Summary

Multiwell Rigidez Ensayo para el Estudio de las respuestas de las células Rigidez dependientes simple basado poliacrilamida-

Published: March 25, 2015
doi:

Summary

Here, a method that enables quick, efficient, and inexpensive preparation of polyacrylamide gels in a multiwell plate format is described. The method does not require any specialized equipment and could be easily adopted by any research laboratory. It would be particularly useful in research focused on understanding stiffness-dependent cell responses.

Abstract

Currently, most of the in vitro cell research is performed on rigid tissue culture polystyrene (~1 GPa), while most cells in the body are attached to a matrix that is elastic and much softer (0.1 – 100 kPa). Since such stiffness mismatch greatly affects cell responses, there is a strong interest in developing hydrogel materials that span a wide range of stiffness to serve as cell substrates. Polyacrylamide gels, which are inexpensive and cover the stiffness range of all soft tissues in the body, are the hydrogel of choice for many research groups. However, polyacrylamide gel preparation is lengthy, tedious, and only suitable for small batches. Here, we describe an assay which by utilizing a permanent flexible plastic film as a structural support for the gels, enables the preparation of polyacrylamide gels in a multiwell plate format. The technique is faster, more efficient, and less costly than current methods and permits the preparation of gels of custom sizes not otherwise available. As it doesn’t require any specialized equipment, the method could be easily adopted by any research laboratory and would be particularly useful in research focused on understanding stiffness-dependent cell responses.

Introduction

La mayoría de los tejidos en el cuerpo son materiales viscoelásticos suaves con un módulo de Young que varía de 0,1 kPa para el cerebro a 100 kPa para el cartílago suave, sin embargo, la mayoría es la investigación de células in vitro se lleva a cabo en poliestireno de cultivo de tejido (TCP), que tiene un módulo de ~ 1 GPa . 1 Este desajuste rigidez afecta en gran medida la forma en las células responden a su medio ambiente. Un cuerpo creciente de investigación es, pues, dedicada a elucidar el efecto de la rigidez del sustrato sobre el destino de diversos tipos de células, incluidas las células madre 2,3. 4 Como resultado, múltiples hidrogeles han sido desarrollados para ayudar en la comprensión de la célula de rigidez dependiente biología incluyendo poliacrilamida (PA), 5-7 polietilenglicol (PEG), 8,9 polidimetilsiloxano (PDMS), 10 y alginato. 11 Mientras que la evidencia de que la rigidez del sustrato tiene un impacto sustancial en el destino celular está creciendo, se llevan a cabo en la mayoría de los estudios una pequeña escala con un pequeño número de sejemplos. Los estudios sistemáticos, multidimensionales sobre el efecto de la rigidez del sustrato para una gran variedad de tipos de células o las condiciones ambientales son raros. 12

Varias tecnologías de hidrogel de alto rendimiento prometedores se han desarrollado, incluyendo microarrays basados ​​en PEG, 13 dispositivos de microfluidos para la producción de microperlas de agarosa de hidrogel, 14 o micro y nano-barras, donde la rigidez es modulada por el diámetro y la altura de los los micro. 15 Sin embargo , las tecnologías de la preparación de dichos sustratos son sofisticados y disponible para un número limitado de laboratorios. Mucha investigación que implica rigidez modulada respuestas de células utiliza poliacrilamida (PA) geles que no sólo son de bajo costo y simple de implementar, sino también exhibir una gama fisiológicamente relevante del módulo de Young, es decir, 0,3 -. 300 kPa 16-22 Sin embargo, los métodos existentes para fabricar PA geles para el cultivo celular son mano de obra intensiva y, en consecuencia prepared en pequeños lotes. Algunas de las dificultades asociadas con la preparación de geles PA como sustratos de células madre a partir de la exigencia de que los geles tienen que estar preparados: 1) en ausencia de oxígeno para permitir la polimerización completa, 2) con una superficie plana y lisa para permitir celular uniforme apego y difusión, y 3) fijado de forma permanente a la parte inferior de la placa de cultivo celular para prevenir flotante.

Varios grupos han intentado producir geles PA para el cultivo de células en grandes lotes. Semler et al. Láminas gruesas preparados de geles PA que fueron luego "cortada" con un punzón y se colocaron en placas de 96 pocillos. 23 Sin embargo, este método está limitado a geles más rígidos, es decir,> 1 kPa en el módulo de Young, ya que más suave geles son "pegajosos", difícil de cortar, y se dañan fácilmente. Mih et al. Desarrolló una técnica más sofisticada que permite a los geles a polimerizar directamente en una placa de múltiples pocillos con fondo de cristal. <sarriba> 6 Esto se logró mediante el vertido de las soluciones de gel en placas con fondo de vidrio funcionalizadas y formar geles por "sandwich" con una matriz cubreobjetos personalizado. 6 A pesar de que, los efectos de borde ligeras muy prometedores todavía se observaron con esta técnica. Además, la técnica requiere una matriz de diseño personalizado no inmediatamente accesible a muchos laboratorios, así como costosas placas de múltiples pocillos con fondo de cristal.

Este documento describe una manera sencilla y económica de montar geles PA en una placa de múltiples pocillos que podría ser adoptado fácilmente por cualquier laboratorio. Aquí, se utiliza un soporte de plástico flexible, que tiene dos lados – un uno hidrofóbico, que es repelente a los geles PA, y uno hidrofílico, que se une covalentemente el gel de PA sobre la deposición. Una vez láminas de gel de PA se depositan y permanentemente fijada en el soporte de plástico flexible, permite un manejo geles de cualquier grosor o rigidez y cortarlos en cualquier forma deseada. Este aproach no sólo produce personalizados '' cubreobjetos de plástico en tamaños no disponibles comercialmente, sino que también elimina la necesidad de las superficies de vidrio-tratamiento previo, ya sea cubreobjetos de vidrio o los pozos de las costosas placas de múltiples pocillos con fondo de cristal, con una solución PA vinculante, que es un tedioso y un paso de tiempo. Por último, las hojas de geles PA uniformes se pueden preparar en grandes lotes y se almacenaron-de hidratado durante varios meses.

En resumen, el ensayo que aquí se presenta es una mejora sobre los métodos existentes en varios aspectos. En primer lugar, el proceso de montaje de placa de pocillos múltiples, es eficiente, y el coste global de los materiales requeridos es baja. En segundo lugar, los hidrogeles se producen en grandes lotes en una única película de gel homogénea. Finalmente, sólo se requieren materiales que están disponibles comercialmente. La utilidad del ensayo se ilustra por explorar el efecto de la rigidez del sustrato sobre la morfología celular y el área de difusión.

Protocol

1. Preparación de soluciones y alícuotas asociados hidrogel Preparación de la solución de poliacrilamida precursor del gel. Preparar la solución de precursor de gel de poliacrilamida mediante la mezcla de acrilamida (A) (40% w / v, r M 71,08 g / mol), el bisacrilamida reticulante (B) (2% w / v, r M 154,17 g / mol), y de- agua ionizada en los porcentajes en volumen especificados en la Tabla 1. NOTA: Estas soluciones se pueden preparar en grandes lotes…

Representative Results

Poliacrilamida (PA) hidrogeles son ampliamente utilizados para probar las respuestas de células de rigidez dependiente. 17,24 Mediante la mezcla de varias concentraciones de acrilamida (A) y bis-acrilamida (B) se puede hacer geles de PA que abarcan el rango de rigidez de la mayoría de los tejidos blandos en el cuerpo – 0,3 -.. 300 módulo de kPa joven 1 Sin embargo, la preparación de geles de poliacrilamida es tedioso y consume mucho tiempo, a menudo limita su utilidad en aplicaciones de "a…

Discussion

Geles de poliacrilamida, desarrollados originalmente para la electroforesis, 28 ahora se utilizan rutinariamente como sustratos de cultivo celular para estudiar los efectos de la rigidez del sustrato sobre la morfología celular, la motilidad y la comunicación 3,24,29 entre otras características de las células. Poliacrilamida permite la manipulación de la rigidez del sustrato para abarcar la rigidez de los tejidos blandos del cuerpo (0,3 a 300 kPa) 1 con un simple cambio en la concen…

Divulgaciones

The authors have nothing to disclose.

Acknowledgements

This work was funded by start-up funds provided to Dr. Silviya Zustiak by Saint Louis University as well as by a President’s Research Fund (PRF) grant awarded to Dr. Silviya Zustiak by Saint Louis University. We thank Naveed Ahmed and Keval Shah for technical assistance.

Materials

Reagents
40% Acrylamide Bio-Rad 161-0140
2% Bis-acrylamide Bio-Rad 161-0142
Ammonium Persulfate Bio-Rad 161-07000
TEMED Sigma Aldrich T9281
Sulfo-SANPAH Thermo Scientific 22589
Collagen Type 1, from Rat tail, 3.68 mg/mL BD Biosciences 354236
Dimethyl sulfoxide (DMSO) Fisher Scientific  BP231-100
Hydrophobic solution – Repel Silane  GE Healthcare Bio-Sciences 17-1332-01
PBS (1x), pH 7.4 HyClone SH30256.01
Polydimehylsiloxane (PDMS) [Slygard 182 Elastomer Kit] Elsworth Adhesives 3097358-1004
Tyrpsin/EDTA (10x) Sigma Aldrich 44174
RPMI-1640 Medium (1x) HyClone SH30027-02
Fetal Bovine Serum HyClone SH30073-03
Penicillin Streptomycin MP Biomedicals 1670046
Detergent – Triton-X Sigma Aldrich T8787
Formaldehyde 37% Solution Sigma Aldrich F1635
Bovine Serum Albumin (BSA) Sigma Aldrich A2153
BSA-based cell adhesion blocking kit – ECM Cell Adhesion Array Kit Chemicon International ECM540
Disposable lab equipment
flexible plastic support – GelBond PAG Film for Polyacrylamide Gels GE Healthcare Bio-Sciences 309819
Glass Plates Slumpys GBS4100SFSL
50 mL Conicals Fisher Scinetific 3181345107
15 mL Conicals FALCON 352097
Micro centrifuge tubes Fisher Scinetific 2 mL: 02681258
96-well plate (flat bottom) Fisher Scinetific 12565501
Disposable Pipettes (1 mL, 2mL, 5mL, 10mL, 25 mL, 50mL) Fisher Scinetific 1 mL: 13-678-11B, 2mL: 05214038, 5mL(FALCON): 357529, 10mL: 13-678-11E, 25mL: 13-678-11, 50mL: 13-678-11F
Glass Transfer Pipettes Fisher Scinetific 5 3/4": 1367820A, 9":136786B
Pipette Tips (1-200uL, 101-1000uL) Fisher Scinetific 2707509
Plastic Standard Disposable Transfer Pipettes Fisher Scientific 13-711-9D
Parafilm PARAFILM  PM992
Powder Free Examination Gloves Quest 92897
Silicone spacers – Silicone sheet, 0.5 mm thick/13 cm x 18 cm Grace Bio-Labs JTR-S-0.5
Large/non-disposable lab equipment
Light and Flourescent Microscope (Axiovert 200M) Zeiss 3820005619
Microscope Software Zeiss AxioVision Rel. 4.8.2
UV oven UVITRON UV1080
Vacuum chamber/degasser BelArt 999320237
Vacuum pump for degasser KNF Lab 5097482
Tissue Culture Hood NUAIRE NU-425-600
Chemical Fume Hood KEWAUNEE 99151
Inverted Microscope (Axiovert 25) Zeiss 663526
Incubator NUAIRE NU-8500
Pipette Aid Drummond Scientific Co. P-76864
Hemacytometer Bright-Line 383684

Referencias

  1. Levental, I., Georges, P. C., Janmey, P. A. Soft biological materials and their impact on cell function. Soft Matter. 3, 299-306 (2007).
  2. Minton, K. Mechanotransduction: A stiff response. Nature Reviews Molecular Cell Biology. 15 (8), 500-500 (2014).
  3. Yeung, T., et al. Effects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion. Cell motility and the cytoskeleton. 60 (1), 24-34 (2005).
  4. Watt, F. M., Huck, W. T. Role of the extracellular matrix in regulating stem cell fate. Nature Reviews Molecular Cell Biology. 14 (8), 467-473 (2013).
  5. Zustiak, S., Nossal, R., Sackett, D. L. Multiwell stiffness assay for the study of cell responsiveness to cytotoxic drugs. Biotechnology and bioengineering. 111 (2), (2014).
  6. Mih, J. D., et al. A multiwell platform for studying stiffness-dependent cell biology. PLoS One. 6 (5), e19929 (2011).
  7. Sunyer, R., Jin, A. J., Nossal, R., Sackett, D. L. Fabrication of hydrogels with steep stiffness gradients for studying cell mechanical response. PloS one. 7 (10), e46107 (2012).
  8. Herrick, W. G., et al. PEG-phosphorylcholine hydrogels as tunable and versatile platforms for mechanobiology. Biomacromolecules. 14 (7), 2294-2304 (2013).
  9. Tokuda, E. Y., Leight, J. L., Anseth, K. S. Modulation of matrix elasticity with PEG hydrogels to study melanoma drug responsiveness. Biomaterials. 35 (14), 4310-4318 (2014).
  10. Feng, J., et al. Substrate stiffness influences the outcome of antitumor drug screening in vitro. Clinical hemorheology and microcirculation. 55 (1), 121-131 (2013).
  11. Ramamoorthi, K., Hara, J., Ito, C., Asuri, P. Role of Three-Dimensional Matrix Stiffness in Regulating the Response of Human Neural Cells to Toxins. Cellular and Molecular Bioengineering. 7 (2), 1-7 (2014).
  12. Tilghman, R. W., et al. Matrix rigidity regulates cancer cell growth and cellular phenotype. PloS one. 5 (9), e12905 (2010).
  13. Gobaa, S., et al. Artificial niche microarrays for probing single stem cell fate in high throughput. Nature methods. 8 (11), 949-955 (2011).
  14. Kumachev, A., et al. High-throughput generation of hydrogel microbeads with varying elasticity for cell encapsulation. Biomaterials. 32 (6), 1477-1483 (2011).
  15. Fu, J., et al. Mechanical regulation of cell function with geometrically modulated elastomeric substrates. Nature Methods. 7 (9), 733-736 (2010).
  16. Pelham, R. J., Wang, Y. Cell locomotion and focal adhesions are regulated by substrate flexibility. Proc Natl Acad Sci U S A. 94 (25), 13661-13665 (1997).
  17. Tse, J. R., Engler, A. J., et al. Preparation of hydrogel substrates with tunable mechanical properties. Current protocols in cell biology / editorial board, Juan S. Bonifacino … [et al.]. 10 (Unit 10 16), (2010).
  18. Yeung, T., et al. Effects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion. Cell motility and the cytoskeleton. 60 (1), 24-34 (2005).
  19. Lo, C. -. M., Wang, H. -. B., Dembo, M., Wang, Y. -. l. Cell movement is guided by the rigidity of the substrate. Biophysical journal. 79 (1), 144-152 (2000).
  20. Engler, A. J., Sen, S., Sweeney, H. L., Discher, D. E. Matrix elasticity directs stem cell lineage specification. Cell. 126 (4), 677-689 (2006).
  21. Discher, D. E., Janmey, P., Wang, Y. -. l. Tissue cells feel and respond to the stiffness of their substrate. Science. 310 (5751), 1139-1143 (2005).
  22. Young, D. A., Choi, Y. S., Engler, A. J., Christman, K. L. Stimulation of adipogenesis of adult adipose-derived stem cells using substrates that mimic the stiffness of adipose tissue. Biomaterials. 34 (34), 8581-8588 (2013).
  23. Semler, E. J., Lancin, P. A., Dasgupta, A., Moghe, P. V. Engineering hepatocellular morphogenesis and function via ligand-presenting hydrogels with graded mechanical compliance. Biotechnology Bioengineering. 89 (3), 296-307 (2005).
  24. Reinhart-King, C. A., Dembo, M., Hammer, D. A. Cell-cell mechanical communication through compliant substrates. Biophysical journal. 95 (12), 6044-6051 (2008).
  25. Fischer, R. S., Myers, K. A., Gardel, M. L., Waterman, C. M. Stiffness-controlled three-dimensional extracellular matrices for high-resolution imaging of cell behavior. Nature protocols. 7 (11), 2056-2066 (2012).
  26. Quinlan, A. M., Billiar, K. L. Investigating the role of substrate stiffness in the persistence of valvular interstitial cell activation. Journal of Biomedical Materials Research Part A. 100 (9), 2474-2482 (2012).
  27. Zustiak, S. P., Leach, J. B. Hydrolytically degradable poly(ethylene glycol) hydrogel scaffolds with tunable degradation and mechanical properties. Biomacromolecules. 11 (5), 1348-1357 (2010).
  28. Chrambach, A., Rodbard, D. Polyacrylamide gel electrophoresis. Science. 172 (3982), 440-451 (1971).
  29. Lin, Y. C., et al. Mechanosensing of substrate thickness. Physical review. E, Statistical, nonlinear, and soft matter physics. 82 (4), 041918 (2010).
  30. Chrambach, A. . The Practice of Quantitative Gel Electrophoresis. , (1985).
  31. Sagvolden, G., Giaever, I., Pettersen, E. O., Feder, J. Cell adhesion force microscopy. Proceedings of the National Academy of Sciences of the United States of America. 96 (2), 471-476 (1999).
  32. Javaherian, S., Li, K. J., McGuigan, A. P. A simple and rapid method for generating patterned co-cultures with stable interfaces. BioTechniques. 55 (1), 21-26 (2013).
  33. Tarone, G., Galetto, G., Prat, M., Comoglio, P. M. Cell surface molecules and fibronectin-mediated cell adhesion: effect of proteolytic digestion of membrane proteins. The Journal of cell biology. 94 (1), 179-186 (1982).
  34. Trujillo, V., Kim, J., Hayward, R. C. Creasing instability of surface-attached hydrogels. Soft Matter. 4 (3), 564-569 (2008).
  35. Saha, K., et al. Surface creasing instability of soft polyacrylamide cell culture substrates. Biophysical journal. 99 (12), L94-L96 (2010).
  36. Buxboim, A., Rajagopal, K., Andre’EX, B., Discher, D. E. How deeply cells feel: methods for thin gels. Journal of Physics: Condensed Matter. 22 (19), 194116 (2010).
  37. Merkel, R., Kirchgessner, N., Cesa, C. M., Hoffmann, B. Cell force microscopy on elastic layers of finite thickness. Biophysical journal. 93 (9), 3314-3323 (2007).
check_url/es/52643?article_type=t

Play Video

Citar este artículo
Syed, S., Karadaghy, A., Zustiak, S. Simple Polyacrylamide-based Multiwell Stiffness Assay for the Study of Stiffness-dependent Cell Responses. J. Vis. Exp. (97), e52643, doi:10.3791/52643 (2015).

View Video