

View Video