Summary

Damlacık Mikroakiskan için renkli Floresan Algılama Optik Elyaf kullanma

Published: May 05, 2016
doi:

Summary

Multicolor fluorescence detection in droplet microfluidics typically involves bulky and complex epifluorescence microscope-based detection systems. Here we describe a compact and modular multicolor detection scheme that utilizes an array of optical fibers to temporally encode multicolor data collected by a single photodetector.

Abstract

Fluorescence assays are the most common readouts used in droplet microfluidics due to their bright signals and fast time response. Applications such as multiplex assays, enzyme evolution, and molecular biology enhanced cell sorting require the detection of two or more colors of fluorescence. Standard multicolor detection systems that couple free space lasers to epifluorescence microscopes are bulky, expensive, and difficult to maintain. In this paper, we describe a scheme to perform multicolor detection by exciting discrete regions of a microfluidic channel with lasers coupled to optical fibers. Emitted light is collected by an optical fiber coupled to a single photodetector. Because the excitation occurs at different spatial locations, the identity of emitted light can be encoded as a temporal shift, eliminating the need for more complicated light filtering schemes. The system has been used to detect droplet populations containing four unique combinations of dyes and to detect sub-nanomolar concentrations of fluorescein.

Introduction

Damlacık Mikroakiskan bir taşıyıcı yağ 1 içinde süspansiyon haline sulu damlacıkların çok sayıda deney bölümlere yüksek verimli biyoloji için bir platform sağlar. Damlacıklar tek bir hücre analizi 2, dijital polimeraz zincir reaksiyonu (PCR) 3 gibi çeşitli uygulamalarda kullanılan ve evrim 4 enzim edilmiştir. Parlak sinyaller ve hızlı zaman yanıtı kilohertz oranlarında alt nanoliter damlacık hacimleri tespit uyumlu olarak Floresan tahlilleri, damlacık Mikroakiskan için algılama standart modu bulunmaktadır. Birçok uygulama, aynı anda en az iki renk için floresans algılama gerektirir. Örneğin, bizim laboratuar yaygın bir tahlil sonucu için bir algılama kanalı kullanmak damlacık sıralama deneyleri PCR aktive gerçekleştirir ve 5 tahlil negatif damlacık sayılabilir yapmak için ikincil bir arka plan boya kullanır.

damlacık Mikroakiskan için tipik algılama istasyonları ba vardırEpifloresans mikroskoplar üzerinde sed ve numune odaklı olmak mikroskop içine boş alan lazerler uyarma ışık tanıtmak için ışık manipülasyonlar düzenleri karmaşık gerektirir. floresan bir damlacık yayılan sonra her algılama kanalı dalgaboyu bandında merkezli bir photomultiplier tüp (PMT) kullanır, böylece yayılan fluoresced ışık süzülür. Epifloresans mikroskop tabanlı optik algılama sistemleri nedeniyle gider, karmaşıklık girişine bir bariyer sağlar ve bakım gereklidir. Optik fiberler fiberler elle ayna tabanlı ışık yönlendirme ihtiyacını ortadan kaldırarak, ve ışık yolları fiber optik konnektörleri kullanarak arabirim sağlayan mikroakışkan cihazlar eklenebilir çünkü araçlar, basitleştirilmiş ve sağlam algılama düzeni inşa etmek sağlarlar.

Bu yazıda, optik fiberler An bir dizi kullanarak çok renkli floresan algılama gerçekleştirmek için kompakt ve modüler bir düzeni montaj ve doğrulama tarifda tek fotodetektör 6. Optik fiberler bağımsız lazer bağlanır ve düzenli mekansal uzaklıklar bir L şeklinde bir akış kanalına dik yerleştirilir. Bir flüoresan toplama fiber uyarım bölgelerine paralel yönlendirilmiş olan ve tek bir PMT bağlanır. Bir damlacık farklı zamanlarda lazer ışınları geçer, çünkü PMT tarafından kaydedilen veriler zamansal kullanıcı damlacık her ayrı lazer ışını tarafından heyecan sonra yayılan floresan ayırt sağlar ofset gösterir. Bu zamansal kayma dikroik aynalar ve bant geçiren filtreler bir dizi kullanarak ayrı Proje Yönetim Ekipleri yayılan ışık ayırmak için gereksinimini ortadan kaldırır. Dedektörün etkinliğini doğrulamak için, biz farklı renk ve konsantrasyon boyalar encapsulating damlacık popülasyonlarında floresan ölçmek. sistemin duyarlılığı tek renkli floresan saptama için incelenmiş, ve 0.1 nM bir 200x hassasiyet göstr kadar konsantrasyonlarda damlacıklar tespit edilebildiğini gösterirLiteratürde 7 bildirilen son elyaf bazlı yaklaşımlar karşılaştırıldığında ovement.

Protocol

1. SU8 Ana Fabrikasyon tasarım yazılımı kullanarak üç katmanlı imalat için mikroakışkan yapıları tasarlamak ve 10 mikron çözünürlükte devre kartı film üzerine bir satıcı tarafından basılan tasarımları var. Cihaz tasarımı detayları ekli referans 6'da verilmiştir ve kanal geometrileri, Şekil 1 'de gösterilmiştir. Katmanlar, her imalat tabaka 8'den özellikleri yan yana koymak yardımcı hizalama işaretleri içermelidir. <li…

Representative Results

Optik fiberlerin yerleştirilmesi için izin veren bir PDMS cihazın imalatı değişen yükseklik (Şekil 1) kanalları oluşturmak için çok adımlı bir fotolitografi prosedürü gerektirir. İlk olarak, SU-8 80 um boyunda tabaka silikon yonga üzerine bükülmüş ve akışkan geometrisini oluşturmak için bir maske kullanılarak şekillendirilmiştir. Sonraki, SU-8 ek 40 mikron katman gofret üzerine bükülmüş ve 120 mikron boyunda lazer fiber ekleme kanalları…

Discussion

Fiber optik algılama akışkan kanal ile ilgili olarak, optik fiberlerin hizalanmasını gerektirir. Bizim cihaz çok tabakalı fotolitografiyle imal kılavuz kanalları kullandığından, birbirlerine göre olan maske yerleştirilmesi büyük önem taşımaktadır. Fiber kılavuz kanallar sıvı kanala çok yakın ise, sıvı sızması için bir potansiyel var; kılavuz kanallar çok uzakta bulunan ya da hizadan ise, algılama fiber tarafından toplanan floresan sinyali önemli ölçüde azalabilir. Tam hizalama foto?…

Divulgaciones

The authors have nothing to disclose.

Acknowledgements

This work was supported by DARPA grant number 84389.01.44908, an NSF CAREER award (DBI-1253293), an NIH exploratory/developmental research grant (CA195709), and NIH New Innovator Awards (HD080351, DP2-AR068129-01), and a New Directions grant from the UCSF resource allocation program.

Materials

Photomasks CadArt Servcies
3" silicon wafers, P type, virgin test grade University Wafers 447
SU-8 3035 Microchem Y311074
SU-8 2050 Microchem Y111072
Sylgard 184 silicone elastomer kit Krayden 4019862
1 ml syringes BD 309628
10 ml syringes BD 309604
27 gaugue needles BD 305109
PE 2 polyethylene tubing Scientific Commodities, Inc. B31695-PE/2
Novec 7500 Fisher Scientific 98-0212-2928-5 Commonly knowns as HFE 7500
Ionic Krytox Surfactant Synthesis instructions in ref #10
Dextran- conjugated cascade blue dye Life Technologies D-1976
Fluorescein sodium salt Sigma 28803
Quad bandpass filter Semrock FF01-446/510/581/703-25
PMT Thorlabs PMM02
Fiber port Thorlabs PAFA-X-4-A
lens tube Thorlabs SM1L05
Patch cable with 200 um core / 225 um cladding optical fiber with one stripped end and one FC/PC connector Thorlabs Custom
Patch cable with 105 um core / 125 um cladding optical fiber with one stripped end and one FC/PC connector Thorlabs Custom
125 um fiber stripping tool Thorlabs T08S13
225 um fiber stripping tool Thorlabs T10S13
laser fiber adapter OptoEngine FC/PC Adapter
405 nm CW laser at 50 mW OptoEngine MDL-III-405 Distributor for CNI lasers
473 nm CW laser at 50 mW OptoEngine MLL-FN-473-50

Referencias

  1. Teh, S. Y., Lin, R., Hung, L. H., Lee, A. P. Droplet microfluidics. Lab Chip. 8, 198-220 (2008).
  2. Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., Heyman, J. A. Single-cell analysis and sorting using droplet-based microfluidics. Nat Protocol. 8 (5), 870-891 (2013).
  3. Hindson, B. J., Ness, K. D. High-throughput droplet digital PCR system for absolute quantitation of DNA copy number. Anal Chem. 83, 8604-8610 (2011).
  4. Agresti, J. J., Antipov, E. Ultrahigh-throughput screening in drop-based microfluidics for directed evolution. Proc Nat Acad Sci USA. 107 (14), 4004 (2010).
  5. Eastburn, D. J., Sciambi, A., Abate, A. R. Picoinjection Enables Digital Detection of RNA with Droplet RT-PCR. PLOS ONE. 8 (4), (2013).
  6. Cole, R. H., de Lange, N., Gartner, Z. J., Abate, A. R. Compact and modular multicolour fluorescence detector for droplet microfluidics. Lab Chip. 15 (13), 2754-2758 (2015).
  7. Guo, F., Lapsley, M. I. A droplet-based, optofluidic device for high-throughput, quantitative bioanalysis. Anal Chem. 84, 10745-10749 (2012).
  8. . Lithography Available from: https://www.memsnet.org/mems/processes/lithography.html (2015)
  9. DeJournette, C. J., Kim, J., Medlen, H., Li, X., Vincent, L. J., Easley, C. J. Creating Biocompatible Oil-Water Interfaces without Synthesis: Direct Interactions between Primary Amines and Carboxylated Perfluorocarbon Surfactants. Anal Chem. 85 (21), (2013).
  10. Fallah-Araghi, A., Baret, J. C., Ryckelynck, M., Griffiths, A. D. A completely in vitro ultrahigh-throughput droplet-based microfluidic screening system for protein engineering and directed evolution. Lab Chip. 12, 882 (2012).
  11. Eastburn, D. J., Sciambi, A., Abate, A. R. Ultrahigh-Throughput Mammalian Single-Cell Reverse-Transcriptase Polymerase Chain Reaction in Microfluidic Drops. Anal Chem. 85 (16), 8016-8021 (2013).
  12. Martini, J., Recht, M. I., Huck, M., Bern, M. W., Johnson, N. M., Kiesel, P. Time encoded multicolor fluorescence detection in a microfluidic flow cytometer. Lab Chip. 12 (23), 5057-5062 (2012).
  13. Bliss, C. L., McMullin, J. N., Backhouse, C. J. Rapid fabrication of a microfluidic device with integrated optical waveguides for DNA fragment analysis. Lab Chip. 7 (10), 1280-1287 (2007).
  14. Martinez Vazquez, R., Osellame, R. Optical sensing in microfluidic lab-on-a-chip by femtosecond-laser-written waveguides. Anal Bioanal Chem. 393, 1209-1216 (2009).
  15. Vishnubhatla, K. C., Bellini, N., Ramponi, R., Cerullo, G., Osellame, R. Shape control of microchannels fabricated in fused silica by femtosecond laser irradiation and chemical etching. Opt Express. 17 (10), 8685-8695 (2009).
check_url/es/54010?article_type=t

Play Video

Citar este artículo
Cole, R. H., Gartner, Z. J., Abate, A. R. Multicolor Fluorescence Detection for Droplet Microfluidics Using Optical Fibers. J. Vis. Exp. (111), e54010, doi:10.3791/54010 (2016).

View Video